| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 13, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39127566K, FILE A CERTIFICATE OF CORRECTION #39166892H | Mar 1, 2027 DEFAULT | $6,250 |
| Nov 13, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39127567M, FILE A CERTIFICATE OF CORRECTION #39166891X | Jan 11, 2027 DEFAULT | $6,250 |
| Oct 16, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. AT TIME OF INSPECTION, OBSERVED LARGE OPENINGS AND GAPS THROUGHOUT THE BUILDING ON THE WALLS AND CEILINGS ON ALL FLO #39127566K | Feb 10, 2025 IN VIOLATION | $0 |
| Oct 16, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLAINT MANNER. AT TIME OF INSPECTION, OBSERVED EXCESSIVE MOLD BUILD UP IN THE CELLAR ROOMS AND 1ST FLOORS HALLS, LARGE OPENINGS/HOLES OBSERVED ON SHEETROCK INTERIOR WAL #39127567M | Feb 10, 2025 IN VIOLATION | $0 |
| Jun 18, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE: METAL CORNICE AT 3RD STORY ROOF AREA IS ROTTEN WITH LANGE HOLES AND SAGGING AT FRONT EXPSOURE 1 CREATING A HAZARDOUS CONDITON TO SIDEWALK AND WALK #35315265J | Aug 20, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 6, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION AT EXP1,OBSERVED DEFECTIVE CONDITIONS SUCH AS CRACKS IN STU CCO,SPALLING AT PARAPET LEVEL.OBSERVED CRACKS IN STONE AROUND 1ST FL S IGN LEANING TOWARDS PUBLIC.AT EXP2 OBSERVED SECTION OF STUCCO MISSING, EXPOSING BRICK I #SR30502DO | DOB VIOLATION - ACTIVE |
| Jun 6, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO HAZARDOUS MATERIAL.OBSERVED AT EXP1 CRACKS SPALLING STUCCO AT PARAPET LEVEL.MISSING AND DAMAGED MORTAR JOINTS IN BRICK AND STONE.OBSERVED CRACKED STONE AND LOOSE SIGN LEANING TOWARDS THE PUBLIC.THESE CONDITIONS ARE ON PENNSYLVANIA AVE EAST ELEV EXP1.REM EDY:REMOVE LOOSE H #SR30503DO | DOB VIOLATION - ACTIVE |
| Aug 16, 2018 | CONSTRUCTION FTM BLDG.NFP W/MASONRY BRICK WALLS FULL LENGTH CORNICE @3RDFL ROOF IS ROTTED W/HOLES @VARIOUS LOCS&PIECES OF CORNICES FALL OFF.THE ENDS OF THE CORNICES @EXP2&4 ARE ALSO ROTTED&LIKELY TO FALL OFF.REMEDY:OWNER TO HIRE LIC PE TO PREP PLANS&PERM TO REMOVE/RPR CORNICE NO LATER THAN 8/22/18.RPRS START NO #FEU30501DR | DOB VIOLATION - ACTIVE |