Brooklyn · Block 5717 · Lot 1 · 11219

6013 11 Avenue

1 floors · 8,800 sq ft · built 1994 · class K1 · owner of record: M.K.V., Llc

6open violations
$10,625ECB/OATH penalties owed
0HPD class C (immediately hazardous)
428dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 428 days
Next cycle year 2027

Open violations

ECB / OATH (5) · $10,625 owed
IssuedViolationHearingBalance
Sep 12, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING FIRE SUPPRESSION SYSTEM IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED MULTIPLE SPRINKLER HEADS THROUGHOUT PREMISES PARTIALLY COVERED/ OBSTRUCTED BY A TYPE OF FABRIC MAT
#39203880K
Nov 25, 2026
PENDING
$2,500
Sep 12, 2026Construction CLASS - 1
FAILURE TO MAINTAIN THE REQUIRED FIRE-RESISTANCE-RATED SEPARATION BETWEEN THE BOILER ROOM AND ELECTRICAL ROOM. OBSERVED MULTIPLE UNSEALED AND IMPROPERLY SEALED PENETRATIONS AT THE WALL/CEILING ASSEMBLY AROUND P
#39203883X
Nov 25, 2026
PENDING
$2,500
Sep 12, 2026Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. NOTED: FAILURE TO MAINTAIN REQUIRED EXIT DOOR WITH COMPLIANT EGRESS HARDWARE AT EXP#04. OBSERVED EXIT DOOR EQUIPPED WITH LOCKING HARDWARE REQUIRING GRASPING, TWISTING, OR SPECIAL OPE
#39203884H
Nov 25, 2026
PENDING
$625
Sep 12, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR WALL IN A CODE-COMPLIANT. OBSERVED MULTIPLE MISSING, CRACKED AND DAMAGED EXTERIOR FACADE TILES, EXPOSING THE UNDERLYING WALL/MORTAR. ALSO OBSERVED MULTIPLE CRACKS AND DETER
#39203882Y
Nov 25, 2026
PENDING
$2,500
Sep 12, 2026Construction CLASS - 1
OBSERVED PREMISES OCCUPIED BY MORE THAN 120 PERSONS, WITH CEILING HEIGHT LESS THAN 16 FEET, AND UTILIZED FOR ASSEMBLY/ENTERTAINMENT WITH AMPLIFIED SOUND SYSTEM AND DANCING, CONTRARY TO THE APPROVED CERTIFICATE
#39203881M
Nov 25, 2026
PENDING
$2,500
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 12, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING FIRE SUPPRESSION SYSTEM IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED MULTIPLE SPRINKLER HEADS THROUGHOUT PREMISES PARTIALLY COVERED/ OBSTRUCTED BY A TYPE OF FABRIC MATOpen
Sep 12, 2026ECBConstruction: FAILURE TO MAINTAIN THE REQUIRED FIRE-RESISTANCE-RATED SEPARATION BETWEEN THE BOILER ROOM AND ELECTRICAL ROOM. OBSERVED MULTIPLE UNSEALED AND IMPROPERLY SEALED PENETRATIONS AT THE WALL/CEILING ASSEMBLY AROUND POpen
Sep 12, 2026ECBConstruction: EXIT DOOR NOT SELF-CLOSING. NOTED: FAILURE TO MAINTAIN REQUIRED EXIT DOOR WITH COMPLIANT EGRESS HARDWARE AT EXP#04. OBSERVED EXIT DOOR EQUIPPED WITH LOCKING HARDWARE REQUIRING GRASPING, TWISTING, OR SPECIAL OPEOpen
Sep 12, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING EXTERIOR WALL IN A CODE-COMPLIANT. OBSERVED MULTIPLE MISSING, CRACKED AND DAMAGED EXTERIOR FACADE TILES, EXPOSING THE UNDERLYING WALL/MORTAR. ALSO OBSERVED MULTIPLE CRACKS AND DETEROpen
Sep 12, 2026ECBConstruction: OBSERVED PREMISES OCCUPIED BY MORE THAN 120 PERSONS, WITH CEILING HEIGHT LESS THAN 16 FEET, AND UTILIZED FOR ASSEMBLY/ENTERTAINMENT WITH AMPLIFIED SOUND SYSTEM AND DANCING, CONTRARY TO THE APPROVED CERTIFICATEOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 10:47 AM ET. BBL 3057170001.