Brooklyn · Block 1883 · Lot 7 · 11205

67 Taaffe Place

12 floors · 55,815 sq ft · built 2025 · class O6 · owner of record: 67 Taaffe Llc

0open violations
$24,755ECB/OATH penalties owed
0HPD class C (immediately hazardous)
191dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 55,815 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 191 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 191 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 801 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 853 days
Filing window not open yet
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1883). Agency page

Dec 31, 2033
in 2627 days
Next due 2033

Open violations

ECB / OATH (9) · $24,755 owed
IssuedViolationHearingBalance
Dec 21, 2025Construction CLASS - 1
NOTE: AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, ONGOING FACADE OPERATIONS AND SUPPORTED SCAFFOLD DISMANTLING WERE OBSERVED.UPON REQUESTING THE SITE SAFETY COORDINATOR, A WORKER STATED THAT THE C
#39548319Z
Dec 28, 2026
DEFAULT
$10,030
Dec 21, 2025Unknown CLASS - 2
NOTE: AT TIME OF INSPECTION, I OBSERVED A SUPPORTED PIPE SCAFFOLD IN PLACE, AT EXPOSURES# 4 THE DEBRIS NETTING WAS NOT SECURELY ATTACHED TO THE SCAFFOLD AT MULTIPLE LOCATIONS AS REQUIRED BY CODE (3314.8.2). THI
#39548320X
Mar 22, 2027
$2,500
Dec 21, 2025Unknown CLASS - 2
PROHIBITED SIGNS POSTED CONTRARY TO CODE 3301.9.7 NOTE: AT TIME OF INSPECTION, I OBSERVED A SIDEWALK IN PLACE WITH PROHIBITED SIGNS POSTED ON THE PARAPET PANELS AT EXPOSURE# 1, REMOVE ALL ILLEGAL SIGNAGE.
#39548321H
Mar 22, 2027
$2,500
Sep 27, 2025Unknown CLASS - 2
BC3303.3 WATCHPERSON 12 STORY NEW BUILDING, BUILDING APPROXIMATELY 6276 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WATCHP
#39545410X
Jan 19, 2027
$2,500
Sep 27, 2025Construction CLASS - 2
OBSERVED JERSEY BARRIERS OCCUPYING ROADWAY AT EXP#1 NOT AS PER MANUFACTURES SPECIFICATION. JERSEY BARRIERS SEVERAL DAMAGED (CRACKED) ALSO BARRIERS NOT FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLO
#39545411H
Jan 19, 2027
$1,250
Aug 9, 2025Unknown CLASS - 2
ATOI OF AN 12-STORY NB APPROX. 6453 SQ FT. SITE WAS CLOSED AND THERE WAS NO ONGOING CONSTRUCTION ACTIVITY. UPON SHOUTING AROUND THE PERIMETER AND BANGING ON FENCE/DOOR MULTIPLE TIMES TO ALERT WATCHPERSON AND TO
#39543496R
Jan 7, 2027
$2,500
Aug 9, 2025Construction CLASS - 2
NOTE: AT TIME OF INSPECTION, I OBSERVED MULTIPLE BARRIERS IN PLACE WITH CRACKS AT THE BOTTOM PREVENTING THEM FROM BEING FILL AND THE OTHERS NOT FILL WITH WATER/SAND WHICH POSES A SIGNIFICANT HAZARD BY ALLOWING
#39543497Z
Jan 7, 2027
$1,250
Jul 31, 2025Construction CLASS - 2
AT THE TIME OF MY INSPECTION OF A 12 STORY NEW BUILDING TOP OFF, I OBSERVED STAND PIPE INSTALLED FROM THE BASEMENT TO THE BULKHEAD, UPON REQUEST FOR HYDROSTATIC TEST ABOVE 75 FEET NONE WAS PRESENTED OR AT JOBSI
#39543106M
Jun 25, 2026
IN VIOLATION
$625
Jul 31, 2025Unknown CLASS - 1
AT THE TIME OF MY INSPECTION OF A 12 STORY NEW BUILDING TOP OFF, I OBSERVED STAND PIPE INSTALLED FROM THE BASEMENT TO THE BULKHEAD, UPON REQUEST FOR THE ELECTRICAL PERMIT FOR THE AIR PRESSURE ALARM SYSTEM NONE
#39543103R
Jun 25, 2026
IN VIOLATION
$1,600
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 3:58 PM ET. BBL 3018830007.