Queens · Block 3152 · Lot 41 · 11374

66-20 Thornton Place

4 floors · 25,744 sq ft · built 1955 · class W2 · owner of record: United Talmudical Seminary

20open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
59dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 59 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 59 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 25,744 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 180 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 180 days
Annual filing
Annual boiler inspection (4 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-23 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7)
IssuedViolationHearingBalance
May 2, 2016Construction CLASS - 1
WORK W/O A PERMIT. ON THE ABOVE DATE AT 11:15PM I OBSERVED GAS PIPING REMOVED AS PER VIO#35141529R I ALSO OBSEVED NEW PIPING FITTINGS INSTALLED ON THE SAME LINE.NO PERMITS/INSPECTION OR TESTING ON FILE W/DOB AT
#35180985M
Dec 6, 2016
IN VIOLATION
$0
May 2, 2016Plumbing CLASS - 1
GAS BEING SUPPLIED TO BUILDING W/OCT INSPECTION AND CERTIFICATION BY DOB. ON THE ABOVE DATE AT 1:15PM I OBSERVED THE REMOVAL OF GAS PIPING AND THE INSTALLATION OF NEW GAS PIPING IN THE BOILER ROOM IN THE CELLA
#35180986Y
Dec 6, 2016
IN VIOLATION
$0
Nov 16, 2015Plumbing CLASS - 2
PIPING AND/OR EQUIPMENT INSTALLED IMPROPERLY:INCREASE I SIZE OF GAS PIPE IN BOILER ROOM.INSPECTION TIEM 8:30.ON 11-16-15,I OBSERVED IN BOILER ROOM IN CELLAR OF AVBOVE CITED PROPERTY 1 1/2 GAS PIPING INCREASED T
#35141528P
Jan 19, 2016
IN VIOLATION
$0
Nov 16, 2015Construction CLASS - 2
ALTERED/CHANGED BUILDING IS OCCUPIED WITHOUT A VALID CERTIFICATE OF O CCUPANCY AS PER 28-118.3.1.NOTED:PREMISES FILED JOB #401016477 ALT-1 ON 9/01/1999,TO ERECT A NEW (2) ADDITIONAL FLOOR (AWG) AND CHANGE THE U
#35136370H
Jan 19, 2016
STIPULATION/IN-VIO
$0
Nov 16, 2015Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER: FAILURE TO PROVIDE A STORM DRAINAGE SYSTEM. INSPECTION TIME 8:30AM ON 11-16-15,I OBSERVED ON THE ABOVE CITED PROPERTY STORM GUTTERS THAT DUMPED WATER ONTO
#35141527N
Jan 19, 2016
STIPULATION/IN-VIO
$0
Nov 25, 2013Construction CLASS - 1
ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCYAS PER 28-118.3.1-28-118.3.2 NOTED: UNDER ALTERATION PERMIT #40101647701-AL WORK HAS BEEN COMPLETED AND BUILDING IS NOW OCCUPIED AT CELLAR,
#35080675Z
Jan 14, 2014
IN VIOLATION
$0
Apr 25, 2012Unknown CLASS - 3
ALTERED/CHANGED BLDG OCCUPIED W/O A VALID C/O AS PER 28-118.3.1-28.118.3.2 NOTED BLDG UNDER ALT JOB #401009680 & TEMP C/O #401016477 EXPIRED6.1.01 OBSERVED 3 FLR ARRANGED AS DORMITORY SLEEPING AREA. REMEDY:
#34951595N
Jan 16, 2013
IN VIOLATION
$0
DOB (6)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06607
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06608
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06609
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06610
DOB VIOLATION - ACTIVE
Nov 16, 2016FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00585
DOB VIOLATION - ACTIVE
Nov 16, 2016FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00584
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 16, 2016AEUHAZ FTC-AEU-HAZ
Active
Nov 16, 2016AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 2, 2026, 8:06 PM ET. BBL 4031520041.

Look up another building