| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 27,324 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 801 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 16, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SIDEWALK SHED AND NEEDLE BEAMS INSTALLED AT EXPOS 1&4. UPON REQUEST TO SEE THE INSTALLATION COMPLETION LETTER FOR THE SIDEWALK SHED AS WELL AS THE NEEDLE BEAMS (DOCUMENTS TO BE KEPT #39560673N | Dec 23, 2026 PENDING | $1,250 |
| Oct 16, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A SIDEWALK SHED AND FENCE INSTALLED AT EXPOS 1&4 WITH NO CORNER AND BLIND SPOT MIRRORS INSTALLED AT THE REQUIRED LOCATIONS. VIEW IS OBSTRUCTED BY TEMP CONSTRUCTION EQUIPMENT AT THE C #39560675R | Dec 23, 2026 PENDING | $2,400 |
| Oct 16, 2026 | Unknown CLASS - 1 UPON INSPECTION OF A 9 STORY NB I OBSERVED A SETBACK ON THE 2ND FLOOR AT EXPOS 3 WITH A PLYWOOD BARRIER/GUARDRAIL SYSTEM INSTALLED ABOVE THE EXPOS 3 ADJOINING PROPERTY CONTRARY TO THE SSP WITH NO OVERHEAD PROTE #39560670H | Dec 23, 2026 PENDING | $10,000 |
| Oct 16, 2026 | Construction CLASS - 2 UPON INSPECTION OF A 9 STORY NB I OBSERVED WORK CONTRARY TO THE SITE SAFETY LOGISTICS PLAN. ON GOING ROOF/BULKHEAD WORK ABOVE THE ADJOINING PROPERTY AT EXPOS 2 AND ONGOING EXTERIOR WORK/EQUIPMENT PLACED WITHIN #39560663J | Dec 23, 2026 PENDING | $1,250 |
| Jul 21, 2026 | Unknown CLASS - 2 BC3303.16 WORKER SHED: DURING INSPECTION OF A 9 STORY BUILDING I OBSERVED A WORKERS SHED WITHIN THE SITE OFF OF THE HOIST. THE PLYWOOD USED TO ENCLOSE IT WAS PAINTED GREEN. PLYWOOD USED MUST CLEARLY INDICATE TH #39556869N | Apr 19, 2027 | $2,500 |
| Jul 21, 2026 | Construction CLASS - 1 DURING INSPECTION OF A 9 STORY BUILDING, I OBSERVED INADEQUATE HOUSEKEEPING THROUGHOUT THE SITE. THERE WAS MATERIAL IN THE WALKWAY, BLACK GARBAGE BAG, FOOD CONTAINERS, CONSTRUCTION MATERIAL, WATER AND DEBRIS ON #39556868L | Apr 19, 2027 | $2,500 |
| Jul 21, 2026 | Construction CLASS - 2 DURING INSPECTION OF A 9 STORY BUILDING I OBSERVED THAT THERE WAS STUCCO/STYROFOAM DEBRIS BLOWING AROUND THE EXTERIOR PERIMETER, WITHIN THE STREET, THE ADJACENT PROPERTIES YARDS, AND IN THE SEWER DRAINS. THE DE #39556870K | Apr 19, 2027 | $5,000 |
| Jun 8, 2026 | Unknown CLASS - 1 PROPOSED 9STORY NB CURRENTLY FORMING ROOF LEVEL. OBSERVED ACTIVE SITE WITH INADEQUATE FIRE EXTINGUISHERS. NOTED DEPLETED LEVELS, INSPECTIONS WERE OUT OF DATE AND MISSING INSPECTION TAGS. ALSO NOTED WORKER PERFO #39555215J | Apr 16, 2027 | $1,250 |
| Jun 8, 2026 | Unknown CLASS - 1 ACTIVE 9STORY NB. OBSERVED SUPPORTED SCAFFOLD INSTALLED ATOP 7TH FLOOR SETBACK AT CORNER OF EXPO1&4. SUPPORTED SCAFFOLD WAS UNSAFELY SUPPORTED. SF WAS ON UNSAFE FOUNDATION; ONE LEG POST WAS SEEN DISLODGED/FLOAT #39555216L | Apr 16, 2027 | $5,000 |
