5 floors · 16 apartments · 10,000 sq ft · built 1900 · class C7 · owner of record: 63 Crmn Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-15 (Accepted). Agency page | Dec 31, 2026 in 61 days | 1 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1157 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 12, 2024 | Construction CLASS - 2 WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED A 1-STORY WOOD-FRAMED ROOF STRUCTURE, APPROXIMATELY 8' D X 8' H X 24' L ATTACHED TO BUILDING REAR, EXPOSURE 3. WOOD-FRAME ROOFED STRUCTURE IS SAFETY HAZARD #39130023L | Apr 30, 2026 IN VIOLATION | $1,250 |
| Nov 12, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED COMBUSTIBLE WOOD STRUCTURE AT REAR IS SAFETY HAZARD BLOCKING FIRE ESCAPES AND SECONDARY MEANS OF EGRESS FOR RESTAURANT ON #39130021H | Apr 30, 2026 IN VIOLATION | $1,250 |
| Jul 6, 2021 | Boilers CLASS - 2 ILLEGAL DRAFT INDUCER INSTALLED ON BOILER/ENGINEERS CHIMNEY AFFIDAVIT REQUIRED VERIFYING CAPABILITY + INTEGRITY OF CHIMNEY; CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION #39043939X | Aug 26, 2021 DEFAULT | $0 |
| Jul 6, 2021 | Boilers CLASS - 2 NO CLEANOUT DOOR AT BASE OF CHIMNEY/PIPE LEAKING ABOVE BOILER ROOM DOOR/OUTSIDE INLET TO BOILER ROOM FRESH AIR DUCT IS 1/2 BLOCKED BY LOUVER/STORAGE IN BOILER ROOM/ STORAGE IN GAS METER ROOM/ CORRECT VIOLATION #39043940N | Aug 26, 2021 DEFAULT | $0 |
| Jun 12, 2013 | Unknown CLASS - 1 ELECTRICAL WORK W/O A PERMIT. GROUND FLR BAR RESTAURANT DENNCHY'S NO APP ON FILE FOR ELECTRICL SIGN "STELLA" ARTOIS. RMDY:OBTAIN PERMIT. #35021308R | Aug 29, 2013 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 1997 | CONSTRUCTION #B2GS05 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 19, 2013 | A | Apt 3B · § 27-2005 ADM CODE REFIT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 3B, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 22, 2013 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 31, 2026, 4:26 PM ET. BBL 1005820041.