2 floors · 2 apartments · 1,740 sq ft · built 2005 · class B2 · owner of record: Vann, Mary M
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 22, 2019 | Construction CLASS - 1 I OBSERVED IN THE CELLAR AREA NEWLY INSTALLED GAS PIPING FOR A GAS DRYER. ALL THE GAS WORK AND INSTALLATION WAS DONE WITHOUT A PERMIT.. WORK WAS A 100% COMPLETED., OBTAIN PERMIT #39011564M | May 12, 2020 IN VIOLATION | $0 |
| Oct 22, 2019 | Plumbing CLASS - 1 I OBSERVED IN THE CELLAR AREA SEVERAL FEET OF GAS PIPING REPLACED FOR A GAS DRYER. NO RECORDS AT DOB OF ANY TEST OR INSPECTIONS BEING PERFORMED ON THE NEW OR ALTERED SYSTEM.., PERFORM TEST #39011565Y | May 12, 2020 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 5, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #01300 | DOB VIOLATION - ACTIVE |
| Feb 5, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #01301 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Feb 5, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 5, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 28, 2014 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ELECTRIC OUTLETS NORTHWALL IN THE KITCHEN. LOCATED AT APT 2, 2nd STORY | Sep 1, 2014 |
| Jul 28, 2014 | A | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE SINK CABINET IN THE KITCHEN LOCATED AT APT 2, 2nd STORY | Oct 31, 2014 |
| Jul 28, 2014 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC OUTLETS IN THE WEST BATHROOM LOCATED AT APT 2, 2nd STORY | Sep 1, 2014 |
| Jul 28, 2014 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING COVERS FOR ELECTRIC OUTLETS IN BOTH SOUTHEAST AND SOUTHWEST BEDROOMS. LOCATED AT APT 2, 2nd STORY | Sep 1, 2014 |
| Jul 28, 2014 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ELECTRIC OUTLETS SOUTH WALL IN THE SOUTHWEST BEDROOM LOCATED AT APT 2, 2nd STORY | Sep 1, 2014 |
| Jul 28, 2014 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC OUTLETS IN THE EAST BATHROOM LOCATED AT APT 2, 2nd STORY | Sep 1, 2014 |
| Jul 28, 2014 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ALL BASEBOARD RADIATORS COVERS. LOCATED AT APT 2, 2nd STORY | Sep 1, 2014 |
| Jul 28, 2014 | A | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WEST WALL NEAR STAIRS IN THE LIVING-ROOM. LOCATED AT APT 2, 2nd STORY | Oct 31, 2014 |
| Jul 28, 2014 | B | Apt 2 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Sep 1, 2014 |