Manhattan · Block 2134 · Lot 105 · 10032

611 West 156 Street

6 floors · 29 apartments · 44,742 sq ft · built 1910 · class D4 · owner of record: 611 West 156 St Housi

51open violations
$24,380ECB/OATH penalties owed
6HPD class C (immediately hazardous)
45dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 45 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 61 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 44,742 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 166 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 166 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 289 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 410 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-01 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (9) · $24,380 owed
IssuedViolationHearingBalance
Aug 16, 2024Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTES:(1)SPALLING BALCONY MASONRY NEAR ROOF LEVEL OF EXPOSURE #1(SOUTH). (2)CRACKED/DISPLACE BRICK MASONRY AT ROOF LEVEL/PARAPET OF EXP #4(EAST).
#35683963X
Dec 11, 2026
DEFAULT
$5,630
Jun 20, 2024Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: HAZARDOUS CONDITION OBSERVED AT TOP LEVEL BALCONY EXPSOURE #1(SOUTH), SPALLING/CRACKED TERRA-COTTA/MASONRY. REMEDY: MAINTAIN EXTERIOR FACADE
#35685417H
Feb 13, 2025
DEFAULT
$12,500
Jun 20, 2024Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NOTE: ECB#35682239K REQUIRED OWNER TO MAINTAIN EXTERIOR FACADE AND TAKE SAFETY MEASURES AS PER 1RCNY 103-04 VIO DATED 05/16/2024. AS OF 06/20/2024 NO SUCH REPAIRS OR
#35685418J
Feb 13, 2025
DEFAULT
$6,250
Mar 7, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS(S) OR APPURTENANCES. NOTE:-AT THE TIME OF INSPECTION OBSERVED AT EXPOSURE #4 EAST ELEVATION BULGED MASONARY/PARAPET LEVEL. REMEDY: MAINTAIN BUILDING EXTERIOR WALL(S)
#35682239K
May 16, 2024
IN VIOLATION
$0
Mar 12, 2021Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K3 OF THE 2014 BUILDING CODE. REMEDY: INSTALL DLM , FILE AND PERFORM TEST WITH NYC DOB
#39037837Y
Jun 17, 2021
ADMIT/IN-VIO
$0
Oct 24, 2014Elevators CLASS - 2
07M07,70M07,61L07,68V01,05F01. 07M07-PROVIDE DOOR RESTRICTOR; 70M07- PROVIDE SUMP PUMP COVER IN PIT; 61L07-PROVIDE GROUND ON MAIN LINE; 08V01-ADJUST LEVELING; 05F01-ADJUST CAR DOORS TO FALL OPEN.
#38233372P
Dec 11, 2014
ADMIT/IN-VIO
$0
Jul 26, 1995Elevators Hazardous
46T,48T,49T,75U,73O,2X,74M,3M,42X,57R. 74 CAR DATA PLATE. 3 SAFETY KEY HOLE. 42 LIMITS. 57 WIRE PUMP *CEASE USE UNTIL DRUM LIMITS ARE WO-RKING CALL 312-8730 BEFORE RETURNING TO SERVICE.
#38050836M
Oct 5, 1995
WRITTEN OFF
$0
Aug 24, 1994Elevators Non-Hazardous
46T,48T,49T,50F,50Y,37G,73O,31Q,33O,18E,74X,37(20AMP)74 HAVE ELEV ANS ALL CALL
#38043918K
Dec 22, 1994
IN VIOLATION
$0
Mar 19, 1992Elevators Non-Hazardous
08V,13I,22D,29M,46T,49T,55M,57O,58J,36T,33O,37G,54M, 29- BRIFFER 54- ELEVATION CO. NAME.
#38023469X
Apr 30, 1992
WRITTEN OFF
$0
DOB (12)
IssuedViolationStatus
Aug 21, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00037
DOB VIOLATION - ACTIVE
Jun 20, 2024CONSTRUCTION
PARTIAL VACATE ORDER 06.20.2024 DUE TO DEFECTIVE FACADE. MULTIPLE HAZARDOUS CONDITIONS SUCH AS CRACKED BULDING AND DISPLACED BRICK MASONRY @ EXPOSURE #4 (EAST) HAVE THEREFORE MADE THE COURTYARD AT EAST UNABLE TO BE OCCUPIED. REMEDY, VACATE ENTIRE COURTYARD @ EXPOSURE 4 (EAST) COURTYARD TO BE USED IN
#FA11201RM
DOB VIOLATION - ACTIVE
May 15, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00038
DOB VIOLATION - ACTIVE
Aug 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00451
DOB VIOLATION - ACTIVE
May 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00451
DOB VIOLATION - ACTIVE
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#03433
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#04281
DOB VIOLATION - ACTIVE
Sep 1, 1994LOCAL LAW 62/91 - BOILERS

