17 floors · 80,185 sq ft · built 1913 · class H3 · owner of record: New 6 West 32nd Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 51 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 80,185 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 172 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 172 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1147 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 833). Agency page | Dec 31, 2033 in 2608 days | Next due 2033 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-25 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $199,500 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: SAFE (2025-08-28) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 3, 2026 | Construction CLASS - 1 ATOI OBSERVED IN THE BASEMENT LACK OF SPRINKLER COVERAGE IN A OPEN AREA ROOM CONTAINING GARBAGE BINSBC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLERS BE POSITIONED #39202967Z | Nov 12, 2026 PENDING | $2,500 |
| Sep 3, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS AND PLASTIC ACCESS PANELS, WHICH ARE NOT RATED. POTENTIAL FIRE HAZARD. LOCATED THROUGHOUT BASEMENT LEVEL., REPAIR AND/REPLACE #39202969M | Nov 12, 2026 PENDING | $2,500 |
| Jul 20, 2026 | Construction CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39125617M ISSUED ON 09-23-2024 FOR UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIAL S, DEVICES, APPLIANCES OR WIRING IN USE., FILE #39196742J | Sep 24, 2026 IN VIOLATION | $1,250 |
| Dec 5, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: PROVIDE UPDATED MAINTENANCE LOG. PROVIDE TO INSTALL GUARD FOR DEFLECTOR SHEAVE. SECURE SITE GUARD ON LOBBY DOOR. REMOVE LUBRICATION FROM GUIDE ROLLER & RAIL AT TOP OF CAR. #39169464P | Aug 7, 2026 IN VIOLATION | $625 |
| Dec 5, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: PROVIDE UPDATED MAINTENANCE LOG. FIRE FIGHTER SERVICE PHASE 1 & 2 KEY SWITCHES NEED LABELING. PROVIDE TO INSTALL GUARD ON DEFLECTOR SHEAVE. PROVIDE TO SECURE SITE GUARD ON LOBBY DOOR. CLEAN ENTIR #39169465R | Aug 7, 2026 IN VIOLATION | $625 |
| Sep 23, 2024 | Construction CLASS - 2 NO VENTILATION OBSERVED IN THE GAS METER ROOM HOUSING THE WATER METER AND BOOSTER PUMP. AS PER APPENDIX E 4 OF THE FGC GAS METER ROOMS SHALLBE PROPERLY VENTILATED., REPAIR AND/OR REPLACE #39125597Y | Jan 2, 2025 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 13, 2004 | ELEVATOR #9013/192134 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 7, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 7, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 7, 2026 | DOB Safety | AEUHAZ: | Open |
| Oct 7, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 3, 2026 | ECB | Construction: ATOI OBSERVED IN THE BASEMENT LACK OF SPRINKLER COVERAGE IN A OPEN AREA ROOM CONTAINING GARBAGE BINSBC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLERS BE POSITIONED | Open |
| Sep 3, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS AND PLASTIC ACCESS PANELS, WHICH ARE NOT RATED. POTENTIAL FIRE HAZARD. LOCATED THROUGHOUT BASEMENT LEVEL., REPAIR AND/REPLACE | Open |
| Jul 20, 2026 | ECB | Construction: FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39125617M ISSUED ON 09-23-2024 FOR UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIAL S, DEVICES, APPLIANCES OR WIRING IN USE., FILE | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)