| Mar 5, 2026 | Construction CLASS - 2 UPON INSPECTION OF A NON ACTIVE PROPOSED 7 STORY NB I OBSERVED PEDESTRIAN PROTECTION ( YODOCK BARRIERS) INSTALLED CONTRARY TO CODE 3303.8.2 FREE FROM OBSTRUCTION. BARRIERS INSTALLED IN STREET DIRECTLY INFRONT T #39551317M | Dec 18, 2026 | $2,400 |
| Mar 5, 2026 | Unknown CLASS - 2 UPON INSPECTION I OBSERVED VIDEO CAMERAS INSTALLED ON 2X4S AT EXPOS 1 AND 4 HANGING OVER THE PEDESTRIAN SIDEWALK. EQUIPMENT HANGING OVER THE SIDEWALK WITHOUT OVERHEAD PROTECTION IN A POTENTIAL OVERHEAD HAZARD. #39551319X | Dec 18, 2026 | $2,500 |
| Mar 5, 2026 | Construction CLASS - 2 UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOSURES 1&4 WITH NO FENCE PROJECT INFO PANELS INSTALLED AT EXPOS 1&4 CONTRARY TO CODE 3301.9.1 FENCE PROJECT INFORMATION PANEL. WHERE A SITE IS ENCLOSED WITH A #39551316K | Dec 18, 2026 | $1,250 |
| Feb 19, 2026 | Construction CLASS - 2 VIOLATION #039548470L RE-INSPECTED. NO CERTIFICATE OF COMPLIANCE ON RECORD AT TIME OF INSPECTION. SITE CLOSED; NO ACCESS OBTAINED. VIOLATION REMAINS OPEN AND NOT CORRECTED. #39550577Y | Jan 12, 2027 | $1,250 |
| Jan 19, 2026 | Unknown CLASS - 2 UPON INSPECTING THE EXTERIOR OF THE SITE. OBSERVED ICE BUILD UP AND SLIPPERY UNSAFE CONDITIONS AROUND THE SITE. PEDESTRIANS ARE FORCED TO WALK IN THE STREET DUE TO CONCERN OF SLIPPING AND INJURIES. B.C 3303.4.1 #39549306Y | Nov 2, 2026 | $2,500 |
| Jan 19, 2026 | Unknown CLASS - 2 SITE IS IN FOUNDATION PHASE OBSERVED OVER 2 FT OF STANDING WATER WITH NO DRAINAGE OR PUMPING SYSTEM INSTALLED TO DEWATER THE SITE. BC 3303.14.2, FAILURE TO PREVENT WATER ACCUMULATION CAN JEOPARDIZED FOUNDATION #39549305M | Nov 2, 2026 | $2,500 |
| Dec 24, 2025 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED FOUNDATION CONTAINING OVER 2 FT OF STANDING WATER WITH NO DRAINAGE OR PUMPING PROVIDED. CONTRARY TO BC 3303.14.2, FAILURE TO PREVENT WATER ACCUMULATION JEOPARDIZED FOUNDATION STA #39548470L | Jan 12, 2027 DEFAULT | $2,530 |
| Dec 24, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION, OBSERVED CONSTRUCTION SITE EXCEEDING 6 000 SQ FT WITH NO REQUIRED WATCHPERSON ON DUTY DURING NON-WORKING HOURS. CONTRARY TO BC 3303.3, FAILURE TO PROVIDE COMPETENT WATCHPERSON COMPROMISED #39548471N | May 13, 2027 PENDING | $2,500 |
| Nov 4, 2025 | Unknown CLASS - 2 FAILURE TO DRAIN CONSTRUCTION SITE OF STANDING WATER. B.C 3303.14.2 SITE IS IN FOUNDATION PHASE AND OBSERVED WATER ACCUMULATED OVER 2' DEEP. CREATING UNSAFE CONDITIONS AND POSSIBLE WATER DAMAGE TO THE FOUNDATIO #39546646R | Jan 21, 2027 | $2,500 |
| Jul 5, 2025 | Construction CLASS - 2 ACTIVE DOT PERMIT TO OCCUPY STREET OBSERVED JERSEY BARRIERS AT EXP# 1 4 NOT INSTALLED AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS NOT INTERLOCKED NEITHER FILLED SAND/WATER AND OBSTRUCTION FIRE HYDRANT. #39541990N | Nov 17, 2026 | $1,250 |
| Jul 5, 2025 | Construction CLASS - 2 OBSERVED CONSTRUCTION FENCE INSTALLED NOT MAINTAINED AS PER CODE CONSTRUCTION FENCE COVERED WITH GRAFFITI AND POSTERS AND SHARP OBJECT PROTRUDING. #39541995M | Nov 17, 2026 | $1,000 |
