Queens · Block 7083 · Lot 1 · 11365

64-41 Utopia Parkway

2 floors · 59,329 sq ft · built 1957 · class M9 · owner of record: Jewish Institute Of Queens

2open violations
$11,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-10-12 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 1 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 59,329 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 7083). Agency page

Dec 31, 2033
in 2623 days
Next due 2033

Open violations

ECB / OATH (6) · $11,000 owed
IssuedViolationHearingBalance
Jul 19, 2026Construction CLASS - 2
OBSERVED AT EXPOSURE#1 FRONT APPROXIMATELY 10 YARDS OF COMBUSTIBLE CONSTRUCTION MATERIAL THROUGHOUT ACCESSIBLE TO PUBLIC MAKING IT HAZARDOUS CONDITION. MAINTAIN HOUSING KEEPING., MAINTAIN ADEQUATE CONSTRUCTION
#39196687X
Dec 1, 2026
PENDING
$1,250
Jul 19, 2026Construction CLASS - 2
JOB SITE FENCE CONSTRUCTED AT EXPOSURE#1 FRONT MISSING SECTIONS AND STATE OF DISREPAIR., COMPLY WITH CODE; MAKE REPAIRS AS PER CODE.
#39196688H
Dec 1, 2026
$1,000
Oct 1, 2025Construction CLASS - 1
AT THE TIME OF INSPECTION OF A 3-STORY BUILDING, I OBSERVED ACTIVE JOB SITE. AT THE FIRST-FLOOR BALCONY, THE GUARDRAIL SYSTEM WAS INADEQUATE, CREATING A 9-FOOT FALL HAZARD. AT THE ELEVATOR LANDING AT EXP# 4, A
#39545495Y
Mar 8, 2027
$5,000
Sep 26, 2025Unknown CLASS - 2
MISCELLANEOUS VIOLATIONS.ATOI I OBSERVED SEVERAL INSTALLED SUPPORTED SCAFFOLDS AT EXPOSURE#2,#4 AND ROOF LEVEL OF THE PREMISES;THAT DID NOT MEET CODE SPECIFICATION-MISCELLANEOUS VIOLATION-BC 3314.1 MISSING TOE
#39545377N
Mar 8, 2027
$2,500
Sep 26, 2025Construction CLASS - 2
FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATIONS.ATOI I OBSERVED YODOCK BARRICADES IN THE PUBLIC ROADWAY AT EXP#1 NOT COMPLETELY CONNECTEDAND NOT FILLED WITH WATER.THIS POSES HAZARD FOR VEHICULAR TRAFFIC.REM:
#39545378P
Mar 8, 2027
$1,250
Jun 3, 2010Construction CLASS - 3
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS. JOB #410126402/AZ DATED 4.15.09 OF WHICH PERMIT EXPIRED 6.28.09.NON-CONFORMING WORK NOTED: 1) PLAN SHOWS SEVEN SPRINKLER HEADS IN THE
#34849081P
Jul 27, 2010
DEFAULT
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Jul 19, 2026ECBConstruction: OBSERVED AT EXPOSURE#1 FRONT APPROXIMATELY 10 YARDS OF COMBUSTIBLE CONSTRUCTION MATERIAL THROUGHOUT ACCESSIBLE TO PUBLIC MAKING IT HAZARDOUS CONDITION. MAINTAIN HOUSING KEEPING., MAINTAIN ADEQUATE CONSTRUCTIONOpen
Jul 19, 2026ECBConstruction: JOB SITE FENCE CONSTRUCTED AT EXPOSURE#1 FRONT MISSING SECTIONS AND STATE OF DISREPAIR., COMPLY WITH CODE; MAKE REPAIRS AS PER CODE.Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 6:16 PM ET. BBL 4070830001.