Brooklyn · Block 8173 · Lot 24 · 11236

633 East 104 Street

5 floors · 86,763 sq ft · built 1975 · class I7 · owner of record: 615 East 104 Holdings Llc

18open violations
$3,625ECB/OATH penalties owed
1HPD class C (immediately hazardous)
166dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 86,763 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 166 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 166 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 18 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1141 days
Next cycle year 2029
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 8173). Agency page

Dec 31, 2033
in 2602 days
Next due 2033
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-22 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8) · $3,625 owed
IssuedViolationHearingBalance
Nov 4, 2026Elevators CLASS - 2
CLASS 2 RTS: DEVICE FOUND IN A NON COMPLIANT CONDITION REQUIRING RETURN TO SERVICE. AS PER 1 RCNY 11 02 AND BC 3001.2. REMEDY: RESTORE DEVICE TO FULL CODE COMPLIANT OPERATION AND VERIFY ALL SAFETY FUNCTIONS.
#39210452J
Jan 13, 2027
PENDING
$625
Oct 30, 2026Construction CLASS - 2
AT TIME OF INSPECTION, I OBSERVED FOUR NON-CLOSING FIRE RATED EXIT DOORS 1: FROM 1ST FLOOR KITCHEN INTO HALLWAY 2: 1ST FLOOR EXIT DOOR @EXP#2 AND 3: FROM BASEMENT TO REAR PARKING LOT @EXP#3. THEN, ANOTHER ONE D
#39210130R
Jan 13, 2027
PENDING
$625
Oct 30, 2026Boilers CLASS - 3
LAARS BOILER HAS THE COMBUSTION AIR FAN+OUTSIDE INLET SCREEN 1/2 CLOGGED;CORRECT VIOLATION+SUBMIT CERTIFICATE OF CORRECTION
#39210194X
Jan 13, 2027
PENDING
$500
Jul 13, 2026Elevators CLASS - 2
RESTORE DEVICE TO SERVICE (8.6.5.8.)
#39195803J
Sep 16, 2026
IN VIOLATION
$625
May 8, 2026Elevators CLASS - 2
INOPERATIVE CAR PHONE (2.27.1.1.3)
#39187832Z
May 6, 2027
PENDING
$625
May 8, 2026Elevators CLASS - 2
INOPERATIVE CAR PHONE (2.27.1.1.3)
#39187833K
May 6, 2027
PENDING
$625
Nov 26, 2025Construction CLASS - 2
OBSERVED IN THE CELLAR A UNION INSTALLED ON THE GAS LINE, A SPRINKLER HEAD INSTALLED BACKWARDS , LACK OF SPRINKLER COVERAGE IN THE STORAGE ROOM AND PVC PIPING USED ON WASHING MACHINES WASTE LINES WHICH IS CONTR
#39168479N
Feb 4, 2026
STIPULATION/IN-VIO
$0
Feb 21, 2018Unknown CLASS - 2
ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN ELECTRICAL CLOSETS IN CORRIDOR C ON 5TH, 3RD AND 1ST FLOORS ELECTRICAL PANELS AND BRUNCH WIRING TO VARIOUS LOCATIONS ON THE FLOORS. I OBSERVED OPEN CEILINGS AND WAL
#35311917H
Jul 2, 2018
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (9)
IssuedViolationStatus
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
HPD (1) · C 1 · B 0 · A 0
IssuedClassViolationCorrect by
Dec 24, 2020CApt 203 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE 1st ROOM FROM EAST LOCATED AT B-ROOM 203, 2nd STORY, 3rd B-ROOM FROM NORTH AT EASTJan 19, 2021

Issued in the last 120 days

DateSourceWhatNow
Nov 4, 2026ECBElevators: CLASS 2 RTS: DEVICE FOUND IN A NON COMPLIANT CONDITION REQUIRING RETURN TO SERVICE. AS PER 1 RCNY 11 02 AND BC 3001.2. REMEDY: RESTORE DEVICE TO FULL CODE COMPLIANT OPERATION AND VERIFY ALL SAFETY FUNCTIONS.Open
Oct 30, 2026ECBConstruction: AT TIME OF INSPECTION, I OBSERVED FOUR NON-CLOSING FIRE RATED EXIT DOORS 1: FROM 1ST FLOOR KITCHEN INTO HALLWAY 2: 1ST FLOOR EXIT DOOR @EXP#2 AND 3: FROM BASEMENT TO REAR PARKING LOT @EXP#3. THEN, ANOTHER ONE DOpen
Oct 30, 2026ECBBoilers: LAARS BOILER HAS THE COMBUSTION AIR FAN+OUTSIDE INLET SCREEN 1/2 CLOGGED;CORRECT VIOLATION+SUBMIT CERTIFICATE OF CORRECTIONOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 5:33 PM ET. BBL 3081730024.