| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 48,400 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 166 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 166 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 410 days | Next cycle year 2027 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 3, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BLDG. OBSRVED ON EXPSURE 1 N.ELEV: CRACKS IN BRICK WORK AT SEVERAL SPANDRELS ON THE 1ST FLOOR. (WHERE SHED WAS BLOCKING.) EXPOSURE 2 E.ELEVATION: SPALLING AND MISSING BRICK AT THE 4FLOOR HEIGHT & PARAPET NEAR THE NORTH EAST END OF ELEVATION; VERTICAL; CRACK IN BRICK JOINT. REMEDY #SR1203RF | DOB VIOLATION - ACTIVE |
| Mar 25, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED CRACKED BRICK WORK MASONRY PUSHING OFF SHELF ANGLES ON EXPOSURE 1 NORTH ELEVATION. ALSO SPALLED/SPALLING BRICK WORK ON EXPOSURE 2 EAST ELEVATION. REMEDY: REPAIR AND/OR REPLACE #SR11201XN | DOB VIOLATION - ACTIVE |
| Nov 13, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00033 | DOB VIOLATION - ACTIVE |
| Oct 3, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE: OBSERVED AT EXP#2 (NORTH ELEV) BULGING MASONRY AT NE CORNER FROM 4TH TO 2ND FL WINDOW;DETERIORATING WINDOW LINTELS; ALSO OBSERVED MASONRY PUSHING OFF SHELF ANGLES AT MULTIPLE LOCATIONS. REMEDY: FIX AND/OR REPLACE #SR11203YK | DOB VIOLATION - ACTIVE |
| May 14, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE:OBSERVED AT EXP1 NORTH ELEV BULGING MASONRY AT NE CORNER FROM 4TH TO 2ND FLOOR CRACKS AROUND 1ST FL & 2ND FLOOR.DETERIORATING WINDOW LINTELS.ALSO OBS ERVED MASONRY PUSHING OFF SHELF ANGLES AT MULTIPLE LOCATION ON EXP1.RE MEDY:FIX AND/OR RE #SR11201YK | DOB VIOLATION - ACTIVE |
| Dec 1, 2023 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2300517 | DOB VIOLATION - ACTIVE |
| May 2, 2023 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00350 | DOB VIOLATION - ACTIVE |
| May 2, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01040 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| Nov 13, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 1, 2023 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |