Manhattan · Block 626 · Lot 24 · 10014

630 Hudson Street

4 floors · 6 apartments · 6,160 sq ft · built 1847 · class S5 · owner of record: 630 Hudson Llc

17open violations
$9,400ECB/OATH penalties owed
2HPD class C (immediately hazardous)
52dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 52 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 52 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-16 (Accepted). Agency page

Dec 31, 2026
in 52 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 68 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 296 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1148 days
Next cycle year 2029

Open violations

ECB / OATH (5) · $9,400 owed
IssuedViolationHearingBalance
Sep 3, 2025Construction CLASS - 1
ATOI, OBSERVED AT REAR OF BUILDING 2ND MEANS OF EGRESS IS OBSTRUCTED BY A FENCE ERECTED BY ADJACENT PROPERTY THAT BLOCK ALL ACCESS INTO 53 JANE ST REAR YARD. DROP DOWN LADDER FROM FIRE ESCAPE WHERE TENANTS WILL
#39159382M
Dec 11, 2025
DEFAULT
$6,250
Jun 30, 2022Construction CLASS - 3
FENCE EXCEEDS PERMITTED HEIGHT. AT TIME OF INSPECTION, OBSERVED A WOODEN FENCE ERECTED HIGHER THAN THE 6' PERMITTED HEIGHT BETWEEN PROPERTIES IN THE REAR YARD. FENCE IS ATTACHED BY A WOOD SLAT THAT IS AFFIXED T
#39065032P
Apr 13, 2023
IN VIOLATION
$25
Sep 17, 2021Plumbing CLASS - 2
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. EXHAUST DISCHARGE MUST BE NO CLOSER THAN 10 FEET FROM BUILDING OPENINGS ÝPER RS13(2-2.1.4); MC 401.5.2¨ AS PER MC 501.2 AND RS 13-1 SEC. 2-2.1.4. AT TIME
#39047890M
Sep 8, 2022
IN VIOLATION
$0
Mar 5, 2021Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39034270Z ISSUED ON 01/05/21 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.
#35526840R
May 20, 2021
DEFAULT
$3,125
Jul 29, 2019Unknown CLASS - 1
UNAPPROVED,UNSAFE,UNSUTIABLE ELECTRICAL EQUIPMENT APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE.THE ENTIRE BASEMENT TEMPORARY WIRING ARE NOT PROPERLY SUPPORTED AROUND CABLES ARE NOT PROPERLY SUPPORTED
#35359947L
Sep 26, 2019
IN VIOLATION
$0
DOB (4)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#02394
DOB VIOLATION - ACTIVE
Sep 5, 2025CONSTRUCTION
ATOI, OBSERVED AT REAR OF BUILDING 2ND MEANS OF EGRESS IS OBSTRUCTED BY A FENCE ERECTED BY ADJACENT PROPERTY THAT BLOCK ALL ACCESS INTO 53 JANE ST REAR YARD. DROP DOWN LADDER FROM FIRE ESCAPE WHERE TENANTS WILL USE IN CASE OF EMERGENCY HAVE NOW HAVE BEEN COMPROMISED. THESE CONDITIONS MAKE ALL REAR U
#25-02085
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#08500
DOB VIOLATION - ACTIVE
Jul 5, 2022CONSTRUCTION
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: IN REAR YARD, WOODEN SIX FOOT FENCE ERECTED BY ADJACENT BUILDING 53 JANE ST. IS BLOCKING REQUIRED SECOND MEANS OF EGRESS FOR THREE REAR APARTMENTS AND EATING AND DRINKING ESTABLISHMENT ON GROUND FLOOR.
#22-02076
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (6) · C 2 · B 3 · A 1
IssuedClassViolationCorrect by
Aug 17, 2023B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATIRAL AT CEILING AT PUBLIC HALL, 5th STORYSep 21, 2023
Mar 6, 2020A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BLACONIES AT REAR YARDJun 9, 2020
Mar 6, 2020B§ 53,187,231 M/D LAW & DEPT RULES & REG. PROVIDE MEANS OF EGRESS FROM YARD TO STREET BY FIREPROOF PASSAGEWAY FOR WHICH APPLICATION MUST BE FILED FOR APPROVAL,OR BY UNLOCKED DOOR OR GATE IN FENCE TO ADJOINING PREMISES WITH CONSENT OF ADJACENT OWNER.Apr 10, 2020
Mar 6, 2020C§ 27-2005 ADM CODE PROVIDE FIRE GUARD UNTIL FENCE AT REAR YARD IS REMOVED WHICH IS BLOCKING EGRESSMar 14, 2020
Mar 6, 2020C§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 4 SLATS AT CATWALK LOCATED AT REAR YARDMar 14, 2020
Mar 6, 2020B§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT REAR YARDApr 10, 2020

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 9, 2026, 4:39 PM ET. BBL 1006260024.

Look up another building