Manhattan · Block 396 · Lot 10 · 10009

604 East 14th Street

17 floors · 616 apartments · 423,836 sq ft · built 1980 · class D6 · owner of record: Nyc Housing Authority

21open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
44dto Energy audit and retro-commissioning (2026)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 396). Agency page

Dec 31, 2026
in 44 days
Due this year
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 96 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 423,836 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 775 days
Next cycle year 2028

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Apr 10, 2026Elevators CLASS - 1
VF... R T S .. 97-X-17....ELEVATOR IN BUILDING OUT OF SERVICE UP ON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE ,REPAIR AND RESTORE TO SERVICE IMMEDIATELY...REINSPECTION REQUIRED...
#39184023P
May 20, 2026
POP/IN-VIO
$0
Mar 12, 2026Elevators CLASS - 2
CLASS 2 ITEM: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE.
#39180543K
May 21, 2026
POP/IN-VIO
$0
Mar 12, 2026Elevators CLASS - 1
CLASS 1 ITEM: FIREFIGHTERS SERVICE PHASE 2 INOPERATIVE. REPAIR.
#39180545Y
May 21, 2026
POP/IN-VIO
$0
Mar 12, 2026Elevators CLASS - 1
CLASS 1 ITEM: FIREFIGHTERS SERVICE PHASE 2 INOPERATIVE. REPAIR.
#39180544M
May 21, 2026
POP/IN-VIO
$0
Dec 2, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #900751.REMEDY:SUBMIT ACCEPTABLE REQUIRE TEC
#37023780M
Feb 9, 2023
POP/IN-VIO
$0
Dec 2, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #900750.REMEDY:SUBMIT ACCEPTABLE REQUIRE TEC
#37023747K
Feb 9, 2023
POP/IN-VIO
$0
DOB (5)
IssuedViolationStatus
Oct 28, 2024CONSTRUCTION
PARTIAL VACATE ORDER AT EXPOSURE #3, WEST ELEVATION PLAYGROUND AREA DUE TO HAZARDOUS CONDITIONS OBSERVED SUCH AS LOOSE/SPALLING CONCRETE AT PARAPET LEVEL, DIRECTLY ABOVE PLAYGROUND. REMEDY: VACATE ENTIRE PLAYGROUND AREA AT EXP 3, WEST ELEVATION
#LL0304SB
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00072
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00073
DOB VIOLATION - ACTIVE
Jan 31, 2018FACADE SAFETY PROGRAM

#HAZ77126
DOB VIOLATION - ACTIVE
Jan 31, 2018FACADE SAFETY PROGRAM

#HAZ87127
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Jan 31, 2018Facades FISP
CYCLE 7A UNSAFE REPORT FILED
Active
Jan 31, 2018Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
HPD (6) · C 0 · B 6 · A 0
IssuedClassViolationCorrect by
Sep 25, 2026B§ 27-2005 HMC: REFIT THE BUILDING FRONT ENTRANCE DOOR , 1st STORY, SECTION ''643''Oct 30, 2026
Sep 25, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT THE PUSHBAR OF THE BUILDING FRONT ENTRANCE DOOR , 1st STORY, SECTION ''641''Oct 30, 2026
May 26, 2026BApt 11E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 11E, 11th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''B'', 2nd FROM NORTH AT EASTJun 30, 2026
May 26, 2026BApt 11E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING AND SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 11E, 11th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''B'', 2nd FROM NORTH AT EASTJun 30, 2026
May 26, 2026BApt 11E · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11E, 11th STORY, 1st APARTMENT FROM NORTH AT EAST , SJun 30, 2026
May 26, 2026BApt 11E · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11E, 11th STORY, 1st APARTMENT FROM NORTH AT EAST ,Jun 30, 2026

Issued in the last 120 days

DateSourceWhatNow
Sep 25, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT THE BUILDING FRONT ENTRANCE DOOR , 1st STORY, SECTION ''641''Closed
Sep 25, 2026HPD B§ 27-2005 HMC: REFIT THE BUILDING FRONT ENTRANCE DOOR , 1st STORY, SECTION ''643''Open
Sep 25, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT THE PUSHBAR OF THE BUILDING FRONT ENTRANCE DOOR , 1st STORY, SECTION ''641''Open
Sep 25, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE CLOSER ARM AT THE BUILDING FRONT ENTRANCE DOOR , 1st STORY, SECTION ''643''Closed
Aug 11, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR , 1st STORYClosed
Aug 11, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND ASSEMBLIES, AT BUILDING ENTRANCE DOOR , 1st STORYClosed
Aug 11, 2026HPD C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF MAGNETIC DOOR STOP INSTALLED AT FLOOR, AT FIRE DOOR LEADING TO STAIRCASE A AT PUBLIC HALL, 1st STORYClosed
Jul 31, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR LEADING TO STAIRCASE A AT PUBLIC HALL STAIRS, 5th STORYClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 9:51 PM ET. BBL 1003960010.

Look up another building