6 floors · 124 apartments · 132,750 sq ft · built 1951 · class D4 · owner of record: Cromwell Ownrs Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 62 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 62 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 78 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 132,750 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 183 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 183 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2214). Agency page | Dec 31, 2034 in 2984 days | Next due 2034 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-03 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #00777 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 28, 2024 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT NORTH WALL AT PUBLIC HALL, 6th STORY | Oct 1, 2024 |
| Jun 28, 2024 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT NORTH WALL AT PUBLIC HALL, 6th STORY | Aug 2, 2024 |
| Sep 28, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONERS PROTUDING BEYOND WINDOW SILLS AT 6TH,5TH AND,2ND STORY BALCONYS , SECOND STACK FROM SOUTH AT EAST | Nov 2, 2020 |
| Sep 28, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONERS PROTUDING BEYOND WINDOW SILLS AT 6TH, 5TH ,3RD ,2ND, AND ,1ST STORY BALCONYS , FIRST STACK FROM SOUTH AT EAST | Nov 2, 2020 |
| Sep 28, 2020 | B | Apt 707 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 707, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST | Nov 2, 2020 |
| Jul 11, 2013 | A | Apt 606 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Dec 13, 2013 |
| Jul 11, 2013 | A | Apt 606 · SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1ST WINDOW FRAME FROM EAST AT SOUTH IN THE 2nd ROOM FROM NORTH LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Dec 13, 2013 |
| Jul 11, 2013 | A | Apt 606 · SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 2ND WINDOW FRAME FROM NORTH AT EAST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Dec 13, 2013 |
| Jul 11, 2013 | B | Apt 606 · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Sep 14, 2013 |
| Jul 11, 2013 | B | Apt 606 · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Sep 14, 2013 |
| Jul 11, 2013 | A | Apt 606 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Dec 13, 2013 |
| May 22, 2013 | A | Apt 606 · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM NORTH AT WEST, THE 5th ROOM FROM NORTH AT WEST, THE KITCHEN , THE 2nd ROOM FROM NORTH LOCATED AT APT 606, 6th STORY, 4th APARTMENT FROM NORTH AT EAST | Aug 25, 2013 |
| Dec 29, 2011 | B | Apt 606 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Feb 2, 2012 |
| Dec 29, 2011 | B | Apt 606 · SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Feb 2, 2012 |
| Dec 29, 2011 | B | Apt 606 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 606, 5th STORY, 4th APARTMENT FROM NORTH AT EAST | Feb 2, 2012 |
| Jun 24, 2008 | B | Apt B17 · D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE CELLAR APT B17. LOCATED AT APT B17 | Jul 29, 2008 |
| Jun 24, 2008 | B | D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AT FRONT THE SOUTH STACK AT 1 2 5 & 6 STYS AIR CONDITIONERS PROTRUDING FROM WINDOW. | Jul 29, 2008 |
| Jun 24, 2008 | B | D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AT FRONT THE NORTH STACK AT 1 2 5 & 6 STYS AIR CONDITIONERS PROTRUDING FROM WINDOWS. | Jul 29, 2008 |
| Jun 24, 2008 | B | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE EAST DOOR TO ROOF PUB HALL BULKHEAD NORTH SECTION R117. | Jul 29, 2008 |
| Jun 24, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE TERRA COTTA WALLS METER ROOM SUB CELLAR NEAR WATER TANK R126. | Jul 29, 2008 |
| Jun 24, 2008 | B | Apt B17 · D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING CELLAR APT B17. LOCATED AT APT B17 | Jul 29, 2008 |
| Jun 24, 2008 | B | Apt 216 · D26-10.01 ADM CODE ABATE THE NUISANCE CONSISTING OF KEY LOCK ON FIRE ESCAPE WINDOW 1 STY APT 216. , SECTION '' '' | Jul 29, 2008 |
| Jun 24, 2008 | B | Apt 216 · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE OPENING BETWEEN WOOD FLOOR & BASE MOULDING AT 2 STY SOUTH SECTION SOUTH APT 216 SOUTH EAST & WEST ROOMS. , SECTION '' '' | Jul 29, 2008 |
| Jun 24, 2008 | A | D26-21.03 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALL OPPOSITE WEST PUBLIC HALL STAIRS ALL STYS NORTH SECTION. | Sep 27, 2008 |
| Aug 28, 2007 | B | Apt 419 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PEELING PAINT AT BATHTUB IN THE BATHROOM LOCATED AT APT 419, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 2, 2007 |
| Aug 28, 2007 | B | Apt 419 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 419, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 2, 2007 |
| Aug 28, 2007 | A | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING | Dec 1, 2007 |
| Aug 28, 2007 | B | Apt 410 · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 4 STY APT 410. , SECTION '' '' | Oct 2, 2007 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)