#04958
DOB VIOLATION - ACTIVE
Mar 18, 1994LOCAL LAW 62/91 - BOILERS

#19860
DOB VIOLATION - ACTIVE
Mar 18, 1993LOCAL LAW 62/91 - BOILERS

#19860
DOB VIOLATION - ACTIVE
Apr 7, 1992LOCAL LAW 10/81 - ELEVATOR
1
#02091
DOB VIOLATION - ACTIVE
Jun 29, 1990LOCAL LAW 10/81 - ELEVATOR
1
#02319
DOB VIOLATION - ACTIVE
DOB NOW Safety (14)
IssuedViolationStatus
Oct 8, 2026GHG Emissions - LL97 FTF-EN-LL97321
FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B).
Active
Jun 24, 2026GHG Emissions - LL97 FTF-EN-LL97321
Active
Aug 21, 2024AEUHAZ FTC-AEU-HAZ
Active
May 15, 2024AEUHAZ FTC-AEU-HAZ
Active
Aug 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Sep 6, 2019Elevators ACC1
Active
May 20, 2019Elevators EVCAT5
Active
Jan 26, 2018Elevators ACC1
Active
Sep 1, 1994Boiler LL6291
Active
Mar 18, 1994Boiler LL6291
Active
Mar 18, 1993Boiler LL6291
Active
Apr 7, 1992Elevators LL1081
Active
Jun 29, 1990Elevators LL1081
Active
HPD (17) · C 6 · B 10 · A 1
IssuedClassViolationCorrect by
Apr 7, 2025BApt 4 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMay 12, 2025
Oct 13, 2022CApt 4 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTHOct 19, 2022
Aug 18, 2022AApt 4 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTHNov 21, 2022
Aug 18, 2022BApt 4 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTHSep 22, 2022
Apr 7, 2022BApt 4 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMay 12, 2022
Jan 24, 2022C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM ... AT PUBLIC HALL, 1st STORYJan 30, 2022
Mar 29, 2021C§ 27-2005 ADM CODE PROVIDE IN THE EVENT OF A POWER OUTAGE AN ACCEPTABLE HEAVY DUTY LOCK AND LATCH SET AT VESTIBULE DOOR. AT PUBLIC HALL, 1st STORYApr 4, 2021
Mar 29, 2021C§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCK SET INSTALLED AT VESTIBULE DOOR. AT PUBLIC HALL, 1st STORYApr 4, 2021
Jul 16, 2020BApt 22 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE radiator shutoff valve IN THE 5th ROOM FROM NORTH AT EAST LOCATED AT APT 22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHAug 20, 2020
Jul 16, 2020BApt 22 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR defective IN THE ENTIRE APARTMENT LOCATED AT APT 22, 2nd STORYAug 20, 2020
Jul 16, 2020CApt 22 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 22, 2nd STORYAug 11, 2020
Mar 28, 2019B§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE SADDLE AT DOOR OPENING AT PUBLIC HALL, 1st STORY, SECTION ''WEST''May 2, 2019
Mar 28, 2019B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF STEEL GATE ERECTED AT STAIRS LEADING TO ROOF AT PUBLIC HALL, 6th STORYMay 2, 2019
Dec 3, 2018BApt 4 · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 7, 2019
Jul 2, 2018BApt 41 · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 41, 4th STORY, 1st APARTMENT FROM NORTH AT EASTAug 6, 2018
Jul 2, 2018CApt 41 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR TO FIRE ESCAPE WINDOW. IN THE 1st ROOM FROM NORTH LOCATED AT APT 41, 4th STORY, 1st APARTMENT FROM NORTH AT EASTJul 10, 2018
Jul 2, 2018BApt 41 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, AND WALLS. IN THE 1st ROOM FROM NORTH LOCATED AT APT 41, 4th STORY, 1st APARTMENT FROM NORTH AT EASTAug 6, 2018

Issued in the last 120 days

DateSourceWhatNow
Oct 8, 2026DOB SafetyGHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B).Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 5:03 AM ET. BBL 1021340105.

Look up another building