Brooklyn · Block 5794 · Lot 75 · 11220

6128 8 Avenue

class G7 · owner of record: Twrlr Tower Llc

9open violations
$68,750ECB/OATH penalties owed
0HPD class C (immediately hazardous)
—no dated deadlines found

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

We couldn't find building attributes for this lot, so no deadlines are listed.

Open violations

ECB / OATH (18) · $68,750 owed
IssuedViolationHearingBalance
Sep 27, 2026Unknown CLASS - 1
MISCELLANEOUS VIOLATIONS.BC 3303.3 ATOI OF A 28 STORY NB AT ROOF,BUILDING APPROXIMATELY 132329 SQ F SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITIES.UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR
#39559826R
Dec 2, 2026
PENDING
$5,000
Sep 27, 2026Construction CLASS - 2
FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AT TIME OF INSPECTION,OBSERVED THE JOBSITE WAS NOT ADEQUATELY SECURED,WITH AN UNPROTECTED AND READILY ACCESSIBLE OPENING PROVIDIN
#39559827Z
Dec 2, 2026
PENDING
$5,000
Aug 21, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF AN 15RCNY 20-04 28-STORY NEW BUILDING AND ACTIVE JOB SITE, A FIRE HYDRANT WAS OBSERVED IN USE WITHOUT BACKFLOW PREVENTION. THIS CONDITION POSES A HAZARD TO THE PUBLIC WATER SUPPLY
#39558200K
Oct 28, 2026
$2,500
Aug 20, 2026Construction CLASS - 1
BC-3305.3.6.1.2. FAILURE TO SECURE RE-SHORES IN PROXIMITY TO UNENCLOSED PERIMETERS.-AS NOTED: AT THE TIME OF INSPECTION OF A 28 STORY NEW BUILDING ACTIVELY INSTALLED FORMWORKS FOR ROOF FLOOR CONCRETE SLAB; I OB
#35730887M
Oct 28, 2026
PENDING
$2,500
Aug 16, 2026Unknown CLASS - 2
BC 3307.2 AT INSPECTION OF A 28-STORY NEW BUILDING, A CONCRETE WASHOUT BOX WAS OBSERVED IN A STORAGE ZONE AT EXP#1, WITH FENCING MISSING AND UNRESTRICTED PUBLIC ACCESS. THIS CREATES A HAZARDOUS CONDITION TO PUB
#39557967L
May 10, 2027
$2,500
Aug 16, 2026Unknown CLASS - 2
28 STORY NB INACTIVE JOBSITE, WITH A BUILDING FOOTPRINT, (SQ. FT.)132329 WALK PERIMETERS, KNOCK & CALLED OUT, I OBSERVED NO COMPETENT WATCH PERSONNEL AS PER BC 3303.7.7.6 A WATCHPERSON REQUIREMENTS OF SECTION 3
#39557965H
May 10, 2027
PENDING
$2,500
Aug 16, 2026Unknown CLASS - 2
BC 3308.6.1.4 28-STORY NEW BUILDING, PROTECTIVE SCAFFOLD AT EXP# 1 WAS OBSERVED INCOMPLETE, WITH A SECTION APPROXIMATELY 4 FLOORS BELOW THE WORKING DECK. THIS CONDITION CREATES A HAZARD TO PUBLIC AND PROPERTY.
#39557964X
May 10, 2027
$2,500
Aug 16, 2026Construction CLASS - 2
BC 330.1.1.3 I OBSERVED YODOCK SYSTEM IN PLACE WITH MISSING INTERLOCKING COUPLERS THROUGHOUT, AND NOT FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNINTENDED MOVEMENT OF THE BARRIERS INCREAS
#39557966J
May 10, 2027
$1,250
Jun 26, 2026Construction CLASS - 2
WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED MECHANICAL WORK BEING PERFORMED WITHOUT MS PW2 FILED ON DOB SYSTEM., OBTAIN ALL PERMITS; PLEASE SUBMIT PERMIT TO ENERGYCODEINSPECTIONS@BUILDINGS.NYC.GOV
#39193924R
