5 floors · 2 apartments · 9,320 sq ft · built 1871 · class K4 · owner of record: Lf 2024 Retail Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-17 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 14, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVED A WORKER ON A MAKESHIFT PLATFORM BENEATH A SIDEWALK SHED CONTRARY TO BC 3301.6. UPON REQUEST, NO APPROVED DESIGN DRAWINGS WERE PROVIDED FOR THE PLATFORM. CONDITION CREATED #39556595P | May 27, 2027 | $2,500 |
| Jul 14, 2026 | Unknown CLASS - 1 AT THE TIME OF INSPECTION, I OBSERVED ERECTED SUPPORTED SCAFFOLDING CONTRARY TO BC 3314.1. SCAFFOLD WAS MISSING REQUIRED TOE BOARDS AND WORKING PLATFORMS WERE NOT FULLY PLANKED, WITH GAPS EXCEEDING 2 INCHES BET #39556594N | May 27, 2027 | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #03315 | DOB VIOLATION - ACTIVE |
| Oct 9, 2015 | LANDMARK #16-0387 | DOB VIOLATION - ACTIVE |
| Oct 9, 2015 | LANDMARK #16-0390 | DOB VIOLATION - ACTIVE |
| Oct 9, 2015 | LANDMARK #16-0391 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 8) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 30, 2014 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CARD BOARD BOXES AND OTHER HOUSE HOLD ITEMS AT PUBLIC HALL, 4th STORY | Aug 4, 2014 |
| Jun 30, 2014 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT TIME OF INSP. AT PUBLIC HALL, 1st STORY | Oct 3, 2014 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 19, 2026 | DOB Safety | AEUHAZ: | Closed |
| Jul 14, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION, I OBSERVED A WORKER ON A MAKESHIFT PLATFORM BENEATH A SIDEWALK SHED CONTRARY TO BC 3301.6. UPON REQUEST, NO APPROVED DESIGN DRAWINGS WERE PROVIDED FOR THE PLATFORM. CONDITION CREATED | Closed |
| Jul 14, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION, I OBSERVED ERECTED SUPPORTED SCAFFOLDING CONTRARY TO BC 3314.1. SCAFFOLD WAS MISSING REQUIRED TOE BOARDS AND WORKING PLATFORMS WERE NOT FULLY PLANKED, WITH GAPS EXCEEDING 2 INCHES BET | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 2:08 PM ET. BBL 1013760021.