Manhattan · Block 1075 · Lot 29 · 10036

653 10 Avenue

8 floors · 20 apartments · 25,617 sq ft · built 2012 · class D6 · owner of record: 653 Tenth Avenue Llc

11open violations
$12,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 67 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $183,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 119 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 25,617 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-25 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7) · $12,000 owed
IssuedViolationHearingBalance
Sep 5, 2024Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED SIDEWALK SIDE IN PLACE AT EXPO#1-4 WITH NO LIGHT UNDER THE SIDEWALK SHED CREATING UNSAFE CONDITION FOR PEDESTRIAN BC3307.6.4.8 LIGHT ..
#39532079M
Nov 14, 2024
IN VIOLATION
$2,400
May 13, 2024Construction CLASS - 2
OBSERVED SIDEWALK SHED IN PLACE AT EXP#1&2 AND SIDEWALK SHED WITH NO UNDERSIDE LIGHTS, NOT ILLUMINATED, AND WALKING WAS DARK. THIS CONDITION POSES A TRIPPING HAZARD AND COULD CAUSE IN SERIOUS INJURY. RECURRING
#39528517L
Jul 18, 2024
IN VIOLATION
$2,400
Apr 26, 2024Construction CLASS - 2
AT 5:53AM OBSERVED SWS THAT WAS NOT ILLUMINATED AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF SLIPS AND TRIPS DUE TO INADEQUATE LIGHTING IN DARK CONDITIONS AND NO PREVENTIVE MEA
#39528001K
Jul 11, 2024
IN VIOLATION
$2,400
Sep 1, 2023Construction CLASS - 2
FAILURE TO MAINTAIN SIDEWALK SHED AT EXPOSURE ONE. CROSS BRACE WAS DISPLACED, DAMAGE, BEND CREATING HAZARDOUS OF COMPROMISING STRENGTH AND OBSTRUCT PEDESTRIAN WALKWAY WHICH MAY CAUSE INJURIES. RESPONDENT DIDN'T
#39521284H
Mar 22, 2024
IN VIOLATION
$2,400
Mar 31, 2022Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED IN PLACE W/LIGHTS NOT IN OPERATING CONDITION. REMEDY: COMPLY W/CODE-PROVIDE LIGHTING DUSK-DAWN.
#35646031N
Oct 13, 2022
IN VIOLATION
$2,400
Jul 21, 2021Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE ATTHE TIME OF INSPECTION OBSERVED DEFECTIVE FACADE AT EXP1 AND 4 DEFECTIVE STONE WORK,VERTICAL CRACKS AT PARAPET WALL.EXP2 WEST ELEVATION DAMA
#35488917L
Feb 17, 2022
IN VIOLATION
$0
Jun 8, 2021Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE/WALLS AND APPURTENANCES.NOTE:AT TIME OF INSPECTION OBSERVED AT EXP #1 SOUTH ELEVATION AND EXP #4 EAST ELEVATION:VERTICAL CRACKS ON PARAPET WALLS.DAMAGED MORTAR JOINT
#35577614Z
Mar 24, 2022
IN VIOLATION
$0
DOB (3)
IssuedViolationStatus
Jan 24, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#909584
DOB VIOLATION - ACTIVE
Jul 21, 2021CONSTRUCTION
FTM EXTERIOR BUILDING FACADE AND APPURTENANCES. AT TIME OF INSP OBSERVED DEFECTIVE FACADE AT EXP 1 AND 4, VERTICLE CRACKS AT PARAPET WALL AT EXP 2, DAMAGED METAL PANELS. REMEDY: MAINTAIN EXTERIOR BLDG FACADE, TAKE SAFETY MEASURES, REPAIR DAMAGED FACADE AND PROVIDE RA/PE REPORT REGARDING FACADE CONDI
#LLFA01LJ
DOB VIOLATION - ACTIVE
Jun 22, 2000ELEVATOR
1F3679
#9444/124227
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Jan 24, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 2:35 PM ET. BBL 1010750029.