Apr 20, 2027
$1,250
Jun 14, 2026Unknown CLASS - 2
(3301.1.2) AT TIME OF INSPECTION OBSERVED 28 STORY MAJOR BUILDING WITH ONGOING WORK. WHEN ASKED FOR THE FIRE SAFETY MANAGER AS REQUIRED BY NYC FIRE CODE (1408.1) THERE WAS NONE ON SITE . SITE SAFETY MANAGER LIC
#39555465M
Apr 6, 2027
$2,500
Jun 4, 2026Unknown CLASS - 1
. A WORKER FELL FROM AN OPENING WHILE COVERING COPPER HVAC PIPES ON THE 9TH FLOOR OF A 28-STORY NB SITE. PERMIT HOLDER, JOB NO.B00754062-I1-GC, FAILED TO SUBMIT REPORT WITHIN 3 BUSINESS DAYS OF REQUIRED 16 ITEM
#39555048L
Mar 9, 2027
$10,000
May 26, 2026Unknown CLASS - 1
BC 3306.9.10.3. RESPONDING TO AN INCIDENT WHERE A WORKER FELL FROM AN OPENING AT THE 9 FL TO THE 8 FL WHILE COVERING HVAC PIPES. THE FLOOR OPENING COVER WAS NOT ADEQUATELY SECURED AGAINST DISPLACEMENT, CAUSING
#39554629P
Mar 30, 2027
$5,000
May 23, 2026Unknown CLASS - 2
BC 3303.3. ATOI OF A 28 STORY NEW BUILDING AT ROOF, BUILDING APPROXIMATELY 132329 SQ F. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WAT
#39554556N
Mar 30, 2027
PENDING
$2,500
May 23, 2026Unknown CLASS - 2
AT TIME OF INSPECTION, OBSERVED EQUIPMENT STORED IN THE PUBLIC ROADWAY ADJACENT TO THE JOB SITE SIDEWALK SHED AND COVERED WITH A SOLID TARP, AFFECTING PUBLIC VISIBILITY AND NOT IN COMPLIANCE WITH BUILDING CODE
#39554557P
Mar 30, 2027
$2,500
Jan 24, 2026Unknown CLASS - 2
BC3303.3.ATOI OF A 28 STORY NEW BUILDING AT ROOF, BUILDING APPROXIMATELY 132329 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALER
#39549485Z
Nov 9, 2026
$2,500
Jan 4, 2026Construction CLASS - 2
BC 3301.1.3: AT THE TIME OF MY INSPECTION, I OBSERVED YODOCK BARRIER SYSTEMS INSTALLED WITH MISSING INTERLOCKING COUPLERS THROUGHOUT AND NOT FILLED WITH WATER OR SAND. THESE CONDITIONS CREATE A POTENTIAL HAZARD
#39548731K
Apr 12, 2027
$1,250
Oct 28, 2025Construction CLASS - 2
AT THE TIME OF MY INSPECTION OF A 28 STORY BUILDING AT FOUNDATION, RESPONDING TO AN INCIDENT THAT WORKERS FELL FROM DECKING. INVESTIGATION REVEAL THAT WORKERS WERE POURING CONCRETE ON DECKING WHEN IT COLLAPSED,
#39546433N
Apr 16, 2027
$5,000
Oct 28, 2025Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.AS NOTED:OBSERVED MAJOR FORMWORK FAILURE AT 1ST FLOOR LEVEL WHERE 4 WORKERS WERE INJURED.UPON REVIEW OF FORMWORK AND SHORINGS
#35718000K
Feb 25, 2027
$12,500
DOB (3)
IssuedViolationStatus
Jun 16, 2026CONSTRUCTION
FTC-VIO#072125CEU31012PW(#3A22465)ORDERED TWRLR TOWER LLC TO HAVE EOR REVIEW NON-CONFORMANCE OF CONCRETE TESTING PROCEDURE & SUBMIT S&S ACCEPTANCE STATEMENT W/ ALT TESTING RESULTS BY 9/12/25.AS OF 6/15/26, TWRLR TOWER LLC HAS NOT COMPLIED WITH COMMISSIONER'S ORDER.REMEDY: COMPLY W/ COMMISSIONER'S OR
#CEU31010PW
DOB VIOLATION - ACTIVE
Jul 21, 2025CONSTRUCTION
FAILURE TO PERFORM STANDARD-CURING SPECIMENS: DURING LAB INSPECTION @ HRF ON 7/1/2025, DOB OBSERVED DRY CYLINDERS STORED IMPROPERLY, NOT MEETING FINAL CURING REQUIREMENTS. REMEDY:.COMPLY WITH CODES AND ASTM SUBMIT EOR-APPROVED ALTERNATE RESULTS BY 09/12/2025
