1 floors · 10,000 sq ft · built 1950 · class K1 · owner of record: The Grandview Of Queens Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1159 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 29, 2024 | Construction CLASS - 2 OBSVD 1 STR BLDG UNDER ALTERATION- ACTIVE SITE- WITH WORK FILED UNDER PERMIT/APP # Q01044414 HAVING BEEN STARTED. ALSO OBSVD ROOF PARAPET BEING ALTERED / EXTENDED. UPON REQUEST, THE FOLLOWING DOCS WERE NOT PROV #39533959P | Jun 10, 2025 IN VIOLATION | $1,250 |
| Oct 29, 2024 | Unknown CLASS - 2 BC 3307.1 PROTECTION OF PEDESTRIANS. OBSERVED 1 STR BLDG UNDER ALTERATION W/ UNFINISHED AND ACTIVE WORK ON THE ROOF PARAPET AT EXPS# 1, 2 & 4 AS WELL AS ACTIVE FACADE WORK ON A SCAFFOLD AT EXP#1 AND ON A SCISSO #39533960M | Jun 10, 2025 IN VIOLATION | $2,500 |
| Oct 29, 2024 | Unknown CLASS - 2 BC 3303.7.2 FIRE EXTINGUISHERS. OBSERVED 1 STR + CEL BLDG UNDER ALTERATION WITH ALL OF THE FIRE EXTINGUISHERS ON SITE HAVING EXPIRED ANNUAL INSPECTION/SERVICE TAGS, AND MULTIPLE EXTINGUISHERS PLACED ON THE GROU #39533962X | Mar 4, 2025 IN VIOLATION | $2,500 |
| Oct 29, 2024 | Unknown CLASS - 2 BC 3314.1 SCAFFOLDS. OBSERVED 1 STR BLDG. UNDER ALTERATION WITH SUPPORTED SCAFOLD IN PLACE AT EXP# 1 & 4 WITH MISSING GUARD RAILS / END RAILS / TOEBOARDS. AND AN INTERIOR BAKER SCAFFOLD WITH INADEQUATE BRACING, #39533961Y | Mar 4, 2025 IN VIOLATION | $2,500 |
| Aug 29, 2024 | Construction CLASS - 1 ATOI OBSERVED OPENING APPROX 10FT X 15FT OF STRUCTURAL JOISTS AND CONCRETE SLAB REMOVED BETWEEN 1ST FLR DECK AND CELLAR. NO ADDITIONAL SUPPORT ADDED AT CELLAR, NO FALL PROTECTION SAFEGUARDS IN PLACE - STRUCTURE #39123569H | May 20, 2025 IN VIOLATION | $625 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 29, 2026, 12:16 AM ET. BBL 4033730001.