Manhattan · Block 1377 · Lot 16 · 10065

694 Madison Avenue

5 floors · 9 apartments · 11,050 sq ft · built 1879 · class C7 · owner of record: Mbs Real Estate Group, Llc

28open violations
$0ECB/OATH penalties owed
14HPD class C (immediately hazardous)
61dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 61 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 61 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 61 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-05-09 (Accepted). Agency page

Dec 31, 2026
in 61 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 77 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 305 days
Registered through 2027-09-01

Open violations

ECB / OATH (0)

None open.

DOB (3)
IssuedViolationStatus
Jul 30, 2026CONSTRUCTION
ST&DM WORK @5-STY WOOD FRAME BLDG.SEPARATION @EXP3 MASONRY BRICK VENEER @5FL ADJ TO EXP4 PARTY WALL W/4"LEAN.MASONRY WALL OUT OF PLUMB @3,4&5FL.REPORT RECS MONITORING TO STBLZ REAR WALL.REMEDY:PROVIDE MONITORING PROTOCOL BY 8/5/26.SUBMIT REPORTS WEEKLY.SUBMIT FIRST REPORT BY 8/7/26
#CE10801JT
DOB VIOLATION - ACTIVE
Feb 26, 2014LANDMARK

#14-0678
DOB VIOLATION - ACTIVE
Mar 22, 1995CONSTRUCTION

#08M01
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 8)
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
HPD (23) · C 14 · B 8 · A 1
IssuedClassViolationCorrect by
Apr 29, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 2, 2026
Aug 2, 2022CApt 4R · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 2, 2022
Jul 26, 2022C§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT STAIR BULKHEAD TO THE ROOF , 5th STORYAug 9, 2022
Jul 26, 2022CApt 5F · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM NORTH AT EASTJul 26, 2022
May 19, 2022CApt 4R · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMay 19, 2022
May 19, 2022CApt 4R · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMay 25, 2022
Apr 30, 2018BApt 3N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3N, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJun 4, 2018
Apr 30, 2018BApt 3N · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3N, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJun 4, 2018
May 17, 2017CApt 3N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 3N, 3rd STORY, APARTMENT AT NORTHMay 25, 2017
May 17, 2017CApt 3N · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN LOCATED AT APT 3N, 3rd STORY, APARTMENT AT NORTHMay 25, 2017
Jun 24, 2008CApt 4R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AT BATHROOM OF 4 STY SOUTHWEST APT 4R ER1. , SECTION '' ''Jun 30, 2008
Jun 24, 2008CApt 4R · SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB 4 STY SOUTHWEST APT 4R ER1. , SECTION '' ''Jun 30, 2008
Jun 24, 2008CApt 4R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM OF 4 STY SOUTHWEST APT 4R ER1. , SECTION '' ''Jun 30, 2008
May 4, 2007CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED.May 27, 2007
May 4, 2007BSECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS REAR YARDJun 25, 2007
May 4, 2007BSECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER INSTALLED PARTY WALL BALCONY 4 STY FRONTJun 25, 2007
May 4, 2007BSECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING FLOWER POTS PARTY WALL BALCONY 4 & 5 STY FRONTJun 25, 2007
May 4, 2007CSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEET METAL CORNICE CORRODED & FRAGMENTED AT 3 STY EAST EXTERIOR WALL OF BLDG ER1May 27, 2007
May 4, 2007CApt 3F · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE 3 STY PARTY WALL BALCONY NORTH PORTION CRACKED AT EAST EXTERIOR WALL OF BLDG NEAR 3 STY EAST APT 3F ER1 LOCATED AT APT 3FMay 27, 2007
May 4, 2007BApt 4R · SECTION 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 4 STY SOUTH APT 4R. , SECTION '' ''Jun 25, 2007
May 4, 2007CApt 3N · SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN AND BATHROOM FIXTURES 3 STY NORTH APT 3N. LOCATED AT APT 3NMay 27, 2007
May 4, 2007BApt 3N · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 3 STY NORTH APT 3N JAHSS. LOCATED AT APT 3NJun 25, 2007
May 4, 2007BApt 5F · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 5 STY EAST APT 5F PORTNOY. , SECTION '' ''Jun 25, 2007

Issued in the last 120 days

DateSourceWhatNow
Jul 30, 2026DOBCONSTRUCTION: ST&DM WORK @5-STY WOOD FRAME BLDG.SEPARATION @EXP3 MASONRY BRICK VENEER @5FL ADJ TO EXP4 PARTY WALL W/4"LEAN.MASONRY WALL OUT OF PLUMB @3,4&5FL.REPORT RECS MONITORING TO STBLZ REAR WALL.REMEDY:PROVIDE MONITORING PROTOCOL BY 8/5/26.SUBMIT REPORTS WEEKLY.SUBMIT FIRST REPORT BY 8/7/26Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 6:20 PM ET. BBL 1013770016.

Look up another building