#CEU31012PW
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#31735
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 25, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 27, 2026ECBUnknown: MISCELLANEOUS VIOLATIONS.BC 3303.3 ATOI OF A 28 STORY NB AT ROOF,BUILDING APPROXIMATELY 132329 SQ F SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITIES.UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOROpen
Sep 27, 2026ECBConstruction: FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AT TIME OF INSPECTION,OBSERVED THE JOBSITE WAS NOT ADEQUATELY SECURED,WITH AN UNPROTECTED AND READILY ACCESSIBLE OPENING PROVIDINOpen
Sep 25, 2026DOB SafetyAEUHAZ: Open
Aug 21, 2026ECBConstruction: AT THE TIME OF INSPECTION OF AN 15RCNY 20-04 28-STORY NEW BUILDING AND ACTIVE JOB SITE, A FIRE HYDRANT WAS OBSERVED IN USE WITHOUT BACKFLOW PREVENTION. THIS CONDITION POSES A HAZARD TO THE PUBLIC WATER SUPPLYClosed
Aug 20, 2026ECBConstruction: BC-3305.3.6.1.2. FAILURE TO SECURE RE-SHORES IN PROXIMITY TO UNENCLOSED PERIMETERS.-AS NOTED: AT THE TIME OF INSPECTION OF A 28 STORY NEW BUILDING ACTIVELY INSTALLED FORMWORKS FOR ROOF FLOOR CONCRETE SLAB; I OBOpen
Aug 19, 2026ECBConstruction: AT THE TIME OF MY INSPECTION OF A 28-STORY NEW BUILDING, DEBRIS WAS OBSERVED THROUGHOUT THE SITE, INCLUDING THE 26TH, 27TH, AND 28TH FLOORS. THIS CONDITION CREATES A HAZARD TO WORKERS, THE PUBLIC, AND PROPERTY,Closed
Aug 16, 2026ECBUnknown: BC 3307.2 AT INSPECTION OF A 28-STORY NEW BUILDING, A CONCRETE WASHOUT BOX WAS OBSERVED IN A STORAGE ZONE AT EXP#1, WITH FENCING MISSING AND UNRESTRICTED PUBLIC ACCESS. THIS CREATES A HAZARDOUS CONDITION TO PUBClosed
Aug 16, 2026ECBUnknown: 28 STORY NB INACTIVE JOBSITE, WITH A BUILDING FOOTPRINT, (SQ. FT.)132329 WALK PERIMETERS, KNOCK & CALLED OUT, I OBSERVED NO COMPETENT WATCH PERSONNEL AS PER BC 3303.7.7.6 A WATCHPERSON REQUIREMENTS OF SECTION 3Open
Aug 16, 2026ECBUnknown: BC 3308.6.1.4 28-STORY NEW BUILDING, PROTECTIVE SCAFFOLD AT EXP# 1 WAS OBSERVED INCOMPLETE, WITH A SECTION APPROXIMATELY 4 FLOORS BELOW THE WORKING DECK. THIS CONDITION CREATES A HAZARD TO PUBLIC AND PROPERTY.Closed
Aug 16, 2026ECBConstruction: BC 330.1.1.3 I OBSERVED YODOCK SYSTEM IN PLACE WITH MISSING INTERLOCKING COUPLERS THROUGHOUT, AND NOT FILL WITH WATER/SAND WHICH POSES A POTENTIAL HAZARD BY ALLOWING UNINTENDED MOVEMENT OF THE BARRIERS INCREASClosed
Jul 10, 2026ECBConstruction: WORK DOES NOT CONFORM TO PLANS. AT TIME OF INSPECTION, APPROVED DOB ENERGY AND ARCHITECTURAL DRAWINGS CALLS OUT WINDOW TYPE W-01R TO HAVE U-VALUE OF .27 OPERABLE AND .26 FIXED. UPON INSPECTION, WINDOWS THAT AREClosed
Jul 8, 2026DOB SafetyAEUHAZ: Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 6:41 AM ET. BBL 3057940075.

Look up another building