Brooklyn · Block 3252 · Lot 17 · 11221

642 Kosciuszko Street

3 floors · 6 apartments · 4,500 sq ft · built 1931 · class C2 · owner of record: Victor Crespo

52open violations
$12,500ECB/OATH penalties owed
9HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-23 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01

Open violations

ECB / OATH (10) · $12,500 owed
IssuedViolationHearingBalance
Oct 1, 2026Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED UNPERMITTED ELECTRICAL WORK DONE THROUGH OUT BUILDING. NO PERMITS OR FILING ON DOB NOW. CONDITIONS POSE ELECTRICAL SAFETY AND SHOCK HAZARD. ECB ISSUED FOR WORK WITHOUT ELECTRICAL
#39206406R
Dec 9, 2026
PENDING
$2,500
Oct 1, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED INSTALLED MEZZANINE AT FRONT OF APT 3L. NO FILING OR DOCUMENTS ON DOB NOW FOR ADDITIONAL SPACE CREATED. ECB ISSUED FOR CONSTRUCTION WORK WITHOUT PERMIT., OBTAIN PERMIT
#39206407Z
Dec 9, 2026
PENDING
$2,500
Sep 23, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED TWO NEW GAS WATER HEATERS INSTALLED IN CELLAR. NO PERMITS ON FILE FOR TIME OF INSTALLATION. ECB ISSUED FOR WORKING WITHOUT PERMIT., OBTAIN PERMIT
#39205272X
Dec 2, 2026
PENDING
$2,500
Sep 23, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED STORAGE OF ITEMS AT UNSAFE DISTANCE TO ELECTRICAL METERS, AND UNSAFE AMOUNT OF GARBAGE BEING STORED IN REAR YARD, AND ITEMS BEING STORED IN HALLWAY. CONDITIONS POSES POTENTIAL SH
#39205274J
Dec 2, 2026
PENDING
$2,500
Sep 23, 2026Plumbing CLASS - 2
AT TIME OF INSPECTION, OBSERVED REGULAR 90 DEGREE PVC INSTALLED AT WASTE LINE INSTEAD OF SWEEP 90 DEGREE PVC. INSTALLED PIPING DOES NOT HAVE THE GRADUAL SLOPE TO ALLOW FOR SMOOTH WASTE DISCHARGE. ECB ISSUED FOR
#39205283L
Dec 2, 2026
PENDING
$1,250
Sep 23, 2026Plumbing CLASS - 2
AT TIME OF INSPECTION, OBSERVED BULGING UNSHIELDED, ALL-RUBBER FLEXIBLE COUPLINGS INSTALLED AT WASTE LINE. THIS MATERIAL IS IMPROPER FOR INSTALLATION AS IT MAY LEAK OR BURST ECB ISSUED FOR IMPROPER PLUMBING MAT
#39205282J
Dec 2, 2026
PENDING
$1,250
Apr 30, 2010Construction CLASS - 1
FAILURE TO CORRECT CONDITIONS CITED IN NOV 34769206N FOR WORK DONE W/O A PERMIT CREATED APT AT CELLAR REM: CORRECT CONDITIONS CITED
#34846343M
Jan 19, 2011
WRITTEN OFF
$0
Nov 19, 2009Construction CLASS - 1
UNLAWFUL ACTS FAILURE TO COMPLY WITH COMMISSIONER ORDER TO CORRECT CONDITIONS CITIED IN 34769206N FOR CREATING APT AT CELLAR W/O A PERMIT REMEDY-CORRECT CONDITIONS CITIED.
#34821831K
Jan 19, 2011
WRITTEN OFF
$0
Jul 17, 2009Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR DOB RECORDS DOB MDR #330762 INDICATES PREMISES TO BE LEGALLY APPROVED FOR A 6FAMILY CELLAR BOILER & STORAGE NOW PREMISES CONVERTED TO BE A 7FAMILY
#34796207P
Mar 8, 2010
WRITTEN OFF
$0
Jul 17, 2009Construction CLASS - 1
WORK W/O A PERMIT WORK NOTED AT CELLAR LVL ERECTED FULL HEIGHT PARTITIONS CREATING 5RM INSTALLED WATER & WASTE LINES FOR A 3PC BATH SINK TOILET SHOWER RESIDENTIAL SINK & GAS LINE FOR STOVE REM: OBTAIN PERMITS O
#34796206N
Mar 23, 2010
WRITTEN OFF
$0
DOB (7)
IssuedViolationStatus
Jun 12, 2026CONSTRUCTION
DOB SUMMONS ISSUED DUE TO EXTENSIVE FIRE SMOKE AND WATER DAMAGE TO APARTMENTS 2L & 3L ALONG WITH DAMAGE TO THE EXTERIOR VINYL SIDING AND ROOF AS WELL AS MULTIPLE DAMAGED WINDOWS.
#26-01556
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#08791
DOB VIOLATION - ACTIVE
Feb 24, 2017LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
#06776
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#12542
DOB VIOLATION - ACTIVE
Jun 1, 1994LOCAL LAW 62/91 - BOILERS

