7 floors · 76 apartments · 52,801 sq ft · built 1960 · class D1 · owner of record: Mattioli Family Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 52 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 52 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 68 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 52,801 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 173 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 173 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 296 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $106,500 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 469 days | No Cycle 10 report on record yet |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 783 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6068). Agency page | Dec 31, 2028 in 783 days | Next due 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-22 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jul 16, 2021 | HAZARDOUS CONDITION (FACADE) CYCLE 8B UNSAFE REPORT FILED #809578 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #05793 | DOB VIOLATION - ACTIVE |
| Aug 30, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 #01570 | DOB VIOLATION - ACTIVE |
| Oct 8, 2010 | ELEVATOR ANNUAL INSPECTION / TEST #04377 | DOB VIOLATION - ACTIVE |
| Jan 3, 2008 | LOCAL LAW 62/91 - BOILERS #10825 | DOB VIOLATION - ACTIVE |
| Nov 30, 2007 | LOCAL LAW 11/98 - FACADE #NRF45993 | DOB VIOLATION - ACTIVE |
| Jan 6, 2006 | LOCAL LAW 62/91 - BOILERS #10823 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 16, 2021 | Facades FISPHAZ CYCLE 8B UNSAFE REPORT FILED | Active |
| Jul 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018 | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
| Aug 30, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 | Active |
| Oct 8, 2010 | Elevators VCAT1 | Active |
| Jan 3, 2008 | Boiler LL6291 | Active |
| Nov 30, 2007 | Facades LL1198 CYCLE 6 NO REPORT FILED | Active |
| Jan 6, 2006 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 8, 2025 | C | Apt 2E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 4th APARTMENT FROM SOUTH AT WEST | Jun 3, 2025 |
| Jan 30, 2023 | B | Apt 1J · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE AT SINK IN THE KITCHEN LOCATED AT APT 1J, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 6, 2023 |
| Jan 30, 2023 | B | Apt 1J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET AT SINK IN THE KITCHEN LOCATED AT APT 1J, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 6, 2023 |
| Jan 30, 2023 | C | Apt 1J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Feb 25, 2023 |
| Jan 30, 2023 | B | Apt 1J · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 1J, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 6, 2023 |
| Jan 30, 2023 | B | Apt 1J · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND RETURN BUZZER SYSTEM FROM VESTIBULE BUILDING TO EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1J, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 6, 2023 |
| Jan 30, 2023 | B | Apt 1J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE BATHROOM LOCATED AT APT 1J, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 6, 2023 |
| Sep 14, 2020 | B | Apt 6E · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS GANGE IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 19, 2020 |
| Aug 27, 2020 | C | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS AT SOUTH ENTRANCE LEADS TO STAIRS AT PUBLIC HALL, 6th STORY | Sep 22, 2020 |
| Mar 16, 2020 | C | Apt 2J · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 2nd APA | Apr 13, 2020 |
| Feb 3, 2020 | C | Apt 2J · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 2nd APA | Mar 2, 2020 |
| Nov 20, 2019 | C | Apt 2J · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 2nd APA | Dec 18, 2019 |
| Nov 20, 2019 | C | Apt 2J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Dec 11, 2019 |
| Sep 12, 2018 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRIC OUTLET SAFETY CAPS ON THE NORTH WALL AT PUBLIC HALL, 1st STORY | Oct 17, 2018 |
| Aug 13, 2018 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL | Nov 16, 2018 |
| Aug 13, 2018 | B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS EAST STACK AT BUILDING FRONT | Sep 17, 2018 |
| Aug 8, 2018 | A | Apt 1I · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1I, 1st STORY | Nov 11, 2018 |
| Aug 8, 2018 | A | Apt 1I · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 1I, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 11, 2018 |
| Feb 28, 2018 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING ON WALL AT PUBLIC HALL, 1st STORY | Mar 8, 2018 |
| Mar 13, 2017 | B | Apt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH | Apr 17, 2017 |
| Mar 13, 2017 | B | Apt 1F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BASE CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH | Apr 17, 2017 |
| Mar 13, 2017 | B | Apt 1F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WALL CABINET AT EAST WALL IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH | Apr 17, 2017 |
| Mar 13, 2017 | B | Apt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH | Apr 17, 2017 |
| Apr 14, 2016 | B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS .. AT 1st FIRE ESCAPE FROM NORTH AT WEST | May 19, 2016 |
| Jan 20, 2015 | C | Apt 1A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 3; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 1A, 1st STORY, 4th APARTMENT FROM WEST AT NORT | Feb 17, 2015 |
| Jan 20, 2015 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM TO BOILER ROOM AT BASEMENT | Jan 28, 2015 |
| Jul 5, 2013 | C | Apt 5C · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORT | Aug 2, 2013 |
| Jul 2, 2013 | B | Apt 6C · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, APARTMENT AT EAST | Aug 6, 2013 |
| Mar 1, 2013 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT VESTIBULE DOOR AT PUBLIC HALL | Mar 7, 2013 |
| Mar 1, 2013 | B | § 27-2005 ADM CODE PROVIDE (IN THE EVENT OF A POWER OUTAGE) AN ACCEPTABLE HEAVY DUTY LOCK AND LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL | Apr 5, 2013 |
| Jan 7, 2013 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Jan 13, 2013 |
| Sep 20, 2012 | B | Apt L3 · § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS .... IN THE ENTRANCE LOCATED AT APT L3, 2nd APARTMENT FROM SOUTH AT WEST | Oct 25, 2012 |
| Sep 20, 2012 | B | Apt L3 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK IN THE ENTRANCE LOCATED AT APT L3, 2nd APARTMENT FROM SOUTH AT WEST | Oct 25, 2012 |
| Aug 14, 2012 | A | Apt L3 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN THE BATHROOM LOCATED AT APT L3, 2nd APARTMENT FROM NORTH AT EAST | Nov 17, 2012 |
| Oct 13, 2010 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT STREET ENTRANCE DOOR | Oct 19, 2010 |
| Sep 27, 2010 | A | Apt L3 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT L3, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Dec 31, 2010 |
| Jun 8, 2010 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATING LOCK INSTALLED AT BUILDING ENTRANCE DOOR , 1st STORY | Jun 14, 2010 |
| Jan 15, 1991 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT DOOR VESTIBULE TO 1 STY PUBLIC HALL | Feb 4, 1991 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)