Brooklyn · Block 5523 · Lot 38 · 11204

6102 16 Avenue

2.5 floors · 2 apartments · 9,536 sq ft · built 1931 · class G9 · owner of record: Ilana Kahn Revocable Trust

28open violations
$3,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
63dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2022-12-27 (Accepted). Agency page

Dec 31, 2026
in 63 days
1 of 1 without an accepted 2026 report yet
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 307 days
Required only if the owner doesn't live there
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 428 days
Next cycle year 2027

Open violations

ECB / OATH (2) · $3,125 owed
IssuedViolationHearingBalance
Sep 12, 2018Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.NOTED:AT TIME OF INSPECTION WHERE CURRENT CERTIFICATE OF OCCUPANCY #99543 CLEARLY STATES THAT FLOOR USE OF ONE S
#35349624H
Mar 6, 2019
IN VIOLATION
$625
Sep 12, 2018Construction CLASS - 1
UNLAWFULLY STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.NOTED:AT TIMEOF INSPECTION FOUND AT PREMISES SETUP AND USED AS A AUTOMOTIVE BODY SHOP OBSERVED FLAMMABLE COMBUSTIBLE CONTAINER FULL STORED IN OPEN AREA O
#35308475M
Mar 6, 2019
IN VIOLATION
$2,500
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#14401
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#13169
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#08233
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
HPD (20) · C 0 · B 16 · A 3
IssuedClassViolationCorrect by
Jul 19, 2007ISECTION 27-2142 ADM CODE - THE PREMISES OR APTS. HAVE BEEN VACATED BY THE DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR ATTIC APT—
Jun 29, 2007BApt 3 · SECTION 27-2073 ADM CODE - DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE ATTIC IN THE ENTIRE APARTMENT LOCATED AT APT 3, 1st APARTMENT FROM WEST AT NORTHAug 8, 2007
Jun 29, 2007BApt 3 · SECTION 27-2077 ADM CODE - DISCONTINUE THE ROOMING UNIT ATTIC IN THE ENTIRE APARTMENT LOCATED AT APT 3, 1st APARTMENT FROM WEST AT NORTHAug 8, 2007
Jun 21, 2007BSECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE WEST COURT AND COURT AT NORTHJul 31, 2007
Jun 21, 2007BSECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES NORTH WALL COURT AT NORTHJul 31, 2007
Jun 6, 2007BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL WEST WALL AT PUBLIC HALL, 1st STORYJul 21, 2007
Jun 6, 2007AApt 2 · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING IN KITCHEN AND EAST 2 ROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT NORTHSep 19, 2007
Jun 6, 2007BApt 2 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, APARTMENT AT NORTHJul 21, 2007
Jun 6, 2007BApt 2 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, APARTMENT AT NORTHJul 21, 2007
Jun 6, 2007BApt 3 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE IMPROPERLY COUNTERBALANCED UPPER WINDOW SASH IN THE KITCHEN LOCATED AT APT 3, 3rd STORYJul 21, 2007
Jun 6, 2007AApt B2 · SECTION 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 19, 2007
Jun 6, 2007BApt 3 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE IMPROPERLY COUNTERBALANCED UPPER EAST WINDOW SASH IN THE 4th ROOM FROM EAST LOCATED AT APT 3, 3rd STORYJul 21, 2007
Jun 6, 2007BApt 3 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR IN THE BATHROOM LOCATED AT APT 3, 3rd STORYJul 21, 2007
Jun 6, 2007BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING SOUTH WALL AT PUBLIC HALL, 1st STORYJul 21, 2007
Jun 6, 2007ASECTION 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILINGS AND WALLS AT ALL STORIES AT PUBLIC HALLSep 19, 2007
Jun 6, 2007BApt 3 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 3, 3rd STORYJul 21, 2007
Jun 6, 2007BApt B2 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 21, 2007
Jun 6, 2007BApt B2 · SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 21, 2007
Jun 6, 2007BApt B2 · SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 21, 2007
Jun 6, 2007BApt 2 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 2, 2nd STORY, APARTMENT AT NORTHJul 21, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 1:14 AM ET. BBL 3055230038.