22 floors · 221 apartments · 213,660 sq ft · built 1969 · class D6 · owner of record: Nyc Housing Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 213,660 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1154 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1241). Agency page | Dec 31, 2031 in 1884 days | Next due 2031 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | On file | Cycle 10 filing on record: UNSAFE (2025-08-04) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 8, 2025 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED AT THE ADDRESS 201 WEST 93 STREET SIDEWALK SHED AT EXPOSURE 1,2,3 & 4 WAS REMOVED WITHOUT THE AUTHORIZATION FROM THE DOB, THIS IS CONTRARY TO THE APPROVED SITE SAFETY PLAN OR #39544561Z | Nov 13, 2025 ADMIT/IN-VIO | $0 |
| Aug 13, 2025 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION, SIDEWALK SHED WAS BEING REMOVED FROM EXPOSURES 1 AND 4 OF A 22 STORY DETACHED OCCUPIED BUILDING WITH OUT THE SITE SAFETY MANAGER ON SITE, NO FLAGGERS WHERE PRESENT WHILE EQUIPMENT #39543658K | Nov 10, 2026 | $10,000 |
| Apr 23, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE OR APPURTENANCES. NOTE:ATTIME OF INSPECTION OBSERVED 1)CRACKED-BROKEN SOFFIT SECTIONS AT CORNICE ON ALL EXPOSURES#1&2&3&4. 2)BROKEN WINDOW PANEL GLASS AT 22ND FL,EXP #35560016H | Jul 29, 2021 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) CYCLE 9 FAILURE TO CORRECT SWARMP CONDITIONS #00020 | DOB VIOLATION - ACTIVE |
| Jan 23, 2025 | HAZARDOUS CONDITION (FACADE) NYCHA CYCLE 9C UNSAFE REPORT FILED #912005 | DOB VIOLATION - ACTIVE |
| Apr 5, 2019 | NYCHA ELEV ANNUAL INSPECTION/TEST VIO ISSUED TO NYCHA ELEVATOR-FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST #00002 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01018 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | Facades FISPFCS CYCLE 9 FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Jan 23, 2025 | Facades FISPHAZ NYCHA CYCLE 9C UNSAFE REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 20, 2015 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CLOSET NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILE FLOOR IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILE FLOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jan 20, 2015 | B | Apt 6G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 24, 2015 |
| Jul 20, 2007 | B | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM REQUIRED | Aug 24, 2007 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 9:39 AM ET. BBL 1012410025.