20 floors · 102,917 sq ft · built 1931 · class O4 · owner of record: 136 Prop Co Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 46 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 102,917 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $270,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 829 days | Filing window not open yet |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1311). Agency page | Dec 31, 2031 in 1872 days | Next due 2031 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 17, 2024 | Construction CLASS - 2 A.C. 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY AREGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MORE #37028884J | May 26, 2026 DEFAULT | $0 |
| Feb 28, 2023 | Construction CLASS - 2 AC 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FT OR MORE IN #37025371K | Feb 1, 2024 IN VIOLATION | $0 |
| Jul 13, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: AT TIME OF INSPECTION, OBSERVED EGRESS BEING BLOCKED WITH LARGE CASES OF HEAVY-DUTY COMPONENTS AND MULTIPLE PIECES OF HEAVY DUTY PARTS OF MACHINERY PLACED #39065742J | Sep 1, 2022 DEFAULT | $3,125 |
| May 9, 2022 | Construction CLASS - 1 BC3314.10.11 SECURING SUSPENDED SCAFFOLD SS SHALL BE LOWERED TO STREET OR DECK OF SWS AT END OF SHIFT OR IN ACCORDANCE WITH DESIGN DRAWINGS.NOTE:AT TIME OF INSPECTION OBSERVED SUSPENDED SCAFFOLD AT ROOF LOCATIO #35593081P | Oct 20, 2022 DEFAULT | $6,250 |
| May 9, 2022 | Construction CLASS - 1 BC3301.1.3 MANUFACTURE SPECIFICATIONS.NOTE:AT TIME OF INSPECTION OF 19 STORY BUILDING OBSERVED WORK IN PROGRESS ON SUSPENDED SCAFFOLD REQUEST RIGGING FORMAN FOR SPECS ON WOODEN PLATFORM & MOTORS IN USE NONE WER #35593082R | Oct 20, 2022 DEFAULT | $6,250 |
| Sep 16, 2021 | Construction CLASS - 1 STEEL ASSEMBLY/FOUNDATION(STRUCTURAL)NOTE:AT THE TIME OF INSPECTION OFAN ALT 2 FACADE JOB IN PROGRESS I OBSERVED/STEEL CONNECTIONS/ASSEMBLY MODIFIED FROM ROOF LEVEL TO BULKHEAD SHOP DRAWINGS THAT WERE PROVIDED #35580368J | May 25, 2023 IN VIOLATION | $2,500 |
| Sep 16, 2021 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED DOCUMENT-CD-5 AT THE TIME OF MY INSPECTION OF AN ALT-2 ACTIVE JOBSITE I OBSERVED OUTRIGGERS SET UP ON STEEL FRAME ON ROOF TOP.UPON INSPECTION OF THE APPROVED CD-5 DOCUMENTS IT #35580364M | May 25, 2023 IN VIOLATION | $2,500 |
| Sep 16, 2021 | Construction CLASS - 1 BC 3314.15.2 PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD ISSUED PERSUANT TO 28-207.2 ALL FACADE WORK(EXTERIOR WORK)NOTE:AT TIME OF INSPECTION I OBSERVED SUSPENDED SCAFFOLD IN PLACE AND IN USE READY AVAILABLE #35580366X | May 25, 2023 IN VIOLATION | $2,500 |
| Sep 16, 2021 | Cranes and Derricks CLASS - 1 FAILURE TO PERFORM SAFE/PROPER INSPECTION OF SUSPENDED SCAFFOLD.NOTE:AT TIME OF INSPECTION OF A ALT 2 FACADE JOB IN PROGRESS OBSERVED SUSPENDED SCAFFOLD IN PLACE AND IN USE AT EXPO#1,2,3 AND 4 WITH THE FOLLOWIN #35580367H | May 25, 2023 IN VIOLATION | $10,000 |
| Sep 16, 2021 | Construction CLASS - 1 SUPPORTED SCAFFOLD AT THE TIME OF MY INSPECTION OF AN ALT 2 FACADE JOBIN PROGRESS I OBSERVED SUPPORTED SCAFFOLD IN PLACE AT EXP#2 ON THE 16TH,17TH,18TH,20TH AND 21ST FLOOR SET BACKS.THE FOLLOWING OBJECTIONS WER #35580370Z | May 25, 2023 IN VIOLATION | $2,500 |
| Sep 16, 2021 | Construction CLASS - 2 WORK DOES NOT CONFORM TO APPROVED/ACCEPTED DWGS-SIDEWALK SHED.AT THE TIME OF MY INSPECTION OF AN ALT 2 FACADE JOB IN PROGRESS I OBSERVED A SIDEWALK SHED IN PLACE AT EXP#1 AND 2 UNDER PERMIT#M0038527-I1-SH.UPON #35580369L | Apr 28, 2022 IN VIOLATION | $625 |
| Mar 30, 2021 | Construction CLASS - 2 SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BLDG 100 FEET OR MORE IN HEIG #37020974R | Oct 21, 2021 IN VIOLATION | $0 |
| Jan 27, 2021 | Unknown CLASS - 2 FAILURE TO POST AND DISTRIBITE NOTICE TO OCCUPANTS OF TPP AT THE TIME OF MY INSPECTION ON AN ACTIEV JOBSITE OF AN OCCUPIED 19 STORY BUILDING OBSERVED FACADE WOR IN PROGRESS WITH INSTALLED SUSPENDED SCAFFOLD INS #35545755X | Jul 22, 2021 IN VIOLATION | $1,250 |
| Jan 16, 2020 | Elevators CLASS - 1 42-M-07 NO DOOR MONITORING INSTALLED IN THIS CONTROLLER AS MANTATED BY3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATUREWHICH ENSURES PASSENGER SAFETY.REMEDY; FILE APPLICATION INSTALL DLM #38273024P | Oct 15, 2020 IN VIOLATION | $0 |
| Nov 15, 2019 | Construction CLASS - 2 A.C. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLER AN DFILE SPRINKLER REPORT PREOPARED BY A REGISTERED DESIGN PROFESSIONAL BY JULY 1, 2019 IN AN OFFICE BUILDING 100 FEET #37016647H | Jul 2, 2020 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 3, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF00609 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
None open.