| Jul 5, 2025 | Unknown CLASS - 2 BC3303.3 WATCHPERSON. OBSERVED 7 STORY NEW BUILDING, BUILDING APPROXIMATELY 6612 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALE #39541992R | Nov 17, 2026 PENDING | $2,500 |
| Jan 21, 2025 | Unknown CLASS - 2 FAILURE TO DRAIN CONSTRUCTION SITE OF STANDING WATER: AS NOTED AT TIMEOF MY INSPECTION AT THE ABOVE SITE AT FOUNDATION LEVEL OBSERVED APPROX30'X40' FOUNDATION WITH ABOUT 12" OF STANDING WATER ON SITE THIS STAND #35689702P | Dec 8, 2026 | $5,000 |
| Jan 21, 2025 | Construction CLASS - 2 PROJECT INFORMATION PANEL CONSTRUCTION SIGN NOT PROVIDED OR NOT INCOMPIANCE WITH SECTION. AS NOTED AT TIME OF MY INSPECTION OBSERVED THAT THERE WAS NO PROJECT INFORMATION PLACE ON SITE AS PER SECTION AT NAME OF #35689703R | Dec 8, 2026 | $3,125 |
| Issued | Violation | Status |
|---|---|---|
| Oct 24, 2008 | CONSTRUCTION #0102AM | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 16, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 16, 2026 | ECB | Construction: UPON INSPECTION I OBSERVED A SIDEWALK SHED AND NEEDLE BEAMS INSTALLED AT EXPOS 1&4. UPON REQUEST TO SEE THE INSTALLATION COMPLETION LETTER FOR THE SIDEWALK SHED AS WELL AS THE NEEDLE BEAMS (DOCUMENTS TO BE KEPT | Open |
| Oct 16, 2026 | ECB | Construction: UPON INSPECTION I OBSERVED A SIDEWALK SHED AND FENCE INSTALLED AT EXPOS 1&4 WITH NO CORNER AND BLIND SPOT MIRRORS INSTALLED AT THE REQUIRED LOCATIONS. VIEW IS OBSTRUCTED BY TEMP CONSTRUCTION EQUIPMENT AT THE C | Open |
| Oct 16, 2026 | ECB | Unknown: UPON INSPECTION OF A 9 STORY NB I OBSERVED A SETBACK ON THE 2ND FLOOR AT EXPOS 3 WITH A PLYWOOD BARRIER/GUARDRAIL SYSTEM INSTALLED ABOVE THE EXPOS 3 ADJOINING PROPERTY CONTRARY TO THE SSP WITH NO OVERHEAD PROTE | Open |
| Oct 16, 2026 | ECB | Construction: UPON INSPECTION OF A 9 STORY NB I OBSERVED WORK CONTRARY TO THE SITE SAFETY LOGISTICS PLAN. ON GOING ROOF/BULKHEAD WORK ABOVE THE ADJOINING PROPERTY AT EXPOS 2 AND ONGOING EXTERIOR WORK/EQUIPMENT PLACED WITHIN | Open |
| Jul 21, 2026 | ECB | Unknown: BC3303.16 WORKER SHED: DURING INSPECTION OF A 9 STORY BUILDING I OBSERVED A WORKERS SHED WITHIN THE SITE OFF OF THE HOIST. THE PLYWOOD USED TO ENCLOSE IT WAS PAINTED GREEN. PLYWOOD USED MUST CLEARLY INDICATE TH | Closed |
| Jul 21, 2026 | ECB | Construction: DURING INSPECTION OF A 9 STORY BUILDING, I OBSERVED INADEQUATE HOUSEKEEPING THROUGHOUT THE SITE. THERE WAS MATERIAL IN THE WALKWAY, BLACK GARBAGE BAG, FOOD CONTAINERS, CONSTRUCTION MATERIAL, WATER AND DEBRIS ON | Closed |
| Jul 21, 2026 | ECB | Construction: DURING INSPECTION OF A 9 STORY BUILDING I OBSERVED THAT THERE WAS STUCCO/STYROFOAM DEBRIS BLOWING AROUND THE EXTERIOR PERIMETER, WITHIN THE STREET, THE ADJACENT PROPERTIES YARDS, AND IN THE SEWER DRAINS. THE DE | Closed |