| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 795 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-08 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 21, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #35719018N, FILE A CERTIFICATE OF CORRECTION #39204885Y | Dec 2, 2026 PENDING | $1,250 |
| Sep 21, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #35718815L, FILE A CERTIFICATE OF CORRECTION #39204884M | Dec 2, 2026 PENDING | $1,250 |
| Feb 13, 2026 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER NO COMPLIANCE ON FILE FOR ANNUAL PARAPET OBSERVATION REPORT.VIO#101325PI30104HZ CONTROL#348359.REM:COMPLY WITH THE COMMISSIONER'S ORDER. #35718815L | Mar 1, 2027 PENDING | $2,500 |
| Jan 7, 2026 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER #193125PI30103HZ AND CONTROL #348358 DATED 10/31/2025. NO COMPLIANCE ON FILE FOR CORRECTIVE ACTION PLAN. REMEDY: COMPLY WITH THE COMMISSIONER'S ORDER. #35719018N | Feb 16, 2027 DEFAULT | $6,280 |
| Sep 11, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.I OBSERVED AT VARIOUS LOCATIONS-MISSING MORTAR AROUND ORNAMONTAL STONE WORK AT EXPOSURE ONE DISLODGE BRICKS AT CORNER EDGE ON BOTH SIDE OF THE BLDG AT ROOF #35719032J | Jul 28, 2026 IN VIOLATION | $1,250 |
| May 6, 2025 | Unknown CLASS - 1 FAILURE TO COMPLY WITH TPP. ATOI OBSERVED TPP UNDER JOB#B01184696 STATES "DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM, AND TO BE CONFINED TO IMMEDIATE CONSTRUCTION AREA". OBSERVED EXCESSIVE LEAD DUST IN COMMO #39150073H | Nov 9, 2026 | $10,000 |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | CONSTRUCTION FTC W/COMMISSIONER'S ORDER CONTROL#348286 VIO#091125PI30101HZ DATED 09/11/25 REQUIRING OWNER TO PROVIDE THE ANNUAL PARAPET OBSERVATION REPOT AS REQ'D FOR 2024.AS OF 10/31/25 THE ANNUAL PARAPET OBSERVATION REPORT WAS NOT REC'D BY 09/25/25. IMMED COMPLY W/COMMISSIONER'S ORDER CONTROL#348286 VIO#091125 #PI30104HZ | DOB VIOLATION - ACTIVE |
| Oct 31, 2025 | CONSTRUCTION FTC W/COMMISSIONER'S ORDER CONTROL#348287 VIO#091125PI30102HZ DATED 09/11/25 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY/ 09/23/25. AS OF 10/31/25 THE CAP DOCUMENTS WAS NOT REC'D. IMMED COMPLY W/COMMISSIONER'S ORDER UNDER 348287 VIO#091125PI30102HZ TO PROVIDE A CORRECTIVE ACTION PLAN,SUBM #PI30103HZ | DOB VIOLATION - ACTIVE |
| Sep 11, 2025 | CONSTRUCTION FTM BLDG IN CODE COMPLIANT MANNER-@ ROOFTOP LEVEL DISLODGE BRICKS & MISSING MORTAR @ BOTH CORNER EDGE OF THE BLDG. @ EXP2-3-4 MINOR SPALLING @ TOP COATING & BRICKS ALONG THE PARAPET WALLS. SUBMIT ANNUAL PARAPET OBSERVATION REPORT FOR YEAR 2024 ANT TO BE REC'D BY DOB NO LATER THAN SEPTEMBER 25, 2025 #PI30101HZ | DOB VIOLATION - ACTIVE |
| Sep 11, 2025 | CONSTRUCTION CORRECTIVE ACTION PLAN REQ'D-OBSVD @ FRONT FACADE ORNAMENTAL STOME WORK MISSING MORAR IN BTWN CRACKED STONE WORK DISLODGMENT OF STONE WORK @ 4TH&5TH FLRS REAR PARAPET WALL IN DISREPAIR,DISLODGEMENT BRACING AROND CHIMNERY. OWNER TO IMMED RETAIN REG DESING PROF TO EVAL THE ENTIRE BLDG & TO SUBMIT A CO #PI30102HZ | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 5, 2025 | C | Apt 3E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30SQ FEET AT ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 1, 2025 |
| Jun 11, 2024 | B | Apt 52 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1 SQ.FT AT CEILING IN THE KITCHEN LOCATED AT APT 52, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16662999 ISSUED 09-FEB-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b) | Jul 16, 2024 |
| Feb 12, 2024 | C | Apt 52 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE REPLACE EXISTING DOOR WITH FIRE RESISTANT SELF CLOSING DOOR WITH CHAIN GUARD, PEEPHOLE AND HEAVY DUTY LOCK AT ENTRANCE LOCATED AT BSMT-APT 52, 1st BSMT-APT FROM EAST AT SOUTH | Feb 18, 2024 |
| Jul 10, 2023 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CORNICE AT BUILDING FRONT AT LEFT SIDE | Aug 14, 2023 |
