2 floors · 2 apartments · 2,200 sq ft · built 1915 · class B1 · owner of record: 9307 Dex Management Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 293 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 27, 2026 | Construction CLASS - 1 @TIME OF INSPECTION,OBSERVE PLUMBING&GAS SYSTEM+GAS FIXTURE FROM BASEMENT TO 2ND FLOOR COMPLETELY REMOVED W/ STRONG GAS SMELL IN BASEMENT&I VERIFIED PER DEPARTMENTS RECORDS THERE WERE NO PLUMBING/GAS PERMIT TO #39558460R | Dec 29, 2026 PENDING | $2,500 |
| Aug 27, 2026 | Construction CLASS - 1 @TIME OF INSPECTION IN RESPONSE TO COMPLAINT OF DEMOLITION OF GARAGE&PORCH OBSERVE GARAGE@REAR OF BUILDING HAD BEEN DEMOLISHED W/ ONLY CONCRETE PAD FOUNDATION REMAIN&I VERIFIED PER DOB RECORDS(BIS/DOB NOW)&PUBL #39558458H | Nov 10, 2026 PENDING | $5,000 |
| Aug 27, 2026 | Unknown CLASS - 1 OBSERVE EXISTING ELECTRICAL SYSTEM FROM BASEMENT TO 2ND FLOOR COMPLETELY REMOVED,ELECTRICAL PANEL UNCOVERED W/EXPOSED WIRES+CUT WIRES,UNSAFE TEMPORARY BY-PASS TO MAIN ELECTRICAL SYSTEM W/ EXTENSION CORD&I VERIF #39558459J | Dec 29, 2026 PENDING | $2,500 |
| Aug 27, 2026 | Unknown CLASS - 1 BC3303.2 UTILITIES.@TIME INSPECTION,OBSERVED MAIN GAS LINE SEVERELY DETERIORATED&NOT SAFEGUARDED+MAINTAINED W/SMELL OF GAS IN BASEMENT TO CODE BC3303.2.1 CREATING CATASTROPHIC SAFETY HAZARD AFFECTING ADJOIN PRO #39558461Z | Dec 29, 2026 PENDING | $5,000 |
| Aug 27, 2026 | Construction CLASS - 1 @PERMITTED&ACTIVE SITE OBSERVE STAIRS LEADING FROM 1ST FL TO 2ND FL&BASEMENT ALL MISSING HANDRAIL AS REQUIRED TO CODE BC1011.7+1011.11+28-105.12.4 CREATING HAZARDS OF FALL, AFFECTING EMERGENCY OPERATIONS,& HEAL #39558462K | Dec 29, 2026 PENDING | $2,500 |
| Aug 27, 2026 | Construction CLASS - 1 Q01424052.@PERMITTED&ACTIVE SITE OBSERVE WORK NOT CONFORM TO PLANS COMPROMISING STRUCTURAL STABILITY&AFFECTING HEALTH&LIFE SAFETY OF ALL-BASEMENT FULL DEMOLISHED W/ 1ST FL MAIN JOIST SUPPORT BEAMS COLUMN/POST R #39558463M | Dec 29, 2026 PENDING | $2,500 |
| Oct 3, 2014 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES (EXTERIOR). DEFECTS NOTED: AT LEFT HAND SIDE OF PREMISES,MISSING WOODEN TRIM FROM WINDOWS;PLUS ENTIRE MASONRY WALL AT EXP #2,LEFT HAND SIDE (EXP #2) STUCCO FALLIN #35026567Y | Apr 25, 2017 WRITTEN OFF | $0 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 27, 2026 | ECB | Construction: @TIME OF INSPECTION,OBSERVE PLUMBING&GAS SYSTEM+GAS FIXTURE FROM BASEMENT TO 2ND FLOOR COMPLETELY REMOVED W/ STRONG GAS SMELL IN BASEMENT&I VERIFIED PER DEPARTMENTS RECORDS THERE WERE NO PLUMBING/GAS PERMIT TO | Open |
| Aug 27, 2026 | ECB | Construction: @TIME OF INSPECTION IN RESPONSE TO COMPLAINT OF DEMOLITION OF GARAGE&PORCH OBSERVE GARAGE@REAR OF BUILDING HAD BEEN DEMOLISHED W/ ONLY CONCRETE PAD FOUNDATION REMAIN&I VERIFIED PER DOB RECORDS(BIS/DOB NOW)&PUBL | Open |
| Aug 27, 2026 | ECB | Unknown: OBSERVE EXISTING ELECTRICAL SYSTEM FROM BASEMENT TO 2ND FLOOR COMPLETELY REMOVED,ELECTRICAL PANEL UNCOVERED W/EXPOSED WIRES+CUT WIRES,UNSAFE TEMPORARY BY-PASS TO MAIN ELECTRICAL SYSTEM W/ EXTENSION CORD&I VERIF | Open |
| Aug 27, 2026 | ECB | Unknown: BC3303.2 UTILITIES.@TIME INSPECTION,OBSERVED MAIN GAS LINE SEVERELY DETERIORATED&NOT SAFEGUARDED+MAINTAINED W/SMELL OF GAS IN BASEMENT TO CODE BC3303.2.1 CREATING CATASTROPHIC SAFETY HAZARD AFFECTING ADJOIN PRO | Open |
| Aug 27, 2026 | ECB | Construction: @PERMITTED&ACTIVE SITE OBSERVE STAIRS LEADING FROM 1ST FL TO 2ND FL&BASEMENT ALL MISSING HANDRAIL AS REQUIRED TO CODE BC1011.7+1011.11+28-105.12.4 CREATING HAZARDS OF FALL, AFFECTING EMERGENCY OPERATIONS,& HEAL | Open |
| Aug 27, 2026 | ECB | Construction: Q01424052.@PERMITTED&ACTIVE SITE OBSERVE WORK NOT CONFORM TO PLANS COMPROMISING STRUCTURAL STABILITY&AFFECTING HEALTH&LIFE SAFETY OF ALL-BASEMENT FULL DEMOLISHED W/ 1ST FL MAIN JOIST SUPPORT BEAMS COLUMN/POST R | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 12, 2026, 3:42 AM ET. BBL 4027630016.