3 floors · 2 apartments · 4,095 sq ft · built 1929 · class K4 · owner of record: Palvin Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 312 days | Required only if the owner doesn't live there |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1164 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 3, 2008 | Construction Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL. NOTE: BRICK WALL CRACKED & BULGING AT GRADE LEVEL AT 1ST FL AT WINDOW AREA AT SIDE OF BLDG ADJACENT TO ENTRANCE. BRICK WORK CRACKED & MORTAR JOINTS MISSING AT 1 STORY #34640257M | Jun 2, 2008 IN VIOLATION | $0 |
| Dec 6, 2006 | Boilers Non-Hazardous 18A,B,48B,50A,B.50A SAFETY VALVE LEAKING.50B REPLACE FLU PIPE NEAR BOILER SHOWS EVIDENCE OF PREMATURE CORROSION. #32050362L | Sep 22, 2008 WRITTEN OFF | $0 |
| Nov 1, 2000 | Boilers Hazardous 36,49,51.INSTALL 2 MANUAL RESET TYPE LOW WATER CUTOUT ON THIS BOILER COLUMBIA NAT'L BD #137337 YEAR 1997.BOILER SEALED DO NOT USE. #32021011R | Feb 12, 2001 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 6, 2006 | BOILER #47816-01 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 19, 2008 | B | SECTION 27-2032, 2034 ADNIM. CODE: DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM GAS STEAM RADIATOR, CENTER ROOM AND GAS HOT WATER HEATER, KITCHEN - 2ND STY., | Sep 23, 2008 |