6 floors · 21,595 sq ft · built 1930 · class G1 · owner of record: Bf/Rf Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1139 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 2, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS ,FOR VIO39100424P ISSUED ON 11/30/23 .FOR UNPERMITTED STEEL WORK ., FILE A CERTIFICATE OF CORR #39162183R | Dec 11, 2025 DEFAULT | $6,250 |
| Dec 1, 2023 | Construction CLASS - 1 28-323.1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. NOTE: AT THE TIME OF INSPECTION OBSERVED ON AN OCCUPIED PARKING STRUCTURE SPALLING CONCRETE AND EXPOSED RE-BAR FROM BEAM, SLAB AND CEILING AT SE #35675577H | Aug 1, 2024 IN VIOLATION | $0 |
| Nov 30, 2023 | Construction CLASS - 1 WORK WITHOUT PERMIT AT 2ND FLOOR REMOVAL OF CONCRETE ENCASEMENT TO EXPOSE STRUCTURAL STEEL AND INSTALLATION OF NEW STEEL BEAMS ACROSS EXISTING STEEL BEAMS AT SECOND FLOOR AND ALSO CONCRETE WORK AT 3RD &5TH FLOO #39100424P | Mar 20, 2025 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2023 | CONSTRUCTION EMERGENCY WORK ORDER OCCUPIED PARKING STRUCTURE SPALLING CONCRETE& EXPOSED REBAR FROM BEAM &SLAB@SEVERAL LOC.FR.LEVEL 1TO 6 CAUSING AN IMMED.HAZ.TO VEHICULAR AND PED.TRAFFIC,FEQ.IMMED SATEY MEASURES TO BE IMPLEMENTED.REMEDY:RETAIN NYC RDP TO DIRECT&SUPERV.IMMED INSTALLATION OF SAFETY MEASURES UNDER #FA10201MF | DOB VIOLATION - ACTIVE |
| Jun 25, 2007 | ELEVATOR #94441204515 | DOB VIOLATION - ACTIVE |
| Oct 12, 2004 | ELEVATOR #94441110827 | DOB VIOLATION - ACTIVE |
| Jun 4, 2001 | ELEVATOR 1F2112 #9444/138853 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #00382 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 25, 2024 | Parking Structures FTF-PS-INITL Failure to file sub cycle 1A compliance report by 12/31/2023 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 1:26 AM ET. BBL 1005620018.