Brooklyn · Block 933 · Lot 1 · 11217

61 5 Avenue

4 floors · 6 apartments · 6,750 sq ft · built 1920 · class S5 · owner of record: 61 5th Ave Management Llc

23open violations
$7,500ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-11-04 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual

Open violations

ECB / OATH (8) · $7,500 owed
IssuedViolationHearingBalance
Sep 27, 2021Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY WITH ORDER OF COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS #35547784Y INDOOR LIGHTING FIXTURES INSTALLED OUTDOORS UNDER CANOPY AND SUMMONS #35547786H WORK WITHOUT PERMIT I
#35634111P
Feb 9, 2022
DEFAULT
$6,250
Jul 29, 2021Construction CLASS - 1
UNLAWFUL ACT.FAILURE TO COMPLY W/ORDER OF COMMISSIONER FAILURE TO CORRECT&CERTIFY SUMMONS35547754Y&35547786H COMPLY W/CODE
#35583757R
Dec 8, 2021
DEFAULT
$0
Jun 24, 2021Construction CLASS - 2
INSTALLED CHIMNEY LINER WITH OUT A PERMIT, OBTAIN ALL PERMITS
#39043435M
Feb 1, 2022
IN VIOLATION
$1,250
Mar 17, 2021Unknown CLASS - 1
ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED AT 8AM BRANCH WIRING CIRCUITINSTALLED FOR ELECTRIC DRYER IN KITCHEN APARTMENT 4F.NO APPLICATION ONFILE FOR ELECTRICAL WORK.REMEDY:OBTAIN PERMIT.
#35547786H
Dec 20, 2021
DEFAULT
$0
Mar 17, 2021Construction CLASS - 2
I OBSERVED IN CELLAR AREA PVC PIPING FOR SANITARY PIPING USED IN A MIXED USE BUILDING WHICH IS PROHIBITED AND NOT CODE COMPLAINT, REPAIR AND/OR REPLACE
#39037781Y
Jul 21, 2021
DEFAULT
$0
Mar 17, 2021Unknown CLASS - 2
FAILURE TO PROVIDE COVER FACE PLATE LAMPHOLDERS LUMINARIE CANOPY FOR ELECTRICAL OUTLET.PANEL COVER AND TROUGH COVERS MISSING IN BASEMENT.REMEDY:COMPLY WITH CODE.
#35547788L
Dec 20, 2021
DEFAULT
$0
Mar 17, 2021Unknown CLASS - 1
UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT DEVICES,APPARATUS,APPLIANCES,MATERIALS OR WIRING IN USE.8 FOOT INDOOR FLORESCENT FIXTURE USED OUTDOOR UNDER CANOPY EXPOSED WIRING THROUGHOUT BASEMENT.DEFECTIVE
#35547784Y
Dec 20, 2021
DEFAULT
$0
Mar 17, 2021Unknown CLASS - 2
FAILURE TO PROVIDE ADEQUATE CIRCUIT OVERCURRENT PROTECTION DEVICE PER TABLE.NUMBER 12 THIN CONDUCTOR FUSED AT 30 AMPS IN APT 4F PANEL.REMED Y:PROVIDE ADEQUATE OVERCURRENT PROTECTION.
#35547787J
Mar 18, 2022
DEFAULT
$0
DOB (5)
IssuedViolationStatus
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#07792
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#34160
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#13724
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#34814
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#11056
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
HPD (5) · C 2 · B 3 · A 0
IssuedClassViolationCorrect by
Oct 21, 2024BApt 4R · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 25, 2024
Oct 21, 2024BApt 4R · § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 25, 2024
Oct 21, 2024CApt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 16, 2024
Oct 21, 2024CApt 4R · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 4, 2024
Oct 21, 2024BApt 4R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM BUILDING ENTRANCE TO WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 25, 2024