1 floors · 2,400 sq ft · built 1930 · class M1 · owner of record: Metro New York District Church Of The Na Zarene
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-04-23 (Accepted). Agency page | Dec 31, 2026 in 68 days | 1 of 1 without an accepted 2026 report yet |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 799 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 23, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS # 39129728N., FILE A CERTIFICATE OF CORRECTION #39171277M | May 3, 2027 DEFAULT | $6,250 |
| Aug 26, 2025 | Unknown CLASS - 1 AT THE TIME OF INSPECTION I OBSERVED FACADE REPAIR AT ROOF LEVEL, ON CHURCH AT EXPOSURE#2,4 WITH WORN /DEFECTIVE ROPE LANYARDS IN USE AND NOT PROPERLY SECURED CREATING A POTENTIAL FALL HAZARD FOR WORKERS ON SIT #39544122R | Oct 15, 2026 DEFAULT | $5,000 |
| Nov 7, 2024 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED AT CELLAR LEVEL EXIT PASSAGEWAY OBSTRUCTED BY COMBUSTIBLE MATERIALS AND HOUSEHOLD ITEMS., REPAIR AND/OR REPLACE #39129729P | Jan 7, 2027 PENDING | $655 |
| Nov 7, 2024 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED EXP#2,3,AND 4 WALL HAVE CRACKS AT MULTIPLE LOCATIONS, EXP#2 AND 4 WALL BULGING. ALSO AT EXP#4 FRAMING BEAM DISPLACED PUSHING BRICK WALL OUTWARD., MAINTAIN EXTERIOR BUILDING WALL #39129728N | Jan 7, 2027 PENDING | $2,530 |
| Issued | Violation | Status |
|---|---|---|
| Nov 7, 2024 | CONSTRUCTION FAILURE TO MAINTAIN.BLDG SFFRD A FIRE ON 11/3/24&ONE ROOF TRUSS CHORD WAS FIRE DMGD.UNRELATD TO FIRE,TRUSS BOTTOM CHRDS/TIES FRM EXP2(NORTH) TO EXP4(SOUTH)WERE PREV REMOVD.EXP2&4 WALLS LEANING.1.NYSPE STRCTRL ENG TO IMMED EVAL THE ENT BLDG&DSGN RPAIRS,2.FILE FOR RPAIRS BY 3/10/25,3.OBTN PRMTS&STRT W #FEU30302BS | DOB VIOLATION - ACTIVE |
| Nov 7, 2024 | CONSTRUCTION EMERGENCY WORK.BLDG SFFRD A FIRE ON 11/3/24.UNRELATED TO FIRE, HORIZONTL BEAMS PREV RMVD@TRUSS LOCATIONS.EXP2(NORTH)&EXP4(SOUTH)WALLS LEANING OUTWRD@TOP.OBSRVD DTERIORATD WOOD FRAMNG@EMBEDDED INEXP2 1.IMMED INSTLL TEMP SHORNG&BRACNG&TEMP HORIZONTL BEAMS@DIRECTN OF NYSPE STRCTRL ENG,2.ALL WRK TO BE D #FEU30301BS | DOB VIOLATION - ACTIVE |
| Nov 7, 2024 | CONSTRUCTION STRUCTURE RENDERED NON COMPLAINT. OBSERVED SECTION OF TIE BEAM CHARRED WHICH SUPPORTING METAL RODS PARTIALLY ROOF AND EXP#2 AND 4 WALL .DUE TO FIRE. VACATE ENTIRE BUILDING. #24-02916 | DOB VIOLATION - ACTIVE |
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #08717 | DOB VIOLATION - ACTIVE |
| Jan 1, 2009 | LOCAL LAW 62/91 - BOILERS #16581 | DOB VIOLATION - ACTIVE |
| Feb 13, 2004 | LOCAL LAW 62/91 - BOILERS #18909 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #16949 | DOB VIOLATION - ACTIVE |
| Mar 26, 2002 | LOCAL LAW 62/91 - BOILERS #18231 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #24074 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #32416 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| Jan 1, 2009 | Boiler LL6291 | Active |
| Feb 13, 2004 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 26, 2002 | Boiler LL6291 | Active |
| May 4, 1998 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 9:55 AM ET. BBL 3020200006.