Brooklyn · Block 1475 · Lot 4 · 11233

599 Ralph Avenue

4 floors · 52,100 sq ft · built 1921 · class N9 · owner of record: 599 Ralph Avenue Deve

8open violations
$5,090ECB/OATH penalties owed
0HPD class C (immediately hazardous)
67dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 67 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 52,100 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1475). Agency page

Dec 31, 2035
in 3354 days
Next due 2035
Annual boiler inspection (5 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-13 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7) · $5,090 owed
IssuedViolationHearingBalance
Apr 30, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIOONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39134996X, FILE A CERTIFICATE OF CORRECTION
#39186702X
Jul 8, 2026
DEFAULT
$0
Nov 7, 2025Elevators CLASS - 1
CLASS 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. FOR A REINSPECTION. CLASS 2
#39166304M
Dec 10, 2026
DEFAULT
$1,280
Jan 9, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED UNPERMITTED PLASTIC ACCESS PANEL. ACCESS PANEL NO FIRE RATED. HOLE PENET
#39134996X
Oct 29, 2026
$2,530
Jan 9, 2025Construction CLASS - 2
I OBSERVED IN THE 5TH FLOOR BOILER ROOM AT THE POINT OF EGRESS LEADING TO THE FIFTH FLOOR ROOF NO REMOTE SHUT-DOWN FOR THE BOILERS AS REQUIRED IN MC 1006.8.1. PHOTOS TAKEN. (PLEASE NOTE A SWITCH IS REQUIRED AT
#39135001N
Oct 29, 2026
$1,280
Nov 28, 2023Construction CLASS - 2
OBSERVED IN THE BOILER ROOM LOCATED ON 5TH FLOOR EXCESSIVE LEAK ON PUMP. AS PC 102.3 MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING CONDITION IN ACC
#39100235X
Jul 29, 2024
IN VIOLATION
$0
Jun 27, 2023Boilers CLASS - 3
FRONT BOILER JACKET NOT IN PLACE/DOMESTIC WATER RELIEF VALVES NOT PIPED DOWN;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION
#39089214M
Feb 2, 2024
IN VIOLATION
$0
Jun 27, 2023Boilers CLASS - 2
POOR FLAME FROM BURNERS/IGNITION CONTROL UNIT DEFECTIVE/FRONT BOILER JACKET NOT IN PLACE;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION
#39089215Y
Feb 2, 2024
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#26328
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#26329
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 3:09 PM ET. BBL 3014750004.