Manhattan · Block 1998 · Lot 13 · 10027

635 West 131 Street

2 floors · 16,000 sq ft · built 1940 · class G1 · owner of record: Trustees Of Columbia University In The C Ity Of New

4open violations
$6,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
45dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 45 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)

Open violations

ECB / OATH (2) · $6,250 owed
IssuedViolationHearingBalance
Jun 9, 2026Unknown CLASS - 1
AT TIME OF INSPECTION OBSERVED MANY CRACKS IN STRUCTURE AND COLUMN NEAR EXIT IS IN DISREPAIR CONDITION ALSO FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #35693654L ISSUED ON 05-03-2025 FOR FAILURE T
#39191854L
Feb 12, 2027
PENDING
$6,250
May 3, 2025Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 2 LEVELS(2 STORY BUILDING), OBSERVED(A) AT EXPOSURE #2 1ST FLOOR HORIZONTAL
#35693654L
Jun 1, 2026
ADMIT/IN-VIO
$0
DOB (1)
IssuedViolationStatus
May 3, 2025CONSTRUCTION
EMERGENCY WORK-OBSV CRACKED CONC @ BEAMS & SEPARATION JOINTS @ BRICK WALLS,HORIZONTAL CRACKED BEAM @ EXP2,1FL,CRACKED COLUMN @ EXP1,2FL CAUSING AN IMMED HAZ TO VEHICULAR TRAFFIC REQUIRING IMMED SAFETY MEASURES T/BE IMPLEMENTED. OWNER TO RETAIN A NYS REG DESIGN PROF TO DIRECT&SERV THE IMMED INSTALLAT
#PS109JL01
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 23, 2026Parking Structures FTF-PS-INITL
Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026DOB SafetyParking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 1:45 AM ET. BBL 1019980013.