#05629
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#22697
DOB VIOLATION - ACTIVE
Jun 1, 1993LOCAL LAW 62/91 - BOILERS

#05628
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Sep 16, 2026Structurally Compromised Buildings FTF-SC-INITL
Report due for structurally compromised property
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Feb 24, 2017Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
Active
Jan 31, 2005Boiler LL6291
Active
Jun 1, 1994Boiler LL6291
Active
Jun 1, 1993Boiler LL6291
Active
HPD (29) · C 9 · B 9 · A 9
IssuedClassViolationCorrect by
Jun 24, 2026I§ 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS # 2L UNDER VACATE ORDER # 260839 IN THE ENTIRE APARTMENT LOCATED AT APT, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST—
Jun 24, 2026I§ 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS # 3L UNDER VACATE ORDER # 260839 IN THE ENTIRE APARTMENT LOCATED AT APT, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST—
Oct 20, 2026AApt 3L · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CEILING DROPPED AND SPIRALED STAIRCASE INSTALLED CREATING A BEDROOM ABOVE ANOTHER (DUPLEX). IN THE 1st ROOM FROM NORTH LOCATED AT APT 3L, 3Jan 23, 2027
Oct 20, 2026AApt 3L · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE. IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTJan 23, 2027
Oct 20, 2026CApt 3L · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 26, 2026
Sep 25, 2026AApt 2L · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTDec 29, 2026
Sep 25, 2026CApt 2L · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOct 1, 2026
Jun 24, 2026BApt 2R · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 29, 2026
Jun 24, 2026CApt 3L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE AT WALLS, CEILING, WINDOWS BROKEN AND PLYWOOD SEALED. IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTJun 30, 2026
Jun 24, 2026AApt 1L · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EASTSep 27, 2026
Jun 24, 2026AApt 2R · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTSep 27, 2026
Jun 24, 2026AApt 3R · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTSep 27, 2026
Jun 24, 2026AApt 3L · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTSep 27, 2026
Jun 24, 2026BApt 1L · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJul 29, 2026
Jun 24, 2026BApt 2R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 29, 2026
Jun 24, 2026BApt 1L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJul 29, 2026
Jun 24, 2026BApt 1L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, AND ALL WALLS IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJul 29, 2026
Jun 24, 2026BApt 1L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, SOUTH AND EAST WALL IN THE BATHROOM LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJul 29, 2026
Jun 24, 2026AApt 2L · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTSep 27, 2026
Jun 24, 2026BApt 1L · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT ATCEILING IN THE BATHROOM LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJul 29, 2026
Jun 23, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 3rd STORYSep 26, 2026
Jun 23, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING AT PUBLIC HALL, 3rd STORYJul 28, 2026
May 15, 2017B§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING MINIMUM REQUIRED 100 WATTS (LIGHT FIXTURE PRESENT) AT FRONT AREAWAY, 1st STORYJun 19, 2017
Aug 18, 1987CApt 3L · D26-12.01 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT EAST & WEST WALLS 3 STY EAST APT 3L CENTER SOUTH ROOM VELEZ 919 4666. LOCATED AT APT 3LSep 7, 1987
Aug 18, 1987CApt 3L · D26-12.01 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT EAST WALL 3 STY EAST APT 3L CENTER NORTH ROOM VELEZ 919 4666. LOCATED AT APT 3LSep 7, 1987
Aug 18, 1987CApt 3R · D26-12.01 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILINGS CENTER NORTH ROOM 3 STY WEST APT 3R SCOTTBURGH 919 1705. LOCATED AT APT 3RSep 7, 1987
Aug 18, 1987CApt 3L · D26-12.01 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING 3 STY EAST APT 3L CENTER SOUTH ROOM VELEZ 919 4666. LOCATED AT APT 3LSep 7, 1987
Aug 18, 1987CApt 3R · D26-12.01 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILINGS SOUTH ROOM 3 STY WEST APT 3R SCOTTBURGH 919 1705. LOCATED AT APT 3RSep 7, 1987
Aug 18, 1987CApt 3L · D26-12.01 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING 3 STY EAST APT 3L SOUTH ROOM VELEZ 919 4666. LOCATED AT APT 3LSep 7, 1987

