Manhattan · Block 2098 · Lot 47 · 10031

620 West 152 Street

5 floors · 26 apartments · 22,115 sq ft · built 1920 · class C1 · owner of record: 620 West 152 Streetassociates,

11open violations
$2,500ECB/OATH penalties owed
5HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 49 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 49 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 49 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 65 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-21 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
May 2, 2026Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED AT THE TIME OF INSPECTION I OBSERVED FLOWER POTS ON THE 2ND AND 5TH FLOOR FIRE ESCAPES AT EXPOSURE 1. THE PLACEMENT OF THESE ITEMS OBSTRUCTS THE EXIT PASSA
#35727063M
Jan 4, 2027
PENDING
$2,500
DOB (2)
IssuedViolationStatus
May 2, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTED AT TIME OF INSPECTION,I OBSERVED AT EXP1 CRACKS ON BRICKS AND DETERIORATED MOR TAR JOINTS ON MULTIPLE LOCATIONS,CORRODED WINDOW LINTELS AND CRACKED W INDOW SILLS AND DAMAGED PARAPET.AT EXP4 CRACKS OBSERVED ON PARAPET ARE A AND SPALLING BR
#SR10901JR
DOB VIOLATION - ACTIVE
Mar 19, 2025CONSTRUCTION
FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES IN A CO DE COMPLIANT MANNER.AT TIME OF INSPECTION,IT WAS OBSERVED AT EXP1 NORT H ELEV CRACKED BRICKS,DAMAGED WINDOW LINTELS,CRACKED WINDOW SILLS,DETE RIORATED MORTAR JOINTS AND IMPROPERLY SUPPORTED AC UNITS.AT EXP2 & 4 EAST & WEST ELE ,S
#SR10901MA
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Jun 15, 2026AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
HPD (5) · C 5 · B 0 · A 0
IssuedClassViolationCorrect by
Oct 10, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT FIRE EXIT DOOR TO EAST YARD IN THE PUBLIC HALL LOCATED AT PUBLIC PARTS, 1st STORY, 1st PUBLIC PARTS FROM NORTH AT EASTOct 24, 2025
Nov 1, 2022CApt 23 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 15 SQ FT AT WEST WALL, SOUTH WALL, EAST WALL, NORTH WALL, CEILING IN THE BATHROOM LOCATED AT APT 23, 5th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 13117403 ISSUED 11-JUN-19 HAS BEEN UPNov 27, 2022
Feb 23, 2021CApt 23 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL APPOX 30 SQ. FT. IN THE 5th ROOM FROM NORTH LOCATED AT APT 23, 5th STORY, 1st APARTMENT FROM NORTH AT EASTMar 21, 2021
Jun 17, 2019CApt 23 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 23, 5Jul 15, 2019
Feb 6, 2019CApt 8 · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING IN THE BATHROOM LOCATED AT APT 8, 2nd STORY, APARTMENT AT EASTFeb 27, 2019

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 12, 2026, 12:22 AM ET. BBL 1020980047.