7 floors · 113,400 sq ft · built 2024 · class R0 · owner of record: 625 New York 2022 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 60 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 113,400 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 181 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 181 days | Annual filing |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page | Feb 21, 2028 in 477 days | No Cycle 10 report on record yet |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4810). Agency page | Dec 31, 2030 in 1521 days | Next due 2030 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 15, 2025 | Unknown CLASS - 1 ATOI OBSERVED THE MODEL APARTMENT IN APT 2G TO SHOW IT TO POTENTIAL BUYERS OR TO TAKE PHOTOS FOR ADVERTISING. THE APARTMENT WAS FULLY FURNISHED . UPON REQUEST FOR TENANT PROTECTION PLAN NONE WAS PROVIDED CONTRA #39543788Z | Jun 5, 2026 IN VIOLATION | $1,250 |
| Aug 15, 2025 | Construction CLASS - 2 ATOI OBSERVED THE MODEL APARTMENT IN APT 2G TO SHOW IT TO POTENTIAL BUYERS OR TO TAKE PHOTOS FOR ADVERTISING. THE APARTMENT WAS FULLY FURNISHED. TO GET THERE, POTENTIAL BUYERS HAD TO WALK THROUGH THE LOBBY IN A #39543789K | Jun 5, 2026 IN VIOLATION | $1,250 |
| May 28, 2025 | Cranes and Derricks CLASS - 2 AT TIME OF INSPECTION, OBSERVED ACTIVE JOBSITE WITH SUSPENDED SCAFFOLD IN PLACE. DEPARTMENT RECORDS SHOW NO NOTIFICATION RECEIVED. CONTRARY TO CODE 3314.4.1.5. FAILURE TO NOTIFY 24 TO 48 HOURS PRIOR TO INSTALLA #39540729P | Mar 12, 2027 | $2,500 |
| May 28, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED AT EXPOSURE 1, FACADE WORK OVER 40 FEET WITH A SIDEWALK SHED THAT FAILED TO FULLY COVER THE REQUIRED PROTECTED AREA PER CODE 3307.6.2. INADEQUATE COVERAGE PUTS PEDESTRIANS AT RIS #39540738R | Mar 12, 2027 | $5,000 |
| May 28, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED WORKERS ON A LEADING EDGE WITH NO FALL PROTECTION, INCLUDING GUARDRAIL SYSTEMS, IN VIOLATION OF CODE 3308.7. THIS CREATES A SEVERE RISK OF FATAL FALLS TO WORKERS AND POTENTIAL IN #39540739Z | Mar 12, 2027 | $5,000 |
| Feb 4, 2025 | Unknown CLASS - 2 BC 3307.2.1 DOT PERMITS: AT TIME OF INSPECTION I OBSERVED THAT THERE WAS A DEBRIS DUMPSTER WITHIN THE STORAGE WORK ZONE OF SITE 625 NEW YORK AVE, IN FRONT OF THE ADJACENT PROPERTY AT 631 NEW YORK AVE. DOT PERMI #39536576L | May 15, 2026 IN VIOLATION | $2,500 |
| Jan 8, 2024 | Construction CLASS - 1 FAILURE TO INSTITUTE SAFETY MEASURE AT TEMPORARY CONSTRUCTION. AT TIME OF INSPECTION OBSERVED NO GUARD-RAILING AROUND EXCAVATED AREA WHERE REQUIRED, NO EXIT STAIR FROM EXCAVATED AREA.; BC3301.2, COMPLY WITH COD #39102943X | Mar 19, 2026 IN VIOLATION | $625 |
| Jan 8, 2024 | Unknown CLASS - 1 AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION/EXCAVATION WORK, WHERE ADJACENT BUILDING AT EXP#3 FOUNDATION WALL EXPOSED NOT WATERPROOFED , ALSO GARAGE FOUNDATION WALL EXPOSED. STOP ALL WORK 3 FEET FROM ENT #39102944H | Mar 19, 2026 IN VIOLATION | $1,250 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 11:29 AM ET. BBL 3048107501.