Manhattan · Block 2138 · Lot 187 · 10032

647 West 169 Street

6 floors · 21 apartments · 14,224 sq ft · built 1925 · class C1 · owner of record: 647 West 169th Llc

25open violations
$0ECB/OATH penalties owed
6HPD class C (immediately hazardous)
44dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 409 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-23 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (2)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#18464
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#40141
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (21) · C 6 · B 9 · A 6
IssuedClassViolationCorrect by
Oct 29, 2026BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHDec 3, 2026
Oct 29, 2026BApt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED AT CEILING AND NORTH WALL GREATER THAN 10 SQFT AND LESS THAN 30SQFT IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHDec 3, 2026
Oct 29, 2026BApt 6A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING AND NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHDec 3, 2026
Dec 30, 2024C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR AT BUILDING FRONT , 5th STORYJan 5, 2025
Dec 30, 2024C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE STONE PARAPET CAP AND MORTAR AT PARAPET WALL BUILDING FRONT , 6th STORYJan 5, 2025
Dec 30, 2024C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR AT PARAPET WALL AT BUIDING FRONT , 6th STORYJan 5, 2025
Dec 30, 2024C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR AT BUILDING FRONT EXTERIOR , 6th STORYJan 5, 2025
Jan 18, 2023BApt 1B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD MOLDING AT DOOR TO REAR YARD IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTHFeb 22, 2023
Sep 24, 2009AApt 2A · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED CEILING 2 STY NORTHWEST APT 2A AT SOUTHWEST ROOM. , SECTION '' ''Dec 28, 2009
Sep 24, 2009C§ 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RATS REAR YARD AND CELLAR ER1.Sep 30, 2009
Sep 24, 2009AApt 2A · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACCOUSTICAL TILE CEILING CENTER ROOM 2 STY NORTHWEST APT 2A , SECTION '' ''Dec 28, 2009
Sep 24, 2009BApt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL KITCHEN 2 STY NORTHWEST APT 2A. , SECTION '' ''Oct 29, 2009
Sep 24, 2009B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER AT 3 4 & 5 STYS REAR FIRE ESCAPE.Oct 29, 2009
Sep 24, 2009A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.Dec 28, 2009
Sep 24, 2009CApt 2A · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RAT 2 STY NORTHWEST APT 2A THROUGHOUT. , SECTION '' ''Sep 30, 2009
Sep 24, 2009AApt 2A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF OFFENSIVE ODOR COMMING FROM KITCHEN SINK 2 STY NORTHWEST APT 2A. , SECTION '' ''Dec 28, 2009
Sep 24, 2009AApt 2A · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING INSTALLED IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHDec 28, 2009
Sep 24, 2009AApt 2A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHDec 28, 2009
Sep 24, 2009BApt 3C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY SOUTH APT 3C BRAEDY. LOCATED AT APT 3COct 29, 2009
Sep 24, 2009BApt 3B · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 3 STY NORTHEAST APT 3B. , SECTION '' ''Oct 29, 2009
Sep 24, 2009BApt 2A · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE 2 STY NORTHWEST APT 2A. , SECTION '' ''Oct 29, 2009

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 29, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED AT CEILING AND NORTH WALL GREATER THAN 10 SQFT AND LESS THAN 30SQFT IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 29, 2026HPD B§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING AND NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen