Manhattan · Block 1602 · Lot 7501 · 10128

65 East 96 Street

16 floors · 60 apartments · 97,000 sq ft · built 1924 · class RM · owner of record: The Gatsby Condominium Association

18open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 97,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 412 days
Next cycle year 2027
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 830 days
Filing window not open yet
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1602). Agency page

Dec 31, 2032
in 2239 days
Next due 2032
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-30 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Jul 20, 2022Construction CLASS - 2
16 AC WINDOW UNITS INSTALLED AT VARIOUS LOCATIONS WITHOUT SAFTEY BRACKETS, REPAIR AND/OR REPLACE
#39066348X
Nov 10, 2022
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (17) · C 3 · B 9 · A 5
IssuedClassViolationCorrect by
Sep 18, 2026C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICK DOWN STOPPER INSTALLED AT BUILDING ENTRANCE DOOROct 2, 2026
Sep 18, 2026C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICK DOWN STOPPER INSTALLED AT VESTIBULE DOOR , 1st STORYOct 2, 2026
Oct 27, 2010BApt 14D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 4th BATHROOM FROM EAST AT NORTH LOCATED AT APT 14D, 14th STORY, 2nd APARTMENT FROM SOUTH AT WESTDec 1, 2010
Oct 27, 2010BApt 14D · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB IN THE 3rd BATHROOM FROM EAST AT SOUTH LOCATED AT APT 14D, 14th STORY, 2nd APARTMENT FROM SOUTH AT WESTDec 1, 2010
Oct 12, 2010BApt 14D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM FROM NORTH AT EAST LOCATED AT APT 14D, 14th STORY, 2nd APARTMENT FROM SOUTH AT WESTNov 16, 2010
Oct 12, 2010BApt 14D · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 14D, 14th STORY, 2nd APARTMENT FROM SOUTH AT WESTNov 16, 2010
Oct 12, 2010BApt 14D · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 14D, 14th STORYNov 16, 2010
Jan 4, 2005CApt 16C · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 16C, 16th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 30, 2005
Oct 20, 2004AApt 16C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM WEST AT NORTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL, NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 16C, 16th STORY, 1st APARTMENT FROM WEST AT NORTHJan 28, 2005
Oct 20, 2004BApt 16C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 16C, 16th STORY, 1st APARTMENT FROM WEST AT NORTHNov 29, 2004
Oct 20, 2004BApt 16C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 16C, 16th STORY, 1st APARTMENT FROM WEST AT NORTHNov 29, 2004
Oct 20, 2004AApt 16C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM WEST AT NORTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL, NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 16C, 16th STORY, 1stJan 28, 2005
Oct 20, 2004AApt 16C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM WEST AT NORTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL, CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 16C, 16th STORY, 1st APARTMENT FROM WEST AT NORTHJan 28, 2005
Oct 20, 2004BApt 16C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 16C, 16th STORY, 1st APARTMENT FROM WEST AT NORTHNov 29, 2004
May 27, 2003BApt 4D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL AND CEILING AT CLOSET IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM SOUTH AT WESTJul 6, 2003
Jun 26, 1990A§ 27-2027 ADM CODE PROVIDE PROPERLY TRAPPED, SEWER CONNECTED, RAIN LEADER SO AS TO PROVIDE PROPER DRAINAGE AND FILE AN APPLICATION FOR APPROVAL BEFORE DOING THE WORK ROOF TO WEST TERRACE 17 STY SOUTHEAST APT 17F.Oct 12, 1990
Mar 27, 1990AApt 17R · § 27-2005 ADM CODE REFIT FIRE DOORS TO ROOF 2 ROOM FROM NORTH & SOUTH ROOMS 17 STY EAST PENTHOUSE APT 17R. , SECTION '' ''Jul 13, 1990

Issued in the last 120 days

DateSourceWhatNow
Sep 18, 2026HPD C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICK DOWN STOPPER INSTALLED AT BUILDING ENTRANCE DOOROpen
Sep 18, 2026HPD C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICK DOWN STOPPER INSTALLED AT VESTIBULE DOOR , 1st STORYOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 1:21 PM ET. BBL 1016027501.

Look up another building