6 floors · 22 apartments · 11,469 sq ft · built 1900 · class C7 · owner of record: 60 Avenue B Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-03 (Accepted). Agency page | Dec 31, 2026 in 66 days | 2 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 29, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTED AT TIME OF INSPECTION AT EXPOSURE #1 ON AVENUE B, 5TH FLOOR WINDOWS MISSING AIR CONDITIONING UNIT BRACKETS(IMPROPELY SUPPORTED). CREATING HAZARDOUS CON #35725779Z | Apr 9, 2026 DEFAULT | $10,000 |
| Oct 30, 2025 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NO CERTIFICATE OF CORRECTION ON FILE AS PER REQUEST OF COMMISSIONER FOR CLASS 1 WORK WITHOUT A PERMIT VIOLATION #35646793J ISSUED ON 03/27/2023 FOR A #35693409H | Jan 8, 2026 DEFAULT | $12,500 |
| Feb 28, 2025 | Boilers CLASS - 2 OBSERVED HB SMITH STEAM BOILER MODEL #HB-19HE-7, THAT THE STEAM PIPE WERE BANGING WHILE THE BOILER WAS RUNNING. CORRECT VIOLATING CONDITIONSAND SUBMIT A CERTIFICATE OF CORRECTION. #39139947M | May 8, 2025 DEFAULT | $6,250 |
| Aug 2, 2023 | Unknown CLASS - 3 A8 ELECTRICAL WORK WITHOUT A PERMIT. INSTALLATION OF 600 AMPS SERVICE SWITCH IN BASEMENT, 500MCM SERVICE CONDUCTORS, IN BASEMENT. LIVE TEMPORARY WIRES EXPOSED IN BASEMENT. NOT COVERED UNDER APPLICATION #M356545 #39091651N | Oct 12, 2023 DEFAULT | $500 |
| Mar 27, 2023 | Construction CLASS - 1 WORK WITHOUT A PERMIT.NOTE AT TIME OF INSPECTION AT ABOVE PREMISES OBSERVED ON APT4B ON 4TH FLOOR A FULL GUT RENOVATION.NEW ELECTRICAL PANELSWITCHES,OUTLETS AND NEW LIGHTING,NEW PLUMBING FOR BATHROOM.NEW CONSTR #35646793J | Nov 14, 2024 IN VIOLATION | $2,500 |
| Nov 1, 2019 | Construction CLASS - 1 AT TIME OF INSPECTION NOTICED THAT FIRE STOPPING WAS REMOVED FROM CEILING AND PARTY WALL., PROVIDE/MAINTAIN FIRE STOPPING; COMPLY WITH VIOLATION. #39012225M | Dec 19, 2019 DEFAULT | $12,500 |
| Issued | Violation | Status |
|---|---|---|
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00078 | DOB VIOLATION - ACTIVE |
| Nov 13, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00009 | DOB VIOLATION - ACTIVE |
| Jul 25, 2019 | CONSTRUCTION FTM:RETAINING WALL@EXP3 REAR LOT LINE IN DISREPAIR.MISSING STONES,MASN WALL OF EXTN CRACKED LEANING INTO REAR YARD. LOOSE BRICKS FROM DAMAGED EXTN@RISK OF FALLING INTO REAR YARD.RETAINING&EXTN WALL ARE AT RISK OF COLLAPSING INTO REAR YARD OF 60 AVE B. PARTIAL VACATE OF REAR YARD TIL UNSAFE CONDN OF #FEU10301IK | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 13, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 28, 2023 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 6th STORY | Dec 1, 2023 |
| Jan 27, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE :BULKHEAD DOOR , 6th STORY | Feb 10, 2023 |
| Dec 5, 2022 | C | Apt 1C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 4, 2022 |
| Apr 20, 2022 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD DECK AND 2 BULKHEADS ERECTED AT FRONT ROOF | Jul 24, 2022 |
| Aug 7, 2020 | C | Apt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 2, 2020 |
| Aug 7, 2020 | B | Apt 1A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 20 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 11, 2020 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 8:30 PM ET. BBL 1004000038.