4 floors · 12 apartments · 9,360 sq ft · built 1928 · class C1 · owner of record: 622 East 235th Street Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 409 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-13 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 3, 2012 | B | Apt 5 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL RETURN INTERCOM BUZZER. IN THE FOYER LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTH | Feb 7, 2012 |
| Jan 3, 2012 | B | Apt 5 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTH | Feb 7, 2012 |
| Jan 3, 2012 | B | Apt 5 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTH | Feb 7, 2012 |
| Jan 3, 2012 | B | Apt 5 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PILOT LIGHT AT GAS RANGE IN THE KITCHEN LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTH | Feb 7, 2012 |
| Oct 29, 2009 | B | § 27-2005 ADM CODE PROVIDE (IN THE EVENT OF A POWER OUTAGE) AN ACCEPTABLE HEAVY DUTY LOCK AND LATCH SET ON THE ENTRANCE DOOR TO THE BUILDING , 1st STORY | Dec 3, 2009 |
| Oct 29, 2009 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED ON THE ENTRANCE DOOR TO THE BUILDING , 1st STORY | Nov 4, 2009 |
| Oct 29, 2009 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING PADLOCKABLE SLIDE BOLT INSTALLED ON THE BULKHEAD DOOR | Nov 4, 2009 |
| Jun 10, 2008 | A | D26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX NOTICE MISSING. | Sep 13, 2008 |
| Apr 18, 2006 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER NORTH STACK AT FIRE ESCAPE, 2nd STORY | Jul 27, 2006 |