4 floors · 6 apartments · 6,750 sq ft · built 1920 · class S5 · owner of record: 61 5th Ave Management Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-11-04 (Accepted). Agency page | Dec 31, 2026 in 66 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 27, 2021 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH ORDER OF COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS #35547784Y INDOOR LIGHTING FIXTURES INSTALLED OUTDOORS UNDER CANOPY AND SUMMONS #35547786H WORK WITHOUT PERMIT I #35634111P | Feb 9, 2022 DEFAULT | $6,250 |
| Jul 29, 2021 | Construction CLASS - 1 UNLAWFUL ACT.FAILURE TO COMPLY W/ORDER OF COMMISSIONER FAILURE TO CORRECT&CERTIFY SUMMONS35547754Y&35547786H COMPLY W/CODE #35583757R | Dec 8, 2021 DEFAULT | $0 |
| Jun 24, 2021 | Construction CLASS - 2 INSTALLED CHIMNEY LINER WITH OUT A PERMIT, OBTAIN ALL PERMITS #39043435M | Feb 1, 2022 IN VIOLATION | $1,250 |
| Mar 17, 2021 | Unknown CLASS - 1 ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED AT 8AM BRANCH WIRING CIRCUITINSTALLED FOR ELECTRIC DRYER IN KITCHEN APARTMENT 4F.NO APPLICATION ONFILE FOR ELECTRICAL WORK.REMEDY:OBTAIN PERMIT. #35547786H | Dec 20, 2021 DEFAULT | $0 |
| Mar 17, 2021 | Construction CLASS - 2 I OBSERVED IN CELLAR AREA PVC PIPING FOR SANITARY PIPING USED IN A MIXED USE BUILDING WHICH IS PROHIBITED AND NOT CODE COMPLAINT, REPAIR AND/OR REPLACE #39037781Y | Jul 21, 2021 DEFAULT | $0 |
| Mar 17, 2021 | Unknown CLASS - 2 FAILURE TO PROVIDE COVER FACE PLATE LAMPHOLDERS LUMINARIE CANOPY FOR ELECTRICAL OUTLET.PANEL COVER AND TROUGH COVERS MISSING IN BASEMENT.REMEDY:COMPLY WITH CODE. #35547788L | Dec 20, 2021 DEFAULT | $0 |
| Mar 17, 2021 | Unknown CLASS - 1 UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT DEVICES,APPARATUS,APPLIANCES,MATERIALS OR WIRING IN USE.8 FOOT INDOOR FLORESCENT FIXTURE USED OUTDOOR UNDER CANOPY EXPOSED WIRING THROUGHOUT BASEMENT.DEFECTIVE #35547784Y | Dec 20, 2021 DEFAULT | $0 |
| Mar 17, 2021 | Unknown CLASS - 2 FAILURE TO PROVIDE ADEQUATE CIRCUIT OVERCURRENT PROTECTION DEVICE PER TABLE.NUMBER 12 THIN CONDUCTOR FUSED AT 30 AMPS IN APT 4F PANEL.REMED Y:PROVIDE ADEQUATE OVERCURRENT PROTECTION. #35547787J | Mar 18, 2022 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #07792 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #34160 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #13724 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #34814 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #11056 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 6) | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 21, 2024 | B | Apt 4R · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 25, 2024 |
| Oct 21, 2024 | B | Apt 4R · § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 25, 2024 |
| Oct 21, 2024 | C | Apt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 16, 2024 |
| Oct 21, 2024 | C | Apt 4R · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 4, 2024 |
| Oct 21, 2024 | B | Apt 4R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM BUILDING ENTRANCE TO WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 25, 2024 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 4:12 AM ET. BBL 3009330001.