| Jun 9, 2023 | C | Apt 3F · § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES. | Jun 13, 2023 |
| Jun 9, 2023 | C | Apt 3F · § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS. | Jun 13, 2023 |
| Oct 12, 2022 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ALUMINUM ORNAMENTAL CORNICE, EXTERIOR FACADE AT ROOF, BUILDING FRONT | Nov 16, 2022 |
| Jul 20, 2022 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR JOINTS AT PARAPET WALL THROUGHOUT ENTIRE ROOM | Jul 26, 2022 |
| Jan 26, 2022 | B | Apt 2D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( APPROXIMATELY 3SQFT) CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 14588281 ISSUED 24-SEP-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27- | Mar 2, 2022 |
| Sep 29, 2021 | B | Apt 2D · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WASH BASIN, AT SOUTH WALL, IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 3, 2021 |
| Sep 29, 2021 | B | Apt 2D · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING KNOBS AT, SHUT-OFF VALVES, WASH BASIN, SOUTH WALL, IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 3, 2021 |
| Feb 4, 2021 | B | Apt 3E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SASHES (APPROX. 5 SQ. FT.) AT SOUTH WINDOW IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 13843552 ISSUED 01-OCT-20 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIV | Mar 11, 2021 |
| Oct 8, 2020 | A | Apt 5D · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD WAINSCOTT ON ALL WALLS IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 11, 2021 |
| Oct 5, 2020 | B | Apt 2D · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDLE FOR RADIATOR SHUT OFF VALVE IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 9, 2020 |
| Oct 5, 2020 | B | Apt 2D · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE MISSING WASH BASIN IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 9, 2020 |
| Oct 5, 2020 | B | Apt 2D · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDLE FOR RADIATOR SHUT OFF VALVE IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 9, 2020 |
| Oct 5, 2020 | B | Apt 2D · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDLE FOR RADIATOR SHUT OFF VALVE IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 9, 2020 |
| Mar 3, 2020 | B | Apt 3E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE SASHES OF THE WINDOW IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 13408149 ISSUED 31-OCT-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a | Apr 7, 2020 |
| Jul 29, 2019 | C | Apt 3E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 19, 2019 |
| Jul 29, 2019 | B | Apt 3E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL, APPROXIMATELY 10 SQ. FEET IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 2, 2019 |
| Mar 11, 2019 | C | Apt 3E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 1, 2019 |
| Mar 11, 2019 | B | Apt 3E · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUCHEON PLATE ON RISER AT EAST WALL IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 15, 2019 |
| Mar 11, 2019 | B | Apt 3E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL (APPROX. 15SQ.FT.) IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 15, 2019 |
| Apr 19, 2018 | B | Apt 2D · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROX 2 SQ FT AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 24, 2018 |
| Jan 29, 2018 | B | Apt 2D · § 27-2005 ADM CODE PROVIDE WASH BASIN IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 5, 2018 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 21, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #35719018N, FILE A CERTIFICATE OF CORRECTION | Open |
| Sep 21, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #35718815L, FILE A CERTIFICATE OF CORRECTION | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)