5 floors · 57,900 sq ft · built 1921 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 57,900 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1165 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2683). Agency page | Dec 31, 2033 in 2626 days | Next due 2033 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-16 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 13, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, WORKER INJURY INVESTIGATION CONDUCTED AT 5-STORY PS 062 BUILDING. WORKER WAS PERFORMING DRILLING OPERATION FOR WINDOW GUARD INSTALLATION USING A BOSCH DRILL. OBSERVED DRILL MISSING A REQU #39556521M | Apr 12, 2027 | $2,500 |
| Jul 13, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, SCAFFOLD AT EXPOSURE 3, ROOF LEVEL OF THE 2-STORY AUDITORIUM SECTION OF PS 062, OBSERVED NOT PROPERLY MAINTAINED. MISSING GUARDRAILS, TOE-BOARDS ON BICYCLE BRACKETS, AND GAPS IN SCAFFOLD #39556535N | Apr 12, 2027 | $5,000 |
| May 27, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OF A 5-SORY BUILDING, ACTIVE SITE WHERE WORK BEING 3:30PM TO 12:00AM. DATE 05/22/2026, WHERE A WORKER GOT HURT DURING A/C INSTALLATION APPROX. 9:45PM. UPON RESEARCHING THE DEPARTMENT O #39554665M | Jan 25, 2027 | $2,500 |
| May 27, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, IT WAS REPORTED THAT ON 05/22/2026, WORKER MARCIO MOURA WAS INSTALLING AN A/C SUPPORT BRACKET WHEN THE BRACKET ASSEMBLY FAILED AND STRUCK THE WORKER IN THE HEAD, CAUSING INJURY. THE INJUR #39554661P | Jan 25, 2027 | $5,000 |
| Mar 10, 2022 | Construction CLASS - 1 UNLAWFUL ACTS FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS.RECORDS INDICATE NO APP MADE TO CORRECT OR CERTIFY ECB #35359888K & ECB # 35644627P.REMEDY:COMPLY WITH COMMISSIONER'S ORDERS. #35644997M | Jun 17, 2022 POP/IN-VIO | $0 |
| Jan 16, 2022 | Construction CLASS - 1 UNLAWFUL ACTS FAILURE TO COMPLY WITH COMMISSIONERS ORDERS.RECORDS INDICATE NO APP WAS MADE TO CORRECT OR CERTIFY ECB#'S 35634469J & 35359888K.REM:COMPLY WITH COMMISSIONERS ORDERS. #35644627P | Apr 29, 2022 POP/IN-VIO | $0 |
| Dec 1, 2021 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH ORDER OF COMMISSIONER.ELECTRICAL WORK W/O PERMIT. OUTDOOR CONSTRUCTION TRAILERS SUBFEEDERS SUB PANELS BRANCH CIRCUIT WIRING RECEPTACLES OUTLETS SWITCHES LIGHTS.PLEASE NOT Y1 #35634469J | Mar 4, 2022 POP/IN-VIO | $0 |
| Sep 21, 2021 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS ECB#35359888K AND ECB#35359889M.ELECTRICAL WORK WITHOUT A PERMIT OUTDOOR CONSTRUCTION TRAILER SWO FEEDER #35584008Y | Dec 3, 2021 DEFAULT | $6,250 |
| Aug 5, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/ VIOLATION 35359887Z ISSUED ON 05/13/19 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. UNAPPROVED UNSAFE UNSU #35426889J | Sep 20, 2019 DEFAULT | $6,250 |
| May 13, 2019 | Unknown CLASS - 1 UNAPPROVED, UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES ON WORING IN USE. BACKYARD SCHOOL; THE TEMPORARY WIRING ARE NOT PROPERLY SUPPORTED. FLEXIBLE CORDS USED OUTDOOR, TEM #35359887Z | Aug 2, 2019 DEFAULT | $4,000 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #05945 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #05946 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #05944 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 13, 2026 | ECB | Construction: AT TIME OF INSPECTION, WORKER INJURY INVESTIGATION CONDUCTED AT 5-STORY PS 062 BUILDING. WORKER WAS PERFORMING DRILLING OPERATION FOR WINDOW GUARD INSTALLATION USING A BOSCH DRILL. OBSERVED DRILL MISSING A REQU | Closed |
| Jul 13, 2026 | ECB | Construction: AT TIME OF INSPECTION, SCAFFOLD AT EXPOSURE 3, ROOF LEVEL OF THE 2-STORY AUDITORIUM SECTION OF PS 062, OBSERVED NOT PROPERLY MAINTAINED. MISSING GUARDRAILS, TOE-BOARDS ON BICYCLE BRACKETS, AND GAPS IN SCAFFOLD | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 5:13 AM ET. BBL 2026830065.