Issued in the last 120 days

DateSourceWhatNow
Oct 20, 2026HPD A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CEILING DROPPED AND SPIRALED STAIRCASE INSTALLED CREATING A BEDROOM ABOVE ANOTHER (DUPLEX). IN THE 1st ROOM FROM NORTH LOCATED AT APT 3L, 3Open
Oct 20, 2026HPD A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE. IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Oct 20, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Oct 1, 2026ECBUnknown: AT TIME OF INSPECTION, OBSERVED UNPERMITTED ELECTRICAL WORK DONE THROUGH OUT BUILDING. NO PERMITS OR FILING ON DOB NOW. CONDITIONS POSE ELECTRICAL SAFETY AND SHOCK HAZARD. ECB ISSUED FOR WORK WITHOUT ELECTRICALOpen
Oct 1, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED INSTALLED MEZZANINE AT FRONT OF APT 3L. NO FILING OR DOCUMENTS ON DOB NOW FOR ADDITIONAL SPACE CREATED. ECB ISSUED FOR CONSTRUCTION WORK WITHOUT PERMIT., OBTAIN PERMITOpen
Sep 25, 2026HPD A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF GAS RANGE CONVERTED TO ELECTRIC RANGE IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Sep 25, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Sep 23, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED TWO NEW GAS WATER HEATERS INSTALLED IN CELLAR. NO PERMITS ON FILE FOR TIME OF INSTALLATION. ECB ISSUED FOR WORKING WITHOUT PERMIT., OBTAIN PERMITOpen
Sep 23, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED STORAGE OF ITEMS AT UNSAFE DISTANCE TO ELECTRICAL METERS, AND UNSAFE AMOUNT OF GARBAGE BEING STORED IN REAR YARD, AND ITEMS BEING STORED IN HALLWAY. CONDITIONS POSES POTENTIAL SHOpen
Sep 23, 2026ECBPlumbing: AT TIME OF INSPECTION, OBSERVED REGULAR 90 DEGREE PVC INSTALLED AT WASTE LINE INSTEAD OF SWEEP 90 DEGREE PVC. INSTALLED PIPING DOES NOT HAVE THE GRADUAL SLOPE TO ALLOW FOR SMOOTH WASTE DISCHARGE. ECB ISSUED FOROpen
Sep 23, 2026ECBPlumbing: AT TIME OF INSPECTION, OBSERVED BULGING UNSHIELDED, ALL-RUBBER FLEXIBLE COUPLINGS INSTALLED AT WASTE LINE. THIS MATERIAL IS IMPROPER FOR INSTALLATION AS IT MAY LEAK OR BURST ECB ISSUED FOR IMPROPER PLUMBING MATOpen
Sep 16, 2026DOB SafetyStructurally Compromised Buildings: Report due for structurally compromised propertyOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 11:55 AM ET. BBL 3032520017.

Look up another building