Staten Island · Block 5614 · Lot 12 · 10312

697 Barlow Avenue

2 floors · 1 apartments · 816 sq ft · built 1988 · class A5 · owner of record: Apaf Properties, Llc

35open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
304dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Registered through 2027-09-01

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Aug 22, 2025Boilers CLASS - 2
FOUND CARRIER FURNACE INOPERABLE. DRAIN PIPE FOR FURNACE NO SECURED PROPERLY. DOOR ON FURNACE NOT SECURED PROPERLY, BEING HELD ON WITH TAPE. CIRCUIT BREAKER PANEL IS HANG FROM BOX., MAINTAIN BOILER; CORRECT VIO
#39158135K
Nov 5, 2025
ADMIT/IN-VIO
$0
Aug 11, 2025Construction CLASS - 2
I OBSERVED WATER SUPPLY ROUGH IN CEILING HAS PROHIBITED PEX TUBING AND SHARK-BITE FITTINGS, AS PER PC 605 REMOVABLE JOINTS (SHARK-BITES) ARE PROHIBITED. PEX PLASTIC WATER PIPE IS NOT AN APPROVED MATERIAL, REPAI
#39156598H
Oct 15, 2025
ADMIT/IN-VIO
$0
Aug 7, 2025Unknown CLASS - 3
A8: ELECTRICAL WORK WITHOUT A PERMIT. FOR THE INSTALLATION OF LIGHT FIXTURES, SWITCHES, RECEPTACLES. ON 1ST & 2ND FLOOR. AN APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION IS NOT ON FILE., OBTAIN PERMIT; O
#39156316K
Oct 15, 2025
ADMIT/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (32) · C 3 · B 27 · A 2
IssuedClassViolationCorrect by
Feb 25, 2026CApt 1 · § 27-2028, 2032 ADMIN.CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHFeb 21, 2026
Feb 25, 2026BApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1 LOWER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTHApr 1, 2026
Feb 25, 2026AApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE NORTH WALL AT WALK-IN CLOSET IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1 UPPER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMay 31, 2026
Nov 28, 2025BApt 697 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18121650 ISSUED 29-JUL-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CJan 2, 2026
Nov 24, 2025BApt FLOOR1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT NORTH WALL INSIDE THE CLOSET AT UPPER LEVEL IN THE 2nd ROOM FROM NORTH LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 29, 2025
Nov 24, 2025BApt FLOOR1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL AT LOWER LEVEL IN THE 2nd ROOM FROM NORTH LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 29, 2025
Nov 24, 2025CApt FLOOR1 · § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 22, 2025
Nov 12, 2025BApt FLOOR1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 17, 2025
Nov 5, 2025BApt FLOOR1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 10, 2025
Nov 5, 2025BApt FLOOR1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT SOUTH WALL, EAST WALL AND CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 10, 2025
Nov 3, 2025CApt FLOOR1 · § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 3, 2025
Oct 31, 2025BApt 1 · § 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 5, 2025
Oct 31, 2025BApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT AT CEILING AT UPPER LEVEL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 5, 2025
Oct 31, 2025BApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE NORTH WALL AT CLOSET AT SOUTH AT UPPER LEVEL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 5, 2025
Oct 31, 2025BApt 1 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT WEST WALL AT CLOSET AT EAST IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 5, 2025
Oct 31, 2025BApt 1 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT CEILING AT CLOSET AT EAST IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 5, 2025
Oct 31, 2025BApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE EAST AND SOUTH WALL IN THE FOYER LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 5, 2025
Oct 30, 2025BApt FLOOR1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT FLOOR1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 4, 2025
Oct 29, 2025BApt HOUSE · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT HOUSE, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 3, 2025
Oct 17, 2025BApt 697 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE NORTH WALL AT CLOSET AT SOUTH AT UPPER LEVEL IN THE 1st ROOM FROM NORTH LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 21, 2025
Oct 17, 2025BApt 697 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT WEST WALL AT CLOSET AT EAST IN THE KITCHEN LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 21, 2025
Oct 17, 2025BApt 697 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT CEILING AT CLOSET AT EAST IN THE KITCHEN LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 21, 2025
Oct 17, 2025BApt 697 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE SOUTH WALL AND CEILING IN THE FOYER LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 21, 2025
Oct 6, 2025B§ 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT YARDNov 10, 2025
Oct 1, 2025BApt 697 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL AT LOWER LEVEL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 5, 2025
Sep 26, 2025BApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL AT LOWER LEVEL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHOct 31, 2025
Sep 26, 2025AApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT NORTH WALL INSIDE THE CLOSET AT UPPER LEVEL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 30, 2025
Jul 31, 2025BApt 697 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT THE WEST WALL INSIDE CLOSET AT EAST IN THE KITCHEN LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHSep 4, 2025
Jul 31, 2025BApt 697 · § 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHSep 4, 2025
Jul 31, 2025BApt 697 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE NORTH WALL INSIDE CLOSET AT SOUTH WALL UPPER LEVEL IN THE 1st ROOM FROM NORTH LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHSep 4, 2025
Jul 31, 2025BApt 697 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHSep 4, 2025
Jul 31, 2025BApt 697 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT NORTH WALL INSIDE CLOSET AT SOUTH UPPER LEVEL IN THE 1st ROOM FROM NORTH LOCATED AT APT 697, 1st STORY, 1st APARTMENT FROM WEST AT NORTHSep 4, 2025

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 6:51 PM ET. BBL 5056140012.

Look up another building