Bronx · Block 3074 · Lot 47 · 10458

660 East 187 Street

5 floors · 26 apartments · 18,640 sq ft · built 1906 · class C7 · owner of record: Cht Trust

27open violations
$5,000ECB/OATH penalties owed
14HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 46 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 46 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 62 days
Annual

Open violations

ECB / OATH (2) · $5,000 owed
IssuedViolationHearingBalance
Jul 14, 2026Construction CLASS - 1
FAILURE TO MAINTAIN PEDESTRIAN PROTECTION. AT THE TIME OF INSPECTION, YODOCK BARRIERS WERE NOT INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS. REQUIRED SAND BALLAST/WATER WAS MISSING, AND THE ATTACHED CHAIN-LI
#39196114Z
Apr 15, 2027
$2,500
Jun 1, 2026Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. DOB-EWO #350627C042226FEU20601TCJ DATED 4/22/26 REQUIRED OWNER TO DEMOLISH REMAINDER OF PARAPET AFTER PARTIAL COLLAPSE REMOVE ALL DEBRIS AND TO INSTAL
#35718677M
Mar 15, 2027
PENDING
$2,500
DOB (3)
IssuedViolationStatus
Apr 27, 2026CONSTRUCTION
FTC W/THE COMMISSIONER'S ORDER CONTROL#350627 ISSUED ON 04/22/26 FOR EMERGENCY WORK TO MAKE CONDITIONS SAFE FOR BLDG THAT WAS SEVERELY DAMAGED BY FIRE ON 04/21/26.TO DATE THE OWNET HAS FAILED TO ENGAGE PE & CONTR & SUBMIT THE MEANS/METHODS BY 04/23/26. IMMED COMPLY WITH THE COMMISSIONER'S ORDER CONT
#FEU20601XC
DOB VIOLATION - ACTIVE
Apr 22, 2026CONSTRUCTION
EMERGENCY WORK ORDER.SEVERELY DMGD BY FIRE ON 4/21/26.ROOF PRTLLY CLLPSD PARAPETS OF ALL EXT WALLS PRTLLY CLLPSD.LOOSE CORNICE@FRONT WALL&LOSE BRCKS@ALL EXT WALLS IN DANGR OF FALLNG.SEVERE WATR DMG IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER-CONTROL #350627
#FEU20601XC
DOB VIOLATION - ACTIVE
Apr 21, 2026CONSTRUCTION
STRUCTURE RENDERED NON-COMPLIANT. DAMAGES OBSERVED TO HAVE BEEN SUSTAINED DO TO FIRE. THE ROOF HAS PARTIALLY COLLAPSED WITH IN THE STRUCTURE AS WELL AS A PARTIAL COLLAPSE OF THE PARAPET WALL AT EXPOSURE#1. THERE IS THE POTENTIAL FOR FURTHER COLLAPSE. VACATE ENTIRE FORTHWITH.
#26-01108
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 16, 2026Structurally Compromised Buildings FTF-SC-INITL
Report due for structurally compromised property
Active
HPD (22) · C 14 · B 4 · A 3
IssuedClassViolationCorrect by
Apr 23, 2026I§ 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER, UNTIL (1) AN APPLICATION AND PLAN FOR THE WORK REQUIRED BY THIS ARTICLE HAVE BEEN FILED WITH AND APPROVED BY THE DEPARTMENT OF BUILDINGS, WHERE REQUIRED, (2) SUCH WORK HAS —
Aug 31, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ASPHALT AND WOOD DECKING AT ROOFSep 6, 2026
Aug 31, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR JOINTS AT ALL PARAPET WALLSSep 6, 2026
Aug 31, 2026C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE THROUGHOUT BUILDING AFFECTING ALL APARTMENTSSep 6, 2026
Aug 31, 2026C§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT ALL APARTMENT THROUGHOUT BUILDINGSep 6, 2026
Aug 31, 2026C§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT ALL APARTMENTS THROUGHOUT BUILDING.Sep 6, 2026
Aug 31, 2026C§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES THROUGHOUT ALL PUBLICC HALLS AND APARTMENTSSep 6, 2026
Apr 29, 2026A§ 27-2027 ADM CODE REGRADE WITH THE PROPER SLOPE TO EXISTING DRAIN THE SURFACE AT REAR YARDAug 2, 2026
Apr 29, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK WALL AT WEST EXTERIOR WALL AT REAR YARDMay 5, 2026
Apr 23, 2026C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DECKING AND ASPHALT MATERIAL AT ROOFApr 29, 2026
Mar 16, 2026CApt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTApr 11, 2026
Mar 16, 2026CApt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WESTApr 11, 2026
Dec 20, 2024CApt 13 · § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.Dec 24, 2024
Dec 20, 2024CApt 13 · § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.Dec 24, 2024
Dec 26, 2023CApt 4 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 25 SQ FT AT NORTH WALL, 25 SQ FT AT EAST WALL, 25 SQ FT AT WEST WALL, 25 SQ FT AT SOUTH WALL AND 25 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJan 21, 2024
Feb 23, 2023A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES ALL BALCONIES AND ALL COMPONENTS AT EAST STACK AT BUILDING FRONT AT FIRE ESCAPEMay 29, 2023
Feb 23, 2023A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES ALL BALCONIES AND ALL COMPONENTS AT WEST STACK AT BUILDING FRONT AT FIRE ESCAPEMay 29, 2023
Sep 13, 2021B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE METAL CORNICE ON TOP OF 4TH FLOOR AT SOUTHEAST SIDE OF BUILDING AT CORNICEOct 18, 2021
Mar 8, 2021CApt 18 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 18, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHApr 3, 2021
Nov 6, 2019BApt 18 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 18, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHDec 11, 2019
Nov 6, 2019BApt 18 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 18, 4th STORY, 1st APARTMENT FROM NORTH AT EASTDec 11, 2019
Nov 6, 2019BApt 12 · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT THE DOOR LEADING TO ROOM WITH FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 12, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTDec 11, 2019

Issued in the last 120 days

DateSourceWhatNow
Sep 16, 2026DOB SafetyStructurally Compromised Buildings: Report due for structurally compromised propertyOpen
Aug 31, 2026HPD C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ASPHALT AND WOOD DECKING AT ROOFOpen
Aug 31, 2026HPD C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR JOINTS AT ALL PARAPET WALLSOpen
Aug 31, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE THROUGHOUT BUILDING AFFECTING ALL APARTMENTSOpen
Aug 31, 2026HPD C§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT ALL APARTMENT THROUGHOUT BUILDINGOpen
Aug 31, 2026HPD C§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT ALL APARTMENTS THROUGHOUT BUILDING.Open
Aug 31, 2026HPD C§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES THROUGHOUT ALL PUBLICC HALLS AND APARTMENTSOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 12:46 AM ET. BBL 2030740047.