2 floors · 1 apartments · 1,700 sq ft · built 1931 · class S1 · owner of record: Vasili Tsaknis Irrevocable Trust
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 310 days | Required only if the owner doesn't live there |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 431 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 1, 2013 | Boilers CLASS - 2 B254,3A,44A,48A,50,50A,50B,50C. 50-BOTH PRESSURE CONTROLS ON THE SAME1/4 PIPE TO BOILER; 50A-BOILER WATER FEED DIRECT INTO CASTIRON BOILER;50B-BOILER SAFETY VALVE DISCHARGE PIPE MADE OF PLASTIC; 50C-HOT WATER #32073564L | Aug 19, 2013 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 9, 1990 | BOILER 42C/38/18B/6A PROVIDE PROPER SUPPORT FOR BOILER BREECHING-NO COVERS ON ELECTRICAL CONTROLS-DIRTY BOILER SECTION #32004907P | VIOLATION UNSERVED ECB-ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 7:53 PM ET. BBL 3055760047.