9 floors · 197 apartments · 158,893 sq ft · built 2022 · class D7 · owner of record: Sb Gerard Avenue, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 64 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 158,893 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 308 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 847 days | Filing window not open yet |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2353). Agency page | Dec 31, 2033 in 2621 days | Next due 2033 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 24, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED A SUSPENDED SCAFFOLD PLATFORM AT EXP. 3 CONTRARY TO SKY CLIMBER SPECIFICATIONS. PLATFORM TOTAL LENGTH IS 6 METERS WITH A CANTILEVER(OVERHANG) OF 3 METERS AS PER SPECS MAX CANTILEV #39545274K | Jun 12, 2026 IN VIOLATION | $1,250 |
| Sep 24, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED 2 SUSPENDED SCAFFOLDS AT EXP. 3. RIGGING CREW ON SITE INCLUDING FOREMAN. UPON REQUESTING THE FOLLOWING DOCUMENTS WERE NOT PROVIDED. PRE AND POST INSTALLATION LETTERS, NOTIFICATION #39545273Z | Jun 12, 2026 IN VIOLATION | $1,250 |
| Oct 6, 2024 | Construction CLASS - 1 DUE EXCAVATION UNDER ACTIVE JOB# X00687238 AT EXPOSURE# CAUSING DAMAGE TO THE FENCE AND CONCRETE SLAB AT NEIGHBORING PROPERTY (615 WALTON AVENUE) WHICH HAS BEEN VACATE AT PREVIOUS INSPECTION., SAFEGUARD PUBLIC #39126724M | Nov 6, 2026 DEFAULT | $12,500 |
| Oct 2, 2023 | Construction CLASS - 1 BC 1604.2 & BC 1806.2 DEFICIENT DESIGN-A FAILURE OF THE SUPPORT OF EXCAVATION(SOE)SYSTEM OCCURRED ON 3/10/2023.AS A RESULT A PEER REVIEW WASMANDATED UNDER COMMISSIONER'S ORDER#359311.THE REPORT CONFIRMED THAT T #35649831P | Aug 26, 2025 IN VIOLATION | $2,500 |
| Oct 2, 2023 | Construction CLASS - 1 BC 1604.2 & BC 1806.2 DEFICENT DESIGN-A FAILURE OF THE SUPPORT OF EXCAVATION(SOE)SYSTEM OCCURRED ON 3/10/23.A PEER REVIEW WAS MANDATED UNDERCOMMISSIONER'S ORDER#359311.THE REPORT CONFIRMED THAT THE RESPONDENT,S #35649830N | Aug 26, 2025 IN VIOLATION | $2,500 |
| Oct 2, 2023 | Construction CLASS - 1 BC 1604.2 & BC 1806.2 DEFICIENT DESIGN-A FAILURE OF THE SUPPORT OF EXCAVATION(SOE)SYSTEM OCCURRED ON 3/10/23 A PEER REVIEW WAS MANDATED UNDER COMMISSIONER'S ORDER#359311.THE REPORT CONFIRMED THAT THE RESPONDENT #35649834K | Aug 26, 2025 IN VIOLATION | $2,500 |
| Oct 2, 2023 | Construction CLASS - 1 BC 3304.2 DEFICIENT SUPPORT OF EXCAVATION(SOE)DRAWINGS-A FAILURE OF THE SOE SYSTEM OCCURRED ON 3/10/23.AS A RESULT A PEER REVIEW WAS MANDATED UNDER COMMISSIONER'S ORDER#359311.THE REVIEW REVEALED THAT THE RESPO #35649835M | Aug 26, 2025 IN VIOLATION | $2,500 |
| Oct 2, 2023 | Construction CLASS - 1 BC 1604.2 & BC 1806.2 DEFICIENT DESIGN-A FAILURE OF THE SUPPORT OF EXCAVATION(SOE)SYSTEM OCCURRED ON 3/10/23.A PEER REVIEW WAS MANDATED UNDER COMMISSIONER'S ORDER#359311.THE REPORT CONFIRMED THAT THE RESPONDENT #35649832R | Aug 26, 2025 IN VIOLATION | $2,500 |
| Oct 2, 2023 | Construction CLASS - 2 AC 28-104.7.1 DEFICIENT SUPPORT OF EXCAVATION(SOE)DRAWINGS-A FAILURE OF THE SOE SYSTEM OCCURRED ON 3/10/23.AS A RESULT A PEER REVIEW WAS MANDATED UNDER COMMISSIONER'S ORDER#359311.THE REVIEW REVEALED THAT THE R #35649836Y | Aug 26, 2025 IN VIOLATION | $1,250 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 10:36 AM ET. BBL 2023530001.