Bronx · Block 3558 · Lot 13 · 10473

652 Soundview Avenue

4 floors · 7 apartments · 7,500 sq ft · built 1929 · class C7 · owner of record: 652-308 Gv Llc

13open violations
$0ECB/OATH penalties owed
6HPD class C (immediately hazardous)
62dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 62 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 62 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 78 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 306 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-18 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Apr 29, 2024Boilers CLASS - 2
FOUND ON H.B SMITH MODEL 19A4 BTU 530,000 SECTIONS LEAKING ON BOILER, NEED TO REMOVE ALL OIL BUCKETS AND CLEAN BOILER ,CLEAN CHIMNEY BASE, NEED LOCK ASSEMBLY FOR BOILER DOOR
#39112848R
Jul 5, 2024
STIPULATION/IN-VIO
$0
DOB (1)
IssuedViolationStatus
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#05566
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
HPD (10) · C 6 · B 4 · A 0
IssuedClassViolationCorrect by
Sep 3, 2024C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXCESSIVE WIRING AROUND DROP LADDER AT BUILDING FRONTSep 9, 2024
Jun 24, 2024B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GARBAGE IMPEDING DROP LADDER FROM FULLY EXTENDING TO GROUND AT WEST EXTERIOR WALL FIRE ESCAPE( BUILDING FRONY) AT FIRE ESCAPEJul 29, 2024
Jun 24, 2024CApt 4B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 20, 2024
Jun 24, 2024B§ 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON EAST ROOF DOOR THAT ALLOWS RE-ENTRY FROM ROOF TO PUBLIC HALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORYJul 29, 2024
Jun 24, 2024CApt 4B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER AND RETURN VOICE INTERCOM SYSTEM FROM BUILDING ENTRANCE DOOR UP TO PANEL AT SOUTH WALL IN THE FOYER LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 30, 2024
Jun 24, 2024B§ 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON WEST ROOF DOOR THAT ALLOWS RE-ENTRY FROM ROOF TO PUBLIC HALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 4th STORYJul 29, 2024
Jun 17, 2024CApt 4B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EASTJul 13, 2024
Apr 29, 2024B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GARBAGE CANS OBSTRUCTING MOTION TO DROP LADDER AT FIRE ESCAPE AT BUILDING FRONT ENTRANCE AT PUBLIC HALLJun 3, 2024
Dec 21, 2022CApt 2B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOJan 14, 2023
Jun 16, 2022CApt 4B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 10 SQ. FT. AT NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14789604 ISSUED 19-JAN-22 HAS BEEN UPGRADED TO CLASS C PER ADMINIJul 12, 2022

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 6:42 PM ET. BBL 2035580013.

Look up another building