| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 45,864 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 182 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 182 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 426 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-11 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 4, 2026 | Construction CLASS - 2 I OBSERVED IN THE CELLAR 3 COMMERCIAL GAS FIRED DRYERS INSTALLED WITHOUT PERMITS ON FILE WITH THE DEPARTMENT OF BUILDINGS. AS PER AC 28-105.1 IT SHALL BE UNLAWFUL TO ERECT, INSTALL, ALTER OR REPLACE ANY GAS, ME #39187006R | Jun 3, 2027 DEFAULT | $6,250 |
| May 4, 2026 | Construction CLASS - 2 OBSERVED 3 GAS-FIRED DRYERS INSTALLED IN BASEMENT, WITHOUT SPRINKLER SYSTEM AS PER 903.2.11.13 BC LAUNDRY DRYING AREAS. AN AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED IN SPACES IN WHICH TWO OR MORE CLOTHES DR #39187007Z | Jun 3, 2027 DEFAULT | $6,250 |
| May 4, 2026 | Construction CLASS - 2 OBSERVED PROHIBITED FLEXIBLE CONNECTORS INSTALLED ON 3 GAS-FIRED COMMERCIAL CLOTHES DRYERS AS PER PPN DATED 1994 "PLEASE SEE DOCUMENT IN THE EVIDENCE PACKAGE". ADDITIONALLY, THE COMMERCIAL DRYERS EXHAUST DUCTWO #39187008K | Jun 3, 2027 DEFAULT | $6,250 |
None open.