Manhattan · Block 389 · Lot 54 · 10009

613 East 6 Street

6 floors · 14 apartments · 10,896 sq ft · built 1920 · class C6 · owner of record: 613 East 6th St Owners Corp

8open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
43dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 774 days
Next cycle year 2028

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Apr 27, 2022Construction CLASS - 2
FAILURE TO MAINTAIN BLDG WALLS&APPURTENANCES.OBSERVED #OF CRACKED,DAMAGED MASONRY UNITS ON FRONT EXP&LONG VERT CRACK@PARAPET ALONG SE CORNEROF BLDG.ALTHO ALL THOSE DEFECTIVE CONDITIONS WERE NOTED IN QEWI SWARMP
#35651286L
Feb 2, 2023
IN VIOLATION
$0
Mar 28, 2008Local Law Non-Hazardous
FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LL 11/98REPORT. REMEDY: FILE AND AMENDED REPORT FOLLOWING REMEDIAL REPAIRS OF
#34684074Y
Jun 19, 2008
DEFAULT
$0
DOB (1)
IssuedViolationStatus
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00069
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
HPD (4) · C 2 · B 2 · A 0
IssuedClassViolationCorrect by
May 20, 2014BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINIMUM OF 100 WATTS INCANDESCENT LIGHT REQUIRED. LIGHT FIXTURE PRESENT. AT FRONT AREAWAYJun 24, 2014
May 5, 2014BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINIMUM OF 100 WATTS INCANDESCENT LIGHT REQUIRED, FIXTURE PRESENT. AT FRONT AREAWAYJun 9, 2014
Jul 2, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL AND ON BOILER ROOM DOOR.Jul 8, 2008
Jul 2, 2008CD26-17.10 ADM CODE PROVIDE READY ACCESS TO BUILDING'S HEATING SYSTEM CELLAR DOOR LOCKED.Jul 8, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 7:14 AM ET. BBL 1003890054.

Look up another building