5 floors · 21 apartments · 17,980 sq ft · built 1930 · class C1 · owner of record: 610 West 178th Street Houseing Devel Fun D Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-18 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 1, 2025 | Boilers CLASS - 2 I FOUND A EASCO FST-50 WITH A HOLE IN THE FLUE PIPE/ GAUGE GLASS DIRTY/CORRECT ALL VIOLATING CONDITION /SUBMIT A CERTIFICATE OF CORRECTIONS #39155709R | Dec 7, 2026 DEFAULT | $6,250 |
| Issued | Violation | Status |
|---|---|---|
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #00248 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 31, 2025 | I | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WIL | — |
| Jun 11, 2026 | A | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING HEAT RISER IN THE 1st ROOM FROM EAST LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 14, 2026 |
| Jun 11, 2026 | B | Apt 4A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 16, 2026 |
| Feb 11, 2026 | C | Apt 5D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 17, 2026 |
| Feb 11, 2026 | C | Apt 5D · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 17, 2026 |
| Feb 9, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM, 3rd STORY | Feb 15, 2026 |
| Jan 6, 2026 | C | Apt 2B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AROUND THE RAISER AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 12, 2026 |
| Jan 6, 2026 | B | Apt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 10, 2026 |
| Jan 6, 2026 | A | Apt 2B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 11, 2026 |
| Dec 9, 2025 | B | Apt 4B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SHOWER HEAD IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 13, 2026 |
| Dec 8, 2025 | C | Apt 3B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAN ENAMEL AT BATHTUB IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 14, 2025 |
| Dec 8, 2025 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 12, 2026 |
| Dec 8, 2025 | B | Apt 3B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 12, 2026 |
| Nov 17, 2025 | A | Apt 2C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLOOR CERAMIC TILES IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Feb 20, 2026 |
| Oct 30, 2025 | C | Apt 2B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 5, 2025 |
| Oct 30, 2025 | A | Apt 2B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 2, 2026 |
| Oct 30, 2025 | A | Apt 2B · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION AT HEAT RISER IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 2, 2026 |
| Oct 30, 2025 | B | Apt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 4, 2025 |
| Oct 24, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Oct 30, 2025 |
| Oct 10, 2025 | C | Apt 3C · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT THE CEILING IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 3C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 16, 2025 |
| Oct 10, 2025 | B | Apt 2B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Oct 10, 2025 | B | Apt 2C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Oct 10, 2025 | C | Apt 2B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 16, 2025 |
| Oct 10, 2025 | B | Apt 1D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Nov 14, 2025 |
| Oct 10, 2025 | C | Apt 1D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 10, 2025 | C | Apt 1D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Nov 5, 2025 |
| Oct 10, 2025 | C | Apt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE BATHROOM. IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 16, 2025 |
| Oct 10, 2025 | C | Apt 1A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 16, 2025 |
| Oct 10, 2025 | B | Apt 2C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Oct 10, 2025 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 14, 2025 |
| Oct 10, 2025 | B | Apt 3C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Nov 14, 2025 |
| Oct 10, 2025 | C | Apt 5B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 5, 2025 |
| Oct 10, 2025 | C | Apt 3C · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRICAL OUTLET AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 16, 2025 |
| Oct 10, 2025 | C | Apt 3C · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRICAL OUTLET AT THE WEST WALL IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 3C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 16, 2025 |
| Oct 10, 2025 | C | Apt 5B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 5, 2025 |
| Sep 19, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT FRONT YARD | Sep 25, 2025 |
| Sep 11, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT FRONT YARD | Sep 17, 2025 |
| Aug 28, 2025 | A | Apt 2C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING LESS THAN 10 SQ. FEET IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 1, 2025 |
| Aug 28, 2025 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 2, 2025 |
| Aug 28, 2025 | B | Apt 3B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 2, 2025 |
| Aug 28, 2025 | B | Apt 2C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 2, 2025 |
| Aug 28, 2025 | C | Apt 2C · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRICAL OUTLET AT WEST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Sep 3, 2025 |
| Aug 28, 2025 | B | Apt 3B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THE CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 2, 2025 |
| Aug 28, 2025 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 2, 2025 |
| Aug 28, 2025 | B | Apt 3B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHEON PLATE AT CEILING AROUND HEAT RISER PIPE IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 2, 2025 |
| Aug 27, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING, AND WALLS AT BULKHEAD TO ROOF AT PUBLIC HALL STAIRS, 5th STORY | Oct 1, 2025 |
| Aug 27, 2025 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS AT PUBLIC HALL STAIRS, 5th STORY | Nov 30, 2025 |
| Jul 2, 2025 | B | Apt 5B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 6, 2025 |
| Jul 2, 2025 | B | Apt 5B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 6, 2025 |
| Jun 10, 2025 | C | Apt 5D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE AIR VALVE AT HEAT RISER PIPE IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 16, 2025 |
| Jun 10, 2025 | C | Apt 5D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 16, 2025 |
| Jun 10, 2025 | C | Apt 5D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 16, 2025 |
| May 5, 2025 | B | Apt 5B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRY DOOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 9, 2025 |
| May 5, 2025 | B | Apt 5B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRY DOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 9, 2025 |
| Apr 16, 2025 | A | Apt 5B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 20, 2025 |
| Apr 16, 2025 | C | Apt 5B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL, EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 5B, 5th ST | May 10, 2025 |
| Apr 16, 2025 | B | Apt 5B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | May 21, 2025 |
| Mar 10, 2025 | A | Apt 5B · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION HEAT RISER PIPE IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 13, 2025 |
| Mar 10, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND WALLS AT BULKHEAD AT PUBLIC HALL STAIRS, 5th STORY | Apr 14, 2025 |
| Mar 10, 2025 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS AT BULKHEAD AT PUBLIC HALL STAIRS, 5th STORY | Jun 13, 2025 |
Showing 60 of 121. Full list on the agency site.