3.5 floors · 25,505 sq ft · built 1946 · class M1 · owner of record: St Marks Meth Epis Ch
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-16 (Accepted). Agency page | Dec 31, 2026 in 66 days | 2 of 2 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 25,505 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 9, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS IN A CODE COMPLAINT MANNER. NOTED: BUILDING EXTERIOR WALLS IN DISREPAIR AND DETERIORATED WITH CRACKED DECORATIVE MASONRY ARCH ABOVE EXPOSURE # 1 AND # 4 ENTRANCE DOOR #39037325K | Apr 29, 2021 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #42233 | DOB VIOLATION - ACTIVE |
| May 16, 2022 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. ACCESS PROVIDED TO SANCTUARY NOTED PLASTER / MORTAR / STUCCO ACTIVELY RELEASING FROM TERRA-COTTA PERIMETER EXTERIOR WALLS AND FALLING TO INTERIOR SANCTUARY AREA CREATING AN IMMEDIATELY HAZARDOUS CONDITION FOR SANCTUARY OCCUPANTS. #22-01392 | DOB VIOLATION - ACTIVE |
| Dec 1, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2101097 | DOB VIOLATION - ACTIVE |
| Jun 9, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00099 | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2001396 | DOB VIOLATION - ACTIVE |
| Jul 25, 2020 | CONSTRUCTION DUE TO VEHICLE STRIKING SIDEWALK SHED DISPLACING ONE COLUMN & 1 CROSS BRACE #CER04LP | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Dec 1, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Jun 9, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 4, 2010 | B | Apt 6C · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 9, 2010 |
| Jun 4, 2010 | A | Apt 6C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WALLS IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 7, 2010 |
| Jun 4, 2010 | B | Apt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 9, 2010 |
| Jun 4, 2010 | B | Apt 6C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK AT THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 9, 2010 |
| Jun 4, 2010 | A | Apt 6C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT THE ENTRANCE IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 7, 2010 |
| Jun 4, 2010 | B | Apt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 9, 2010 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 8:43 PM ET. BBL 1020480001.