Queens · Block 3626 · Lot 2 · 11385

62-15 Catalpa Avenue

3 floors · 6 apartments · 5,724 sq ft · built 1930 · class C2 · owner of record: Catalpa Apartments Llc

11open violations
$7,300ECB/OATH penalties owed
1HPD class C (immediately hazardous)
45dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 45 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-12-05 (Accepted). Agency page

Dec 31, 2026
in 45 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 61 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 289 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1141 days
Next cycle year 2029

Open violations

ECB / OATH (3) · $7,300 owed
IssuedViolationHearingBalance
May 18, 2026Construction CLASS - 2
MULTIPLE DWELLING NOW CONVERTED AT CELLAR LEVEL TO SLEEPING QUARTERS WITH 1 BEDROOM, 3 PC BATHROOM, AND LIVING SPACE. NO SECOND MEANS OF EGRESS, INSUFFICIENT LIGHT AND VENTILATION. NO FIRE SUPPRESSION SYSTEM.,
#39189001R
Jan 19, 2027
PENDING
$1,250
May 31, 2024Construction CLASS - 2
ATOI, OBSERVED ON ROOFTOP FOUR MOUNTED CONDENSER UNITS AND FLOORS 1 THRU 3 HAVE INDOOR MOUNTED HVAC MINI-SPLIT A/CS IN MULTIPLE ROOMS. DEPARTMENT RECORDS SHOW NO MECHANICAL PERMIT FILED FOR THIS SCOPE OF WORK.,
#39115660Z
Feb 24, 2025
IN VIOLATION
$1,250
May 24, 2024Unknown CLASS - 1
ATOI, OBSERVED NEW ELECTRICAL PANELS, NEW JUNCTION BOXES AND NEW UNTERMINATED WIRING FOR POWER, LIGHT & SWITCHING ON ALL 3 FLOORS/6 APTS UNDERGOING FULL RENOVATION. WORK WAS NOT PERFORMED BY A MASTER ELECTRICAN
#39115243H
Aug 25, 2026
IN VIOLATION
$4,800
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#17286
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#22062
DOB VIOLATION - ACTIVE
Mar 1, 2013LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
#14605
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Mar 1, 2013Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Active
HPD (3) · C 1 · B 2 · A 0
IssuedClassViolationCorrect by
Jun 17, 2026B§ 53,187,231 M/D LAW & DEPT RULES & REG. PROVIDE MEANS OF EGRESS FROM YARD TO STREET BY FIREPROOF PASSAGEWAY FOR WHICH APPLICATION MUST BE FILED FOR APPROVAL,OR BY UNLOCKED DOOR OR GATE IN FENCE TO ADJOINING PREMISES WITH CONSENT OF ADJACENT OWNER.Jul 22, 2026
Apr 20, 2026CApt 1R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EASTMay 16, 2026
Oct 10, 2025B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 3rd STORYNov 14, 2025

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 5:38 PM ET. BBL 4036260